V Flow Measurements of Pulsatile Flow in Femoral-Popliteal Bypass Proximal Anastomosis Compared with CFD Simulation

被引:1
|
作者
Yukhnev, Andrey [1 ]
Tikhomolova, Ludmila [1 ]
Gataulin, Yakov [1 ]
Marinova, Alexandra [1 ]
Smirnov, Evgueni [1 ]
Vrabiy, Andrey [2 ]
Suprunovich, Andrey [2 ]
Khubulava, Gennady [2 ]
机构
[1] Peter Great St Petersburg Polytech Univ, Higher Sch Appl Math & Computat Phys, 29 Polytechnicheskaya Str, St Petersburg 195251, Russia
[2] Pavlov First St Petersburg State Med Univ, Dept Fac Surg, 6-8 Lva Tolstogo Str, St Petersburg 197022, Russia
基金
俄罗斯科学基金会;
关键词
pulsatile blood flow; 3D numerical simulation; 2D ultrasound vector imaging; femoral popliteal bypass surgery; proximal anastomosis; personalized model; WALL SHEAR-STRESS; BLOOD-FLOW; VESSEL;
D O I
10.3390/fluids9030064
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
This paper presents the experience of using the V Flow high-frame-rate ultrasound vector imaging method to study the pulsatile velocity fields in the area of the proximal anastomosis for femoral popliteal bypass surgery in vitro and in vivo. A representative (average) anastomosis model and the experimental setup designed for in vitro studies covering forward and reverse flow phases throughout the cycle are described. The results of the measurements are presented for areas with a relatively uniform velocity distribution and for areas with pronounced spatial inhomogeneities due to the jet or recirculating nature of the flow. The results of ultrasonic studies of the velocity field of the three-dimensional pulsatile flow in vitro and in vivo are compared with the data of numerical simulations carried out for the average and personalized models based on the Navier-Stokes equations. Acceptable consistency between the results of experimental and numerical studies is demonstrated.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Experience of Patient-Specific CFD Simulation of Blood Flow in Proximal Anastomosis for Femoral-Popliteal Bypass
    Ivanova, Yana
    Yukhnev, Andrey
    Tikhomolova, Ludmila
    Smirnov, Evgueni
    Vrabiy, Andrey
    Suprunovich, Andrey
    Morozov, Alexey
    Khubulava, Gennady
    Vavilov, Valery
    FLUIDS, 2022, 7 (10)
  • [2] OPERATIVE BLOOD FLOW IN FEMORAL-POPLITEAL AND FEMORAL-TIBIAL GRAFTS FOR LOWER EXTREMITY ISCHEMIA
    BERNHARD, VM
    ASHMORE, CS
    RODGERS, RE
    EVANS, WE
    ARCHIVES OF SURGERY, 1971, 103 (05) : 595 - &
  • [3] Particle image velocimetry measurements of three proximal anastomosis models under a pulsatile flow condition
    Chua, L. P.
    Ji, W-F
    Yu, C. M.
    Zhou, T-M
    Tan, Y. S.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H3) : 249 - 263
  • [4] COMPARISON OF OPERATIVE BLOOD-FLOW IN FEMORAL-POPLITEAL AND FEMORAL-TIBIAL GRAFTS FOR LOWER-EXTREMITY ISCHEMIA
    BERNHARD, VM
    ASHMORE, C
    EVANS, WE
    RODGERS, RE
    JOURNAL OF CARDIOVASCULAR SURGERY, 1972, 13 (01): : 119 - &
  • [5] Measurements and CFD simulation of the flow in evaporating crystallizers
    Echeverri, L. F.
    Rein, P. W.
    Acharya, S.
    ZUCKERINDUSTRIE, 2007, 132 (11): : 817 - 823
  • [6] Simulation of Flow Field for Pulsatile Blood Flow in a Femoral Artery Based on Cosserat Continua
    Khani, Sina
    Atefi, Gholamali
    Soleimani, Afsaneh
    JOURNAL OF DISPERSION SCIENCE AND TECHNOLOGY, 2011, 32 (10) : 1371 - 1376
  • [7] CINEDENSITOMETRIC FLOW MEASUREMENTS IN THE FEMORAL POPLITEAL VESSELS BEFORE AND AFTER ANGIOPLASTY
    KRINGS, W
    ROTH, FJ
    DECKER, D
    IRION, KM
    RADIOLOGE, 1982, 22 (11): : 508 - 511
  • [8] Hemodynamic analysis of pulsatile blood flow in a complete bypass graft with different anastomosis angles
    Zohravi, E.
    Shirani, E.
    Sadeghi, M. R.
    SCIENTIA IRANICA, 2015, 22 (02) : 423 - 435
  • [9] Preservation of Endothelium Nitric Oxide Release by Pulsatile Flow Cardiopulmonary Bypass When Compared With Continuous Flow
    Lanzarone, Ettore
    Gelmini, Fabrizio
    Tessari, Maddalena
    Menon, Tiziano
    Suzuki, Hisanori
    Carini, Marina
    Costantino, Maria Laura
    Fumero, Roberto
    Luciani, Giovanni Battista
    Faggian, Giuseppe
    ARTIFICIAL ORGANS, 2009, 33 (11) : 926 - 934
  • [10] Simulation of Pulsatile flow of blood in stenosed coronary artery bypass with graft
    Wiwatanapataphee, B
    Poltem, D
    Wu, YH
    Lenbury, Y
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2006, 3 (02) : 371 - 383