A novel control method for the automotive CO2 heat pumps under inappropriate refrigerant charge conditions

被引:7
|
作者
Jia, Fan [1 ]
Yin, Xiang [2 ]
Cao, Feng [1 ,2 ]
Fang, Jianmin [2 ]
Wang, Anci [2 ]
Wang, Xixi [3 ]
Yang, Lichen [3 ]
机构
[1] Xi An Jiao Tong Univ, Natl Innovat Platform Ctr Ind Educ Integrat Energy, 28 Xianning West Rd, Xian 710049, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, 28 Xianning West Rd, Xian 710049, Peoples R China
[3] Yutong Bus Co Ltd, Zhengzhou 450061, Peoples R China
基金
中国国家自然科学基金;
关键词
CO 2 heat pumps; Refrigerant charge; Charge control; System simulation; PERFORMANCE; SYSTEM; MODEL; FLOW;
D O I
10.1016/j.energy.2023.129533
中图分类号
O414.1 [热力学];
学科分类号
摘要
CO2 heat pumps are increasingly widely used in automotive air conditioning, and the demand for refrigerant charge varies greatly under different modes and operation conditions. However, due to the limited space in vehicles, the accumulator cannot fully meet the refrigerant balance requirements for the variable operating conditions, and states of inappropriate refrigerant charge were frequently observed. To enhance system performance and safety under inappropriate charge conditions, an experimental setup and a mathematical model with a maximum error of 6 % were established to investigate the operating characteristics under inappropriate charge conditions. An investigation into the interplay among discharge pressure, the appropriate refrigerant charge range, and refrigerant distribution was conducted. It elucidated how refrigerant charging states (undercharged, adequately charged, or overcharged) manifest in terms of refrigerant distribution and optimal discharge pressure. A novel control method based on refrigerant distribution regulation has been proposed. The proposed control logic could increase the system IPLV by 36.8 % when the refrigerant charge deviates from the appropriate range by 12.12 %, and the greater the dysregulation in the refrigerant charge, the greater the improvement. This control logic would be more enhanced if dysregulation was considered.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Experimental investigation of refrigerant charge determination for heating performance in a CO2 heat pump system for electric vehicles
    Li, Gang
    Ma, Jianwei
    Zou, Huiming
    Zhang, Rongrong
    APPLIED THERMAL ENGINEERING, 2023, 233
  • [22] Influence of Refrigerant Charge Amount and EEV Opening on the Performance of a Transcritical CO2 Heat Pump Water Heater
    Zhang, Ze
    Dong, Xiaojun
    Ren, Zheng
    Lai, Tianwei
    Hou, Yu
    ENERGIES, 2017, 10 (10):
  • [23] Experimental performance evaluation of heat pump by using CO2 as a refrigerant
    Venkatesh, V. K.
    Basavaraju, M. G.
    Rao, K. V. Sreenivas
    INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS AND MANUFACTURING APPLICATIONS (ICONAMMA-2016), 2016, 149
  • [24] The residential heat pumps' impact on national CO2 emission
    Niemierka, Elzbieta
    10TH CONFERENCE ON INTERDISCIPLINARY PROBLEMS IN ENVIRONMENTAL PROTECTION AND ENGINEERING EKO-DOK 2018, 2018, 44
  • [25] Experimental study on refrigerant charge amount and optimal high pressure of a CO2 heat pump system for an electric bus
    Guo, Yang
    Yang, Wei
    Wu, Haimei
    Li, Tao
    Chen, Shangmai
    Jin, Zunlong
    Deng, Rongbin
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2022, 14 (06)
  • [26] Performance improvement of heat pumps by optimizing refrigerant charge using novel variable liquid-line length system
    Lee, DongChan
    Lee, Minwoo
    Cho, Wonhee
    Kim, Yongchan
    APPLIED THERMAL ENGINEERING, 2021, 196
  • [27] Research on the Adaptability of CO2 Ejector Under Automotive Conditions Ranging from -30 to 50 ℃
    Yang T.
    Zou H.
    Zhou H.
    Wang C.
    Tian C.
    Qiche Gongcheng/Automotive Engineering, 2024, 46 (04): : 682 - 690
  • [28] Performance Study of CO2 Heat Pump under Tropical Conditions of Singapore
    Soh, Alexander
    Dubey, Swapnil
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 1366 - 1371
  • [29] Charge transfer excitation in H2+ + CO2 collisions under beam conditions
    Pranszke, B.
    CHEMICAL PHYSICS LETTERS, 2010, 499 (4-6) : 199 - 202
  • [30] Heat exchangers in a CO2 automotive air conditioning system
    Liu, HS
    Chen, JP
    Chen, ZJ
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 795 - 800