On the Possibility of Using Medical Linear Electron Accelerators as a Source of the Reference Pulsed Photon Radiation Field

被引:0
|
作者
Zaharadniuk, A. A. [1 ]
Taraev, A. Y. [1 ]
Lazarenko, S. V. [1 ]
机构
[1] SPE ATOMTEX, Gikalo Str, 5, Minsk 220005, BELARUS
来源
DEVICES AND METHODS OF MEASUREMENTS | 2023年 / 14卷 / 03期
关键词
Monte Carlo modelling; linear electron accelerator; pulsed photon radiation;
D O I
10.21122/2220-9506-2023-14-3-179-190
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Sources of pulsed photon radiation are widely used in science and industry. In this regard, there is a growing demand for dosimetry instruments capable of operating in these pulsed photon radiation fields. Until now there is no comprehensive methodology that describes the characteristics of reference fields of pulsed photon radiation required for calibration and verification of dosimetry equipment. The aim of this paper was to study the possibility of using a medical linear electron accelerator as a generating source of a reference pulsed photon radiation field. The paper investigates main characteristics of photon radiation field (namely, spectrum and average energy) generated by CLINAC in two modes of operation: 6 MV and 18 MV. Additionally it researches the possibility of attenuation of the CLINAC photon radiation intensity by a lead filter. The spectrum and average energy of the CLINAC photon radiation were calculated by means of Monte Carlo simulation in the Fluka program. The validation of the calculation was determined by comparing the attenuation coefficients calculated by the model with ones obtained experimentally by using real CLINACs. Experimentally, the attenuation coefficients were obtained by measuring the air kerma rate generated by the photon radiation fields of Varian VitalBeam and Varian iX CLINACs at a given point of space. Based on the simulation results, the H*(10) ambient dose equivalent ratio generated by CLINACs were calculated. It was found that the lead filter effectively attenuates the CLINAC photon radiation in terms of both air kerma rate and ambient dose equivalent rate to levels suitable for calibration of dosimetry equipment designed to measure pulsed radiation. It is shown that the lead filter significantly affects both the photon spectrum of the CLINAC and its average energy.
引用
收藏
页码:179 / 190
页数:12
相关论文
共 50 条
  • [21] Spectrometer for pulsed and continuous electron and photon radiation
    Behrens, R.
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 2012, 50 (07) : 450 - 453
  • [22] ELECTRON LINEAR ACCELERATORS IN FUNDAMENTAL RESEARCH IN RADIATION BIOLOGY
    KIEFER, J
    KERNTECHNIK, 1973, 15 (05) : 219 - 226
  • [23] HYPERFRACTIONATION - A NEW CHALLENGE TO MEDICAL ELECTRON LINEAR ACCELERATORS
    JENSEN, JM
    IHNEN, E
    GLASER, T
    HILLENBERG, HJ
    KOHR, P
    THOMS, M
    STRAHLENTHERAPIE UND ONKOLOGIE, 1990, 166 (06): : 415 - 419
  • [24] POSSIBLE MEDICAL AND INDUSTRIAL APPLICATION OF LINEAR ELECTRON ACCELERATORS
    BARBER, WC
    ELDREDGE, AL
    GINZTON, EL
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1953, 41 (03): : 422 - 422
  • [25] Novel reference radiation fields for pulsed photon radiation installed at PTB
    Klammer, J.
    Roth, J.
    Hupe, O.
    RADIATION PROTECTION DOSIMETRY, 2012, 151 (03) : 478 - 482
  • [26] Determination of Radiation Delivery Parameters of Medical Linear Accelerators using Data Analytics Pipeline
    Zubair, H. T.
    Tan, Yi-Fei
    Basaif, Azmi
    Oresegun, Adebiyi
    Zin, Hafiz
    Bradley, David
    Rashid, Hairul Azhar Abdul
    2022 IEEE-EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES, IECBES, 2022, : 40 - 45
  • [27] INTENSE SOURCE OF SLOW POSITRONS FROM PULSED ELECTRON-ACCELERATORS
    GRAFF, G
    LEY, R
    OSIPOWICZ, A
    WERTH, G
    AHRENS, J
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1984, 33 (01): : 59 - 62
  • [28] THE LINEAR ELECTRON ACCELERATOR AS A PULSED NEUTRON SOURCE
    FELD, BT
    NUCLEONICS, 1951, 9 (04): : 51 - 57
  • [30] A framework for failure prediction models of medical electron linear accelerators
    Medenou, Daton
    Idjiwole, Francois B. A.
    Houessouvo, Roland C.
    2019 IEEE AFRICON, 2019,