Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems

被引:1
|
作者
Fusch, Gerhard [1 ]
Mohamed, Saber [2 ]
Bakry, Ahmad [1 ]
Li, Edward W. [1 ]
Dutta, Sourabh [1 ,3 ]
Helou, Salhab el [1 ]
Fusch, Christoph [1 ,4 ]
机构
[1] McMaster Univ, Dept Pediat, Div Neonatol, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Mech Engn, Hamilton, ON, Canada
[3] Postgrad Inst Med Educ & Res PGIMER, Dept Pediat, Neonatal Unit, Chandigarh, India
[4] Paracelsus Med Univ Nuremberg, Dept Pediat, Nurnberg, Germany
关键词
Sound pressure; Occupational noise; Environmental exposure; Disorders of environmental origin; SOUND LEVELS; WARD; ROOM;
D O I
10.1007/s00431-023-05335-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Reorganization of neonatal intensive care by introducing clinical microsystems may help to allocate nursing time more appropriately to the needs of patients. However, there is concern that cohorting infants according to acuity may enhance noise levels. This single-center study investigated the impact of reorganization of neonatal intensive care unit by implementing clinical microsystems in a Level III NICU on environmental noise. This prospective study measured 24-h noise levels over a period of 6 months during pre- and post-implementation of microsystems cohorting infants of similar acuity. Comparative analyses of the mixed acuity (i.e., before) and the cohorting (i.e., after) model were performed by creating daily profiles from continuous noise level measurements and calculating the length of exposure to predefined noise levels. Compared to baseline daytime measurements, noise levels were 3-6 dBA higher during physician handover. Noise levels were 2-3 dBA lower on weekends and 3-4 dBA lower at night, independent of the organizational model. The introduction of clinical microsystems slightly increased average noise levels for high-acuity pods (A and B) but produced a much more substantial decrease for low-acuity pods (E), leading to an overall reduction in unit-wide noise levels. Conclusion: Our data show that noise levels are more driven by human behavior than by technical devices. Implementation of microsystems may help to reduce noise exposure in the lower acuity pods in a NICU.What is Known:center dot Excessive noise levels can lead to adverse effects on the health and development of premature infants and other critically ill newborns.center dot The reorganization of the neonatal intensive care unit following the clinical microsystems principles might improve quality of care but also affect noise exposure of staff and patients.What is New:center dot The transition from a mixed -acuity to cohorting model is associated with an overall reduction in noise levels, particularly in low-acuity pods requiring less nursing care.center dot Nevertheless, baseline noise levels in both models exceeded the standard permissible limits.
引用
收藏
页码:1245 / 1254
页数:10
相关论文
共 50 条
  • [31] Neonatal intensive care unit incubators reduce language and noise levels more than the womb
    Brian B. Monson
    Jenna Rock
    Molly Cull
    Vitaliy Soloveychik
    Journal of Perinatology, 2020, 40 : 600 - 606
  • [32] Neonatal intensive care unit incubators reduce language and noise levels more than the womb
    Monson, Brian B.
    Rock, Jenna
    Cull, Molly
    Soloveychik, Vitaliy
    JOURNAL OF PERINATOLOGY, 2020, 40 (04) : 600 - 606
  • [33] Analysis of Serum γ-Glutamyl Transferase Levels in Neonatal Intensive Care Unit Patients
    Hirfanoglu, Ibrahim M.
    Unal, Sezin
    Onal, E. Esra
    Beken, Serdar
    Turkyilmaz, Canan
    Pasaoglu, Hatice
    Koc, Esin
    Ergenekon, Ebru
    Atalay, Yildiz
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2014, 58 (01): : 99 - 101
  • [34] Noise levels in an academic veterinary intensive care unit
    Dornbusch, Josephine
    Boston, Sarah
    Colee, James
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2020, 30 (06) : 632 - 637
  • [35] Noise pollution levels in the pediatric intensive care unit
    Kramer, Bree
    Joshi, Prashant
    Heard, Christopher
    JOURNAL OF CRITICAL CARE, 2016, 36 : 111 - 115
  • [36] NOISE POLLUTION LEVELS IN THE PEDIATRIC INTENSIVE CARE UNIT
    Kramer, Bree
    Heard, Christopher
    CRITICAL CARE MEDICINE, 2010, 38 (12) : U176 - U176
  • [37] Noise exposure of the newborn in the incubator at the neonatal intensive care unit
    Bieber, C.
    Thoma, R.
    KLINISCHE PADIATRIE, 2007, 219 (02): : 105 - 105
  • [38] Peak noise distribution in the neonatal intensive care unit † 1113
    Alex F Robertson
    Celeste Cooper-Peel
    Paul Vos
    Pediatric Research, 1998, 43 (Suppl 4) : 191 - 191
  • [39] IMPACT OF NEONATAL INTENSIVE-CARE ON FAMILY UNIT
    MORGART, D
    COLE, A
    FRIEDMAN, Z
    MAISELS, MJ
    PEDIATRIC RESEARCH, 1976, 10 (04) : 306 - 306
  • [40] Impact of respiratory viruses in the neonatal intensive care unit
    Shui, Jessica E.
    Messina, Maria
    Hill-Ricciuti, Alexandra C.
    Maykowski, Philip
    Leone, Tina
    Sahni, Rakesh
    Isler, Joseph R.
    Saiman, Lisa
    JOURNAL OF PERINATOLOGY, 2018, 38 (11) : 1556 - 1565