摘要
BackgroundScatter radiation is a traditional problem in cone-beam computed tomography (CBCT). Accordingly, numerous methods have been researched for scatter reduction in terms of software- or hardware-based solutions. The concept of a two-dimensional antiscatter grid (2D-ASG) has been shown to provide a solution to the scatter reduction in CBCT. However, the use of an ASG makes it challenging to use in clinical CBCT systems because it causes Moire artifacts of the image. PurposeWe have developed a Moire-free 2D-ASG that was designed to solve the Moire artifact and the scatter radiation problems. We provide the experimental results pertaining to the image quality measurements from the evaluation of the 2D-ASG compared with those obtained from a one-dimensional antiscatter grid (1D-ASG) and no antiscatter grid (No-ASG) to demonstrate the quantitative extent of the improvements. MethodsThe 2D-ASG, fabricated based on a sawing process with a graphite body, was prepared to evaluate image quality improvements. Projection images for Pro-CT MK II phantom were acquired using the CBCT testbed of sample rotation type and reconstructed by Feldkamp-Davis-Kress (FDK) algorithm without any filters. We measured the contrast-to-noise ratio (CNR) and uniformity index for the cupping artifacts of the 2D-ASG, 1D-ASG, and No-ASG cases. Results2D-ASG considerably reduced the cupping artifacts owing to the scatter reduction compared with the 1D-ASG and No-ASG cases. The cupping artifacts were reduced by 85% in the 2D-ASG compared with No-ASG, while the cupping artifacts were reduced by 63% in 1D-ASG compared with No-ASG. The 2D-ASG also yielded a CNR improvement. The average CNR improvements for eight insert materials were 47% in the 2D-ASG compared with No-ASG, while the CNR was improved by 36% in the 1D-ASG compared with No-ASG. ConclusionsWe demonstrated that the Moire-free 2D-ASG improved the image quality by removing scatter radiation in CBCT compared with 1D-ASG and No-ASG. We believe that the Moire-free 2D-ASG can become one of the effective ways to solve the scatter radiation problem in CBCT images because it provides usability and has the potential to have synergistic effects on other methods, such as bow-tie filter and scatter correction.
引用
收藏
页码:3435 / 3444
页数:10
相关论文
共 50 条
  • [1] Two-dimensional antiscatter grid: A novel scatter rejection device for Cone-beam computed tomography
    Alexeev, Timur
    Kavanagh, Brian
    Miften, Moyed
    Altunbas, Cem
    MEDICAL PHYSICS, 2018, 45 (02) : 529 - 534
  • [2] Comparative Evaluation of the Artefacts Index of Dental Materials on Two-Dimensional Cone-beam Computed Tomography
    Fusong Yuan
    Litong Chen
    Xiaofei Wang
    Yong Wang
    Peijun Lyu
    Yuchun Sun
    Scientific Reports, 6
  • [3] Comparative Evaluation of the Artefacts Index of Dental Materials on Two-Dimensional Cone-beam Computed Tomography
    Yuan, Fusong
    Chen, Litong
    Wang, Xiaofei
    Wang, Yong
    Lyu, Peijun
    Sun, Yuchun
    SCIENTIFIC REPORTS, 2016, 6
  • [4] Removing grid artifacts from a two-dimensional crisscrossed grid in cone-beam computed tomography to enhance image quality
    Jeon, Duhee
    Kim, Woosung
    Cho, Hyosung
    Park, Myeongkyu
    JOURNAL OF INSTRUMENTATION, 2024, 19 (03)
  • [5] Effect of a prototype 2-dimensional antiscatter grid on image quality obtained with a dental cone-beam computed tomography scanner
    Li, Boyuan
    Somerkivi, Villeseveri
    Bayat, Farhang
    Huynh, Carolyn
    Altunbas, Cem
    IMAGING SCIENCE IN DENTISTRY, 2025,
  • [6] Monte Carlo Study On a Cone-Beam Computed Tomography Using a Cross-Type Carbon Fiber Antiscatter Grid
    Usui, K.
    Inoue, T.
    Kurokawa, C.
    Sugimoto, S.
    Sasai, K.
    Ogawa, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3422 - 3422
  • [7] The Three-Dimensional Evaluation of Radicular Cyst by Cone-Beam Computed Tomography
    Viggness, Arun
    Priyaa, Sasti
    Thangavelu, Ravikumar Pethagounder
    Fenn, Saramma Mathew
    Mohan, Karthik Rajaram
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [8] Three-Dimensional Evaluation of Bifid Condyle by Cone-Beam Computed Tomography
    Sargurunathan, Ezhilarasi Arumugam Venkatachalam
    Rajkumar, Ignatious Jeba Mary
    Reddy, Ramachandra Venkatesha
    Fenn, Saramma Mathew
    Mohan, Karthik Rajaram
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (10)
  • [9] Cone-beam Computed Tomography Evaluation of Maxillary Sinusitis
    Maillet, Michelle
    Bowles, Walter R.
    McClanahan, Scott L.
    John, Mike T.
    Ahmad, Mansur
    JOURNAL OF ENDODONTICS, 2011, 37 (06) : 753 - 757
  • [10] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Erdem, Sule
    Zengin, Ayse Zeynep
    Erdem, Suheda
    SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (11) : 1307 - 1313