Comparative Evaluation of the Artefacts Index of Dental Materials on Two-Dimensional Cone-beam Computed Tomography

被引:0
|
作者
Fusong Yuan
Litong Chen
Xiaofei Wang
Yong Wang
Peijun Lyu
Yuchun Sun
机构
[1] Centre of Digital Dentistry,
[2] Peking University School and Hospital of Stomatology & National Engineering Laboratory for Digital and Material Technology of Stomatology & Research Centre of Engineering and Technology for Digital Dentistry of Ministry of Health,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The aim of the study was to propose the artefact index on cone-beam computed tomography (CBCT) images of clinical prosthodontics materials and to compare the effect of the artefacts on CBCT image clarity of normal oral tissues. Seven spheres of different materials were secured on the centre of a resin baseboard, respectively and four human molars in vitro were placed at 10 mm front, back, left and right of the sphere. The board was scanned using CBCT with the same setting. 10 tomographic images from each of the seven data sets with clear artefacts was selected. The grayscale measuring tool of Photoshop software was used to measure the grayscale (G0) within the boundary of tomographic image and the grayscales of the streaky artefacts that were 1 mm and 20 mm outside the circular boundary (G1 and G2). The arc length, L1, of the circular boundary with artefacts was measured; the circumference, L2, was calculated. The artefact index, A, was determined as (G1/G0) × 0.5 + (G2/G1) × 0.4 + (L2/L1) × 0.1. The artefact index A can comprehensively represent the effect of artefacts on CBCT image clarity for oral tissue.
引用
收藏
相关论文
共 50 条
  • [1] Comparative Evaluation of the Artefacts Index of Dental Materials on Two-Dimensional Cone-beam Computed Tomography
    Yuan, Fusong
    Chen, Litong
    Wang, Xiaofei
    Wang, Yong
    Lyu, Peijun
    Sun, Yuchun
    SCIENTIFIC REPORTS, 2016, 6
  • [2] Evaluation of a two-dimensional Moire-free antiscatter grid for cone-beam computed tomography
    Kim, Jongkuk
    Kang, Yoonseok
    Hwang, Taesoon
    Park, Myungkyu
    Chung, Woohyun
    MEDICAL PHYSICS, 2023, 50 (06) : 3435 - 3444
  • [3] Evaluation of Dental Root Fracture Using Cone-beam Computed Tomography
    Wang, Pei
    Yan, Xue Bing
    Liu, Deng Gao
    Zhang, Wan Lin
    Zhang, Zu Yan
    Ma, Xu Chen
    CHINESE JOURNAL OF DENTAL RESEARCH, 2010, 13 (01): : 31 - 35
  • [4] Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials
    Polyane Mazucatto Queiroz
    Matheus Lima Oliveira
    Francisco Carlos Groppo
    Francisco Haiter-Neto
    Deborah Queiroz Freitas
    Clinical Oral Investigations, 2018, 22 : 419 - 423
  • [5] Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials
    Queiroz, Polyane Mazucatto
    Oliveira, Matheus Lima
    Groppo, Francisco Carlos
    Haiter-Neto, Francisco
    Freitas, Deborah Queiroz
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (01) : 419 - 423
  • [6] Clinical guidelines for dental cone-beam computed tomography
    Takafumi Hayashi
    Yoshinori Arai
    Toru Chikui
    Sachiko Hayashi-Sakai
    Kazuya Honda
    Hiroko Indo
    Taisuke Kawai
    Kaoru Kobayashi
    Shumei Murakami
    Masako Nagasawa
    Munetaka Naitoh
    Eiji Nakayama
    Yutaka Nikkuni
    Hideyoshi Nishiyama
    Noriaki Shoji
    Shigeaki Suenaga
    Ray Tanaka
    Oral Radiology, 2018, 34 : 89 - 104
  • [7] Quality Control in Dental Cone-Beam Computed Tomography
    Huang, Jin-Feng
    Chen, Xiao-Zhao
    Wang, Hong
    APPLIED SCIENCES-BASEL, 2021, 11 (17):
  • [8] Clinical guidelines for dental cone-beam computed tomography
    Hayashi, Takafumi
    Arai, Yoshinori
    Chikui, Toru
    Hayashi-Sakai, Sachiko
    Honda, Kazuya
    Indo, Hiroko
    Kawai, Taisuke
    Kobayashi, Kaoru
    Murakami, Shumei
    Nagasawa, Masako
    Naitoh, Munetaka
    Nakayama, Eiji
    Nikkuni, Yutaka
    Nishiyama, Hideyoshi
    Shoji, Noriaki
    Suenaga, Shigeaki
    Tanaka, Ray
    ORAL RADIOLOGY, 2018, 34 (02) : 89 - 104
  • [9] Two-dimensional antiscatter grid: A novel scatter rejection device for Cone-beam computed tomography
    Alexeev, Timur
    Kavanagh, Brian
    Miften, Moyed
    Altunbas, Cem
    MEDICAL PHYSICS, 2018, 45 (02) : 529 - 534
  • [10] DOSIMETRIC EVALUATION OF DENTAL IMPLANT PLANNING EXAMINATIONS WITH CONE-BEAM COMPUTED TOMOGRAPHY
    Andrade, Marcos E. A.
    Khoury, Helen J.
    Nascimento Neto, Joao B. S.
    Kramer, Richard
    RADIATION PROTECTION DOSIMETRY, 2014, 158 (02) : 175 - 180