Evaluation of a two-dimensional Moire-free antiscatter grid for cone-beam computed tomography

被引:1
|
作者
Kim, Jongkuk [1 ]
Kang, Yoonseok [1 ]
Hwang, Taesoon [1 ]
Park, Myungkyu [1 ]
Chung, Woohyun [1 ]
机构
[1] JPI Healthcare Co Ltd, Dept Grid Res & Dev, 43 Seonggok Ro 22beon Gil, Ansan 15424, Gyeonggi Do, South Korea
关键词
CBCT imaging; grids; scatter reduction; SCATTER CORRECTION METHODS; DIGITAL RADIOGRAPHY; GENERAL FRAMEWORK; IMAGE QUALITY; CT;
D O I
10.1002/mp.16243
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundScatter radiation is a traditional problem in cone-beam computed tomography (CBCT). Accordingly, numerous methods have been researched for scatter reduction in terms of software- or hardware-based solutions. The concept of a two-dimensional antiscatter grid (2D-ASG) has been shown to provide a solution to the scatter reduction in CBCT. However, the use of an ASG makes it challenging to use in clinical CBCT systems because it causes Moire artifacts of the image. PurposeWe have developed a Moire-free 2D-ASG that was designed to solve the Moire artifact and the scatter radiation problems. We provide the experimental results pertaining to the image quality measurements from the evaluation of the 2D-ASG compared with those obtained from a one-dimensional antiscatter grid (1D-ASG) and no antiscatter grid (No-ASG) to demonstrate the quantitative extent of the improvements. MethodsThe 2D-ASG, fabricated based on a sawing process with a graphite body, was prepared to evaluate image quality improvements. Projection images for Pro-CT MK II phantom were acquired using the CBCT testbed of sample rotation type and reconstructed by Feldkamp-Davis-Kress (FDK) algorithm without any filters. We measured the contrast-to-noise ratio (CNR) and uniformity index for the cupping artifacts of the 2D-ASG, 1D-ASG, and No-ASG cases. Results2D-ASG considerably reduced the cupping artifacts owing to the scatter reduction compared with the 1D-ASG and No-ASG cases. The cupping artifacts were reduced by 85% in the 2D-ASG compared with No-ASG, while the cupping artifacts were reduced by 63% in 1D-ASG compared with No-ASG. The 2D-ASG also yielded a CNR improvement. The average CNR improvements for eight insert materials were 47% in the 2D-ASG compared with No-ASG, while the CNR was improved by 36% in the 1D-ASG compared with No-ASG. ConclusionsWe demonstrated that the Moire-free 2D-ASG improved the image quality by removing scatter radiation in CBCT compared with 1D-ASG and No-ASG. We believe that the Moire-free 2D-ASG can become one of the effective ways to solve the scatter radiation problem in CBCT images because it provides usability and has the potential to have synergistic effects on other methods, such as bow-tie filter and scatter correction.
引用
收藏
页码:3435 / 3444
页数:10
相关论文
共 50 条
  • [21] EVALUATION OF DOSE HOMOGENEITY IN CONE-BEAM BREAST COMPUTED TOMOGRAPHY
    Mettivier, Giovanni
    Costa, Matilde
    Lanconelli, Nico
    Ianiro, Anna
    Pugliese, Mariagabriella
    Quarto, Maria
    Russo, Paolo
    RADIATION PROTECTION DOSIMETRY, 2017, 175 (04) : 473 - 481
  • [22] Evaluation of the nasopalatine canal and variations with cone-beam computed tomography
    Meryem Etoz
    Yıldıray Sisman
    Surgical and Radiologic Anatomy, 2014, 36 : 805 - 812
  • [23] Evaluation of mastoid pneumatization using cone-beam computed tomography
    Demirel, Oguzhan
    Kaya, Elif
    Ucok, Cemile Ozlem
    ORAL RADIOLOGY, 2014, 30 (01) : 92 - 97
  • [24] Evaluation of Mandibular Lingual Foramina With Cone-Beam Computed Tomography
    Zhang, Chunan
    Zhuang, Longfei
    Fan, Linfeng
    Mo, Jiaji
    Huang, Zhuoli
    Gu, Yingxin
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (04) : E389 - E394
  • [25] Morphometric evaluation of the temporomandibular joint on cone-beam computed tomography
    Ayyildiz, Elif
    Orhan, Mustafa
    Bahsi, Ilhan
    Yalcin, Eda Didem
    SURGICAL AND RADIOLOGIC ANATOMY, 2021, 43 (06) : 975 - 996
  • [26] Evaluation of the nasopalatine canal and variations with cone-beam computed tomography
    Etoz, Meryem
    Sisman, Yildiray
    SURGICAL AND RADIOLOGIC ANATOMY, 2014, 36 (08) : 805 - 812
  • [27] Comparison of cone-beam computed tomography cephalometric measurements using a midsagittal projection and conventional two-dimensional cephalometric measurements
    Jung, Pil-Kyo
    Lee, Gung-Chol
    Moon, Cheol-Hyun
    KOREAN JOURNAL OF ORTHODONTICS, 2015, 45 (06) : 282 - 288
  • [28] 3-Dimensional cone-beam computed tomography superimposition: A review
    Park, Jae Hyun
    Tai, Kiyoshi
    Owtad, Payam
    SEMINARS IN ORTHODONTICS, 2015, 21 (04) : 263 - 273
  • [29] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [30] Three-dimensional analysis of the airway with cone-beam computed tomography
    Stratemann, Scott
    Huang, John C.
    Maki, Koutaro
    Hatcher, David
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (05) : 607 - 615