A Single-Center Audit of BI-RADS 3 Assessment Category Utilization in Mammography and Breast Ultrasound

被引:0
|
作者
Common, Jessica [1 ]
Abdullah, Peri [2 ]
Alabousi, Abdullah [1 ,3 ,4 ]
机构
[1] McMaster Univ, Fac Hlth Sci, Dept Radiol, Hamilton, ON, Canada
[2] York Univ, Fac Hlth, Dept Kinesiol & Hlth Sci, Toronto, ON, Canada
[3] St Josephs Healthcare Hamilton, Dept Radiol, Hamilton, ON, Canada
[4] St Josephs Healthcare Hamilton, FRCPC, Dept Radiol, 50 Charlton Ave E, Hamilton, ON L8N 4A6, Canada
关键词
BI-RADS; 3; probably benign; mammography; breast ultrasound; cancer yield; PROBABLY BENIGN LESIONS; FOLLOW-UP; PATIENT COMPLIANCE; SURVEILLANCE;
D O I
10.1177/08465371221121706
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate outcomes of breast lesions assessed at our institution as probably benign (Breast Imaging Reporting and Data System [BI-RADS] category 3) with an expected malignancy rate of less than or equal to 2 %. Methods: Average-risk women with a BI-RADS 3 assessment following mammographic and/or ultrasound evaluation at our institution between January 1 and December 31, 2017 were included. Cancer yield was calculated within 90 days and at 6-month intervals up to 36 months. Results: Among 517 women (median age, 52 years; range, 13-89 years) with a BI-RADS 3 assessment, 349 (67.5 %) underwent biopsy or completed follow-up imaging up to 36 months. One hundred and 68 (32.5 %) were lost to follow-up. Thirty of 349 (8.6 %) had their imaging upgraded and underwent biopsy, yielding six cancers (cancer yield, 6 of 349 women [1.7 %]). Among 569 lesions assessed as BI-RADS 3, 92 (16.2 %) were characterized by morphologic features other than those validated as probably benign in prospective clinical studies. Fifty three of 517 women (10.3 %) had follow-up beyond 24 months, and 24 (4.6 %) had follow-up beyond 36 months. Conclusion: Overall utilization of the BI-RADS 3 assessment category at our institution is appropriate with a 1.7 % cancer yield. However, the rate of loss to follow-up, percentage of non-validated findings assessed as probably benign, and redundancy in follow-up protocols are too high, and warrant intervention. A patient handout explaining the BI-RADS 3 assessment category and automatic scheduling of follow-up studies have been implemented at our center to address loss to follow-up.
引用
收藏
页码:69 / 77
页数:9
相关论文
共 50 条
  • [31] Reassessment and Follow-Up Results of BI-RADS Category 3 Lesions Detected on Screening Breast Ultrasound
    Chae, Eun Young
    Cha, Joo Hee
    Shin, Hee Jung
    Choi, Woo Jung
    Kim, Hak Hee
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 206 (03) : 666 - 672
  • [32] Comparison of variability in breast density assessment by BI-RADS category according to the level of experience
    Eom, Hye-Joung
    Cha, Joo Hee
    Kang, Ji-Won
    Choi, Woo Jung
    Kim, Han Jun
    Go, EunChae
    ACTA RADIOLOGICA, 2018, 59 (05) : 527 - 532
  • [33] Is the breast ADC category system a useful addition to BI-RADS?
    Maya Honda
    Mami Iima
    European Radiology, 2023, 33 : 5398 - 5399
  • [34] Is the breast ADC category system a useful addition to BI-RADS?
    Honda, Maya
    Iima, Mami
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5398 - 5399
  • [35] Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions
    Liu, Hongbiao
    Than, Hongwei
    Sun, Da
    BMC CANCER, 2020, 20 (01)
  • [36] Disparities Associated With Patient Adherence to BI-RADS 3 Assessment Follow-up Recommendations for Mammography and Ultrasound
    Nguyen, Derek L.
    Wilson, Benjamin M.
    Oluyemi, Eniola
    Myers, Kelly S.
    Mullen, Lisa A.
    Panigrahi, Babita
    Ambinder, Emily B.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2022, 19 (12) : 1302 - 1309
  • [37] Comparison of 99mTc-MIBI scintigraphy, ultrasound, and mammography for the diagnosis of BI-RADS 4 category lesions
    Hongbiao Liu
    Hongwei Zhan
    Da Sun
    BMC Cancer, 20
  • [38] Beyond BI-RADS: Nonmass Abnormalities on Breast Ultrasound
    Tsunoda, Hiroko
    Moon, Woo Kyung
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (02) : 134 - 145
  • [39] Breast imaging reporting and data system (BI-RADS) lexicon for breast MRI: Interobserver variability in the description and assignment of BI-RADS category
    El Khoury, Mona
    Lalonde, Lucie
    David, Julie
    Labelle, Maude
    Mesurolle, Benoit
    Trop, Isabelle
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (01) : 71 - 76
  • [40] Diagnostic value of breast ultrasound in mammography BI-RADS 0 and clinically indeterminate or suspicious of malignancy breast lesions
    Dobrosavljevic, Aleksandar
    Rakic, Snezana
    Nikolic, Branka
    Raznatovic, Svetlana Jankovic
    Dikic, Svetlana Dragojevic
    Milosevic, Zorica
    Jurisic, Aleksandar
    Skrobic, Milica