Monte Carlo simulation of the photon beam characteristics from medical linear accelerators

被引:9
|
作者
Kim, H. K. [1 ]
Han, S. J.
Kim, J. L.
Kim, B. H.
Chang, S. Y.
Lee, J. K.
机构
[1] Korea Inst Radiol & Med Sci, Natl Radiat Emergency Med Ctr, Seoul 139706, South Korea
[2] Korea Inst Nucl Safety, Nucl Emergency Preparedness, Taejon, South Korea
[3] Korea Atom Energy Res Inst, Dept Hlth Phys, Taejon, South Korea
[4] Hanyang Univ, Dept Nucl Engn, Seoul 133791, South Korea
关键词
MODEL; DISTRIBUTIONS;
D O I
10.1093/rpd/nci636
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The MCNPX code has been employed on a personal computer to calculate the dosimetric characteristics of the photon beams from the 6 MV Siemens MX2 and the 10 MV Varian Clinac 2100C linear accelerators. A model of the treatment head includes the major geometric structure within the beam path. The model was used to calculate the energy spectra of the photon beam, percentage depth dose and the dose profiles. The accuracy of the calculated results is examined by comparing them with the measured dose distributions for the two machines. The computed and measured depth dose curves agree to within 2% for all the depths beyond the build-up region for both treatment machines. The calculations agree to within 2% of the measured profiles within the 100-50% dose level. It has been found that the MCNPX code is an effective tool for simulating the clinical photon beam.
引用
收藏
页码:510 / 513
页数:4
相关论文
共 50 条
  • [41] A study on scattered particles from medical linear accelerator head using monte carlo simulation
    Katayose, T. (u5856601@gs.metro-hs.ac.jp), (KEK High Energy Accelerator Research Organization):
  • [42] Monte Carlo calculations of electron beam output factors for a medical linear accelerator
    Kapur, A
    Ma, CM
    Mok, EC
    Findley, DO
    Boyer, AL
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12): : 3479 - 3494
  • [43] Determination of photon quantity in Monte Carlo simulation
    Xue Yang
    Gang Li
    Ling Lin
    Optical and Quantum Electronics, 2016, 48
  • [44] Accelerating photon transport in Monte Carlo simulation
    Ogawa, K
    Takahashi, S
    Satori, Y
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1147 - 1151
  • [45] Determination of photon quantity in Monte Carlo simulation
    Yang, Xue
    Li, Gang
    Lin, Ling
    OPTICAL AND QUANTUM ELECTRONICS, 2016, 48 (09)
  • [46] Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Boukhal, H.
    Saeed, M.
    Ahmed, Abdul-Aziz
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 69 - 75
  • [47] ELECTRON BEAM MATCHING FOR MEDICAL LINEAR ACCELERATORS
    Behrens, C.
    Bjelkengren, U.
    Ottosson, W.
    Sjostrom, D.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S384 - S385
  • [48] Beam spot motion of medical linear accelerators
    Yeboah, C
    Challacombe, J
    Pang, G
    O'Brien, P
    MEDICAL PHYSICS, 2005, 32 (07) : 2411 - 2411
  • [49] Benchmarking of electron beam parameters based on Monte Carlo linear accelerator simulation
    Zhang, Fan
    Zhou, Mi
    Liu, Jing
    Yue, Lu
    Deng, Lihua
    Xu, Zhijian
    Wang, Gang
    TRANSLATIONAL CANCER RESEARCH, 2020, 9 (02) : 577 - 584
  • [50] DETERMINATION OF PRIMARY ELECTRON BEAM PARAMETERS IN MONTE CARLO SIMULATION OF MEDICAL LINAC
    Vaezzadeh, S. A.
    Allahverdi, M.
    Nedaie, H. A.
    Yarahmadi, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S518 - S518