A novel control method for the automotive CO2 heat pumps under inappropriate refrigerant charge conditions

被引:7
|
作者
Jia, Fan [1 ]
Yin, Xiang [2 ]
Cao, Feng [1 ,2 ]
Fang, Jianmin [2 ]
Wang, Anci [2 ]
Wang, Xixi [3 ]
Yang, Lichen [3 ]
机构
[1] Xi An Jiao Tong Univ, Natl Innovat Platform Ctr Ind Educ Integrat Energy, 28 Xianning West Rd, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Peoples R China
[3] Yutong Bus Co Ltd, Zhengzhou 450061, Peoples R China
基金
中国国家自然科学基金;
关键词
CO 2 heat pumps; Refrigerant charge; Charge control; System simulation; PERFORMANCE; SYSTEM; MODEL; FLOW;
D O I
10.1016/j.energy.2023.129533
中图分类号
O414.1 [热力学];
学科分类号
摘要
CO2 heat pumps are increasingly widely used in automotive air conditioning, and the demand for refrigerant charge varies greatly under different modes and operation conditions. However, due to the limited space in vehicles, the accumulator cannot fully meet the refrigerant balance requirements for the variable operating conditions, and states of inappropriate refrigerant charge were frequently observed. To enhance system performance and safety under inappropriate charge conditions, an experimental setup and a mathematical model with a maximum error of 6 % were established to investigate the operating characteristics under inappropriate charge conditions. An investigation into the interplay among discharge pressure, the appropriate refrigerant charge range, and refrigerant distribution was conducted. It elucidated how refrigerant charging states (undercharged, adequately charged, or overcharged) manifest in terms of refrigerant distribution and optimal discharge pressure. A novel control method based on refrigerant distribution regulation has been proposed. The proposed control logic could increase the system IPLV by 36.8 % when the refrigerant charge deviates from the appropriate range by 12.12 %, and the greater the dysregulation in the refrigerant charge, the greater the improvement. This control logic would be more enhanced if dysregulation was considered.
引用
收藏
页数:15
相关论文
共 50 条
  • [11] Control of Heat Pumps with CO2 Emission Intensity Forecasts
    Leerbeck, Kenneth
    Bacher, Peder
    Junker, Rune Gronborg
    Tveit, Anna
    Corradi, Olivier
    Madsen, Henrik
    Ebrahimy, Razgar
    ENERGIES, 2020, 13 (11)
  • [12] Solar irradiation and refrigerant charge effects on performance of direct expansion solar assisted heat pumps using CO2 transcritical cycle
    Humia, Gleberson M.
    Machado, Luiz
    Paulino, Tiago de Freitas
    Maia, Antonio A. T.
    Duarte, Willian M.
    APPLIED THERMAL ENGINEERING, 2025, 267
  • [13] Effects of refrigerant charge on performances of transcritical CO2 heat pump water heater
    Jin D.
    Koyama S.
    Xue J.
    Takata N.
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2010, 45 (05): : 680 - 684
  • [14] Consistent control strategy for CO2 refrigeration systems based on refrigerant charge management
    He, Yu-Jia
    Tai, Ying-Di
    Zhao, Xiao-Xuan
    Zhang, Chun-Lu
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 145 : 19 - 29
  • [15] A Novel Hybrid Deep Neural Network Model to Predict the Refrigerant Charge Amount of Heat Pumps
    Hwang, Jun Kwon
    Duhirwe, Patrick Nzivugira
    Yun, Geun Young
    Lee, Sukho
    Seo, Hyeongjoon
    Kim, Inhan
    Santamouris, Mat
    SUSTAINABILITY, 2020, 12 (07)
  • [16] Novel ground heat exchanger configurations for CO2 direct expansion geothermal heat pumps
    Eslami Nejad, Parham
    Badache, Messaoud
    Bastani, Arash
    Nguyen, Alain
    14TH IIR GUSTAV-LORENTZEN CONFERENCE ON NATURAL FLUIDS, 2020, : 417 - 422
  • [17] Approaching optimum COP by refrigerant charge management in transcritical CO2 heat pump water heater
    He, Yu-Jia
    Liang, Xing-Yu
    Cheng, Jia-Hao
    Shao, Liang-Liang
    Zhang, Chun-Lu
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 118 : 161 - 172
  • [18] An investigation of using CO2 heat pumps to charge PCM storage tank for domestic use
    Li, Yantong
    Nord, Natasa
    Yin, Huibin
    RENEWABLE ENERGY, 2023, 218
  • [19] CO2 heat pumps in controlled ventilation systems
    Rieberer, R
    Halozan, H
    NATURAL WORKING FLUIDS'98: IIR - GUSTAV LORENTZEN CONFERENCE, 1998, 1998 (04): : 212 - 222
  • [20] Effects of refrigerant charge amount on the optimal discharge pressure of a transcritical CO2 heat pump for electric vehicles
    Ji, Hongzeng
    Duan, Xiuhui
    Huang, Xiaoyu
    Ding, Chen
    Guo, Fen
    Wang, Yichun
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 59