V Flow Measurements of Pulsatile Flow in Femoral-Popliteal Bypass Proximal Anastomosis Compared with CFD Simulation

被引:1
|
作者
Yukhnev, Andrey [1 ]
Tikhomolova, Ludmila [1 ]
Gataulin, Yakov [1 ]
Marinova, Alexandra [1 ]
Smirnov, Evgueni [1 ]
Vrabiy, Andrey [2 ]
Suprunovich, Andrey [2 ]
Khubulava, Gennady [2 ]
机构
[1] Peter Great St Petersburg Polytech Univ, Higher Sch Appl Math & Computat Phys, 29 Polytechnicheskaya Str, St Petersburg 195251, Russia
[2] Pavlov First St Petersburg State Med Univ, Dept Fac Surg, 6-8 Lva Tolstogo Str, St Petersburg 197022, Russia
基金
俄罗斯科学基金会;
关键词
pulsatile blood flow; 3D numerical simulation; 2D ultrasound vector imaging; femoral popliteal bypass surgery; proximal anastomosis; personalized model; WALL SHEAR-STRESS; BLOOD-FLOW; VESSEL;
D O I
10.3390/fluids9030064
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This paper presents the experience of using the V Flow high-frame-rate ultrasound vector imaging method to study the pulsatile velocity fields in the area of the proximal anastomosis for femoral popliteal bypass surgery in vitro and in vivo. A representative (average) anastomosis model and the experimental setup designed for in vitro studies covering forward and reverse flow phases throughout the cycle are described. The results of the measurements are presented for areas with a relatively uniform velocity distribution and for areas with pronounced spatial inhomogeneities due to the jet or recirculating nature of the flow. The results of ultrasonic studies of the velocity field of the three-dimensional pulsatile flow in vitro and in vivo are compared with the data of numerical simulations carried out for the average and personalized models based on the Navier-Stokes equations. Acceptable consistency between the results of experimental and numerical studies is demonstrated.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] In-vivo measurements of blood flow velocity profiles in canine ilio-femoral anastomotic bypass grafts
    Jones, SA
    Giddens, DP
    Loth, F
    Zarins, CK
    Kajiya, F
    Morita, I
    Hiramatsu, O
    Ogasawara, Y
    Tsujioka, K
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (01): : 30 - 38
  • [32] Design of ring and spider type spargers for bubble column reactor: Experimental measurements and CFD simulation of flow and weeping
    Kulkarni, Anand V.
    Badgandi, Shrikant V.
    Joshi, Jyeshtharaj B.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2009, 87 (12A): : 1612 - 1630
  • [33] PIV measurements and CFD simulation of the performance and flow physics and of a small-scale vertical axis wind turbine
    Edwards, Jonathan M.
    Danao, Louis Angelo
    Howell, Robert J.
    WIND ENERGY, 2015, 18 (02) : 201 - 217
  • [34] In situ oil flow measurements in fired engine compared to one-dimensional lube circuit simulation
    Le Negrate, A.
    El Fassi, M.
    Cavallaro, G.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2011, 225 (J8) : 762 - 771
  • [35] CFD Simulation of Gas-solid flow in Dense Phase Bypass Pneumatic Conveying using the Euler-Euler Model
    Wang, Y.
    Williams, K. C.
    Jones, M. G.
    Chen, B.
    ADVANCED MECHANICAL ENGINEERING, PTS 1 AND 2, 2010, 26-28 : 1190 - 1194
  • [36] Influence of air flow rate on emission of DEHP from vinyl flooring in the emission cell FLEC: Measurements and CFD simulation
    Clausen, Per Axel
    Liu, Zhe
    Xu, Ying
    Kofoed-Sorensen, Vivi
    Little, John C.
    ATMOSPHERIC ENVIRONMENT, 2010, 44 (23) : 2760 - 2766
  • [37] Selection of the Relevant Turbulence Model in a CFD Simulation of a Flow Disturbed by Hydraulic Elbow — Comparative Analysis of the Simulation with Measurements Results Obtained by the Ultrasonic Flowmeter
    Piotr Piechota
    Piotr Synowiec
    Artur Andruszkiewicz
    Wiesław Wędrychowicz
    Journal of Thermal Science, 2018, 27 : 413 - 420
  • [38] Selection of the Relevant Turbulence Model in a CFD Simulation of a Flow Disturbed by Hydraulic Elbow——Comparative Analysis of the Simulation with Measurements Results Obtained by the Ultrasonic Flowmeter
    PIECHOTA Piotr
    SYNOWIEC Piotr
    ANDRUSZKIEWICZ Artur
    W?DRYCHOWICZ Wies?aw
    Journal of Thermal Science, 2018, 27 (05) : 413 - 420
  • [39] Selection of the Relevant Turbulence Model in a CFD Simulation of a Flow Disturbed by Hydraulic Elbow Comparative Analysis of the Simulation with Measurements Results Obtained by the Ultrasonic Flowmeter
    Piechota, Piotr
    Synowiec, Piotr
    Andruszkiewicz, Artur
    Wedrychowicz, Wieslaw
    JOURNAL OF THERMAL SCIENCE, 2018, 27 (05) : 413 - 420
  • [40] The influence of vessel wall elasticity and peripheral resistance on the carotid artery flow wave form: A CFD model compared to in vivo ultrasound measurements
    Maurits, N. M.
    Loots, G. E.
    Veldman, A. E. P.
    JOURNAL OF BIOMECHANICS, 2007, 40 (02) : 427 - 436