A novel control method for the automotive CO2 heat pumps under inappropriate refrigerant charge conditions

被引:7
|
作者
Jia, Fan [1 ]
Yin, Xiang [2 ]
Cao, Feng [1 ,2 ]
Fang, Jianmin [2 ]
Wang, Anci [2 ]
Wang, Xixi [3 ]
Yang, Lichen [3 ]
机构
[1] Xi An Jiao Tong Univ, Natl Innovat Platform Ctr Ind Educ Integrat Energy, 28 Xianning West Rd, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Peoples R China
[3] Yutong Bus Co Ltd, Zhengzhou 450061, Peoples R China
基金
中国国家自然科学基金;
关键词
CO 2 heat pumps; Refrigerant charge; Charge control; System simulation; PERFORMANCE; SYSTEM; MODEL; FLOW;
D O I
10.1016/j.energy.2023.129533
中图分类号
O414.1 [热力学];
学科分类号
摘要
CO2 heat pumps are increasingly widely used in automotive air conditioning, and the demand for refrigerant charge varies greatly under different modes and operation conditions. However, due to the limited space in vehicles, the accumulator cannot fully meet the refrigerant balance requirements for the variable operating conditions, and states of inappropriate refrigerant charge were frequently observed. To enhance system performance and safety under inappropriate charge conditions, an experimental setup and a mathematical model with a maximum error of 6 % were established to investigate the operating characteristics under inappropriate charge conditions. An investigation into the interplay among discharge pressure, the appropriate refrigerant charge range, and refrigerant distribution was conducted. It elucidated how refrigerant charging states (undercharged, adequately charged, or overcharged) manifest in terms of refrigerant distribution and optimal discharge pressure. A novel control method based on refrigerant distribution regulation has been proposed. The proposed control logic could increase the system IPLV by 36.8 % when the refrigerant charge deviates from the appropriate range by 12.12 %, and the greater the dysregulation in the refrigerant charge, the greater the improvement. This control logic would be more enhanced if dysregulation was considered.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] A comprehensive review of hydrogel performance under CO2 conditions for conformance control
    Sun, Xindi
    Bai, Baojun
    Long, Yifu
    Wang, Ze
    JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2020, 185
  • [42] Heat transfer performance of CO2, ethane and their azeotropic mixture under supercritical conditions
    Kravanja, Gregor
    Zajc, Gasper
    Knez, Zeljko
    Skerget, Mojca
    Marcic, Simon
    Knez, Masa H.
    ENERGY, 2018, 152 : 190 - 201
  • [43] METHOD OF MEASURING CO2 FLOW FROM SOIL UNDER NATURAL CONDITIONS
    IVANNIKOVA, LA
    EURASIAN SOIL SCIENCE, 1992, 24 (09) : 88 - 94
  • [44] Convective heat transfer of CO2 foam fracturing fluid under downhole conditions
    Wang, Shuzhong
    Wang, Bin
    Lin, Zonghu
    Wang, Zhigang
    Zhang, Aizhou
    Zan, Yuanfeng
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2004, 55 (03): : 468 - 471
  • [45] Research of The CO2 Heat Pump System for Automotive Air Conditioning
    He Zhebin
    Lv Jing
    Yang Dazhang
    Huang Xiuzhi
    ICEET: 2009 INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENT TECHNOLOGY, VOL 1, PROCEEDINGS, 2009, : 275 - 278
  • [46] Thermodynamic properties of non-azeotropic refrigerant heat pumps under full operating conditions with non-phase-change heat sinks and heat soucres
    Hu, Hemin
    Wang, Tao
    Chen, Hao
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2025, 22 (04) : 774 - 791
  • [47] Development of natural refrigerant (CO2) heat pump water heater for residential use
    Taira, Teruhiko
    Nihon Enerugi Gakkaishi, 1600, 9 (649-654):
  • [48] Impact of an internal heat exchanger on a transcritical CO2 heat pump under optimal pressure conditions Optimal-pressure performance of CO2 heat pump with IHX
    Oton-Martinez, Ramon A.
    Illan-Gomez, Fernando
    Garcia-Cascales, Jose R.
    Velasco, F. J. S.
    Haddouche, M. Reda
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [49] Optimal combination of capillary tube geometry and refrigerant charge on a small CO2 water-source heat pump water heater
    Wang, Dong
    Lu, Yuehong
    Tao, Leren
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 88 : 626 - 636
  • [50] Effects on performance of small water-source heat pump water heater with CO2 by refrigerant charge and determination of optimal value
    Wang D.
    Liu Y.
    Chen Z.
    Kou Z.
    Lu Y.
    Huagong Xuebao/CIESC Journal, 2020, 71 : 397 - 403