Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems

被引:1
|
作者
Fusch, Gerhard [1 ]
Mohamed, Saber [2 ]
Bakry, Ahmad [1 ]
Li, Edward W. [1 ]
Dutta, Sourabh [1 ,3 ]
Helou, Salhab el [1 ]
Fusch, Christoph [1 ,4 ]
机构
[1] McMaster Univ, Dept Pediat, Div Neonatol, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Mech Engn, Hamilton, ON, Canada
[3] Postgrad Inst Med Educ & Res PGIMER, Dept Pediat, Neonatal Unit, Chandigarh, India
[4] Paracelsus Med Univ Nuremberg, Dept Pediat, Nurnberg, Germany
关键词
Sound pressure; Occupational noise; Environmental exposure; Disorders of environmental origin; SOUND LEVELS; WARD; ROOM;
D O I
10.1007/s00431-023-05335-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Reorganization of neonatal intensive care by introducing clinical microsystems may help to allocate nursing time more appropriately to the needs of patients. However, there is concern that cohorting infants according to acuity may enhance noise levels. This single-center study investigated the impact of reorganization of neonatal intensive care unit by implementing clinical microsystems in a Level III NICU on environmental noise. This prospective study measured 24-h noise levels over a period of 6 months during pre- and post-implementation of microsystems cohorting infants of similar acuity. Comparative analyses of the mixed acuity (i.e., before) and the cohorting (i.e., after) model were performed by creating daily profiles from continuous noise level measurements and calculating the length of exposure to predefined noise levels. Compared to baseline daytime measurements, noise levels were 3-6 dBA higher during physician handover. Noise levels were 2-3 dBA lower on weekends and 3-4 dBA lower at night, independent of the organizational model. The introduction of clinical microsystems slightly increased average noise levels for high-acuity pods (A and B) but produced a much more substantial decrease for low-acuity pods (E), leading to an overall reduction in unit-wide noise levels. Conclusion: Our data show that noise levels are more driven by human behavior than by technical devices. Implementation of microsystems may help to reduce noise exposure in the lower acuity pods in a NICU.What is Known:center dot Excessive noise levels can lead to adverse effects on the health and development of premature infants and other critically ill newborns.center dot The reorganization of the neonatal intensive care unit following the clinical microsystems principles might improve quality of care but also affect noise exposure of staff and patients.What is New:center dot The transition from a mixed -acuity to cohorting model is associated with an overall reduction in noise levels, particularly in low-acuity pods requiring less nursing care.center dot Nevertheless, baseline noise levels in both models exceeded the standard permissible limits.
引用
收藏
页码:1245 / 1254
页数:10
相关论文
共 50 条
  • [41] Impact of respiratory viruses in the neonatal intensive care unit
    Jessica E. Shui
    Maria Messina
    Alexandra C. Hill-Ricciuti
    Philip Maykowski
    Tina Leone
    Rakesh Sahni
    Joseph R. Isler
    Lisa Saiman
    Journal of Perinatology, 2018, 38 : 1556 - 1565
  • [42] CLINICAL TOXICOLOGY IN THE NEONATAL INTENSIVE-CARE UNIT
    BANNER, W
    MEDICAL TOXICOLOGY AND ADVERSE DRUG EXPERIENCE, 1986, 1 (03): : 225 - 235
  • [43] Stress levels of newborns parents in Neonatal Intensive Care Unit
    Stube, Marileia
    Calegaro da Rosa, Marina Brites
    Pretto, Carolina Renz
    da Cruz, Cibele Thome
    Morin, Pamela Vione
    Fernandes Stumm, Eniva Miladi
    REV RENE, 2018, 19
  • [44] Maintaining reduced noise levels in a resource-constrained neonatal intensive care unit by operant conditioning
    A. Ramesh
    S. B. Denzil
    R. Linda
    P. K. Josephine
    M. Nagapoornima
    P. N. Suman Rao
    A. Swarna Rekha
    Indian Pediatrics, 2013, 50 : 279 - 282
  • [45] Maintaining reduced noise levels in a resource-constrained neonatal intensive care unit by operant conditioning
    Ramesh, A.
    Denzil, S. B.
    Linda, R.
    Josephine, P. K.
    Nagapoornima, M.
    Rao, P. N. Suman
    Rekha, A. Swarna
    INDIAN PEDIATRICS, 2013, 50 (03) : 279 - 282
  • [46] NOISE-LEVELS IN A NEONATOLOGICAL INTENSIVE-CARE UNIT
    TILLER, R
    KUNZEL, V
    DEUTSCHE GESUNDHEITSWESEN-ZEITSCHRIFT FUR KLINISCHE MEDIZIN, 1979, 34 (49): : 2478 - 2482
  • [47] Level and Noise Sources in the Neonatal Intensive Care Unit of a Reference Hospital
    Hernandez-Salazar, Alma Damaris
    Gallegos-Martinez, Josefina
    Reyes-Hernandez, Jaime
    INVESTIGACION Y EDUCACION EN ENFERMERIA, 2020, 38 (03):
  • [48] Characterization of acoustic noise in a neonatal intensive care unit MRI system
    Tkach, Jean A.
    Li, Yu
    Pratt, Ronald G.
    Baroch, Kelly A.
    Loew, Wolfgang
    Daniels, Barret R.
    Giaquinto, Randy O.
    Merhar, Stephanie L.
    Kline-Fath, Beth M.
    Dumoulin, Charles L.
    PEDIATRIC RADIOLOGY, 2014, 44 (08) : 1011 - 1019
  • [49] Noise sources and levels in the Evgenidion Hospital intensive care unit
    Tsiou, C
    Eftymiatos, D
    Theodossopoulou, E
    Notis, P
    Kiriakou, K
    INTENSIVE CARE MEDICINE, 1998, 24 (08) : 845 - 847
  • [50] Noise sources and levels in the evgenidion hospital intensive care unit
    C. Tsiou
    D. Eftymiatos
    E. Theodossopoulou
    P. Notis
    K. Kiriakou
    Intensive Care Medicine, 1998, 24 : 845 - 847