V Flow Measurements of Pulsatile Flow in Femoral-Popliteal Bypass Proximal Anastomosis Compared with CFD Simulation

被引:1
|
作者
Yukhnev, Andrey [1 ]
Tikhomolova, Ludmila [1 ]
Gataulin, Yakov [1 ]
Marinova, Alexandra [1 ]
Smirnov, Evgueni [1 ]
Vrabiy, Andrey [2 ]
Suprunovich, Andrey [2 ]
Khubulava, Gennady [2 ]
机构
[1] Peter Great St Petersburg Polytech Univ, Higher Sch Appl Math & Computat Phys, 29 Polytechnicheskaya Str, St Petersburg 195251, Russia
[2] Pavlov First St Petersburg State Med Univ, Dept Fac Surg, 6-8 Lva Tolstogo Str, St Petersburg 197022, Russia
基金
俄罗斯科学基金会;
关键词
pulsatile blood flow; 3D numerical simulation; 2D ultrasound vector imaging; femoral popliteal bypass surgery; proximal anastomosis; personalized model; WALL SHEAR-STRESS; BLOOD-FLOW; VESSEL;
D O I
10.3390/fluids9030064
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This paper presents the experience of using the V Flow high-frame-rate ultrasound vector imaging method to study the pulsatile velocity fields in the area of the proximal anastomosis for femoral popliteal bypass surgery in vitro and in vivo. A representative (average) anastomosis model and the experimental setup designed for in vitro studies covering forward and reverse flow phases throughout the cycle are described. The results of the measurements are presented for areas with a relatively uniform velocity distribution and for areas with pronounced spatial inhomogeneities due to the jet or recirculating nature of the flow. The results of ultrasonic studies of the velocity field of the three-dimensional pulsatile flow in vitro and in vivo are compared with the data of numerical simulations carried out for the average and personalized models based on the Navier-Stokes equations. Acceptable consistency between the results of experimental and numerical studies is demonstrated.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Pressure and flow distribution in pipe and ring spargers: Experimental measurements and CFD simulation
    Kulkarni, A.V.
    Roy, Swarnendu S.
    Joshi, J.B.
    Chemical Engineering Journal, 2007, 133 (1-3): : 173 - 186
  • [22] SIMULATION OF AORTO-CORONARY BYPASS ANASTOMOSES FLOW CONDITIONS USING DISTENSIBLE TUBING AND A PULSATILE PUMP
    KINLEY, CE
    MARBLE, AE
    SARWAL, SN
    WATTS, KC
    WATTON, J
    MASON, MA
    JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 526 - 526
  • [23] The effect of pulsatile blood flow during proximal graft in facilitation weaning from cardiopulmonary bypass pump in coronary artery bypass graft surgery
    Amouzegarzavareh, Seyed M.
    Lak, Marzieh
    CHIRURGIA-ITALY, 2020, 33 (04): : 193 - 196
  • [24] EFFECT OF V-A BYPASS PUMPING WITH PULSATILE ASSIST DEVICE ON HEMODYNAMICS AND MYOCARDIAL TISSUE BLOOD-FLOW
    ODAGIRI, S
    JOURNAL OF THE JAPANESE ASSOCIATION FOR THORACIC SURGERY, 1980, 28 (09): : 1421 - 1432
  • [25] Effect of Varying Anastomosis Angles for Non-Newtonian Pulsatile Blood Flow through Artery Bypass Graft Models: an LES Study
    Dey, Shamudra
    Ibtida, Tahsin
    Roy, Chandan Kumar
    Sakib, Nuruzzaman
    2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1494 - 1497
  • [26] Simulation of pulsatile blood flow through various cardiac defects and quantitative measurements of shunted blood volume
    Sonetha, Vaibhavi A.
    Bellare, Jayesh R.
    2ND INTERNATIONAL CONFERENCE ON NANOMATERIALS AND TECHNOLOGIES (CNT 2014), 2015, 10 : 706 - 713
  • [27] Critical aspects for a CFD simulation compared with PIV analysis of the flow field downstream of a prosthetic heart valve
    Grigioni, M
    Daniele, C
    Del Gaudio, C
    Balducci, A
    Morbiducci, U
    D'Avenio, G
    Barbaro, V
    SIMULATIONS IN BIOMEDICINE V, 2003, 7 : 271 - 280
  • [28] DISTRIBUTION OF OXYGENATED BLOOD IN ASCENDING AORTA AND CORONARY BLOOD-FLOW DURING RESPIRATORY SUPPORT WITH PARTIAL V-A BYPASS USING CONTINUOUS AND PULSATILE FLOW
    SZCZEPANSKI, KP
    ORNSHOLT, J
    EUROPEAN SURGICAL RESEARCH, 1976, 8 : 117 - 118
  • [29] CFD analysis of primary and secondary flows and PIV measurements in whirlpool and whirlpool kettle with pulsatile filling: Analysis of the flow in a swirl separator
    Jakubowski, Marek
    Stachnik, Marta
    Sterczynska, Monika
    Matysko, Robert
    Piepiorka-Stepuk, Joanna
    Dowgiallo, Andrzej
    Ageev, Oleg, V
    Knitter, Remigiusz
    JOURNAL OF FOOD ENGINEERING, 2019, 258 : 27 - 33
  • [30] Comparative Results of Air Flow Characters Mapped by CFD Simulation and Actual Measurements of Three Dimensional Air Flow Vectors and Particle Concentrations
    Katayama, Hirohito
    Katoh, Shigeo
    KAGAKU KOGAKU RONBUNSHU, 2008, 34 (04) : 452 - 457