Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems

被引:1
|
作者
Fusch, Gerhard [1 ]
Mohamed, Saber [2 ]
Bakry, Ahmad [1 ]
Li, Edward W. [1 ]
Dutta, Sourabh [1 ,3 ]
Helou, Salhab el [1 ]
Fusch, Christoph [1 ,4 ]
机构
[1] McMaster Univ, Dept Pediat, Div Neonatol, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Mech Engn, Hamilton, ON, Canada
[3] Postgrad Inst Med Educ & Res PGIMER, Dept Pediat, Neonatal Unit, Chandigarh, India
[4] Paracelsus Med Univ Nuremberg, Dept Pediat, Nurnberg, Germany
关键词
Sound pressure; Occupational noise; Environmental exposure; Disorders of environmental origin; SOUND LEVELS; WARD; ROOM;
D O I
10.1007/s00431-023-05335-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Reorganization of neonatal intensive care by introducing clinical microsystems may help to allocate nursing time more appropriately to the needs of patients. However, there is concern that cohorting infants according to acuity may enhance noise levels. This single-center study investigated the impact of reorganization of neonatal intensive care unit by implementing clinical microsystems in a Level III NICU on environmental noise. This prospective study measured 24-h noise levels over a period of 6 months during pre- and post-implementation of microsystems cohorting infants of similar acuity. Comparative analyses of the mixed acuity (i.e., before) and the cohorting (i.e., after) model were performed by creating daily profiles from continuous noise level measurements and calculating the length of exposure to predefined noise levels. Compared to baseline daytime measurements, noise levels were 3-6 dBA higher during physician handover. Noise levels were 2-3 dBA lower on weekends and 3-4 dBA lower at night, independent of the organizational model. The introduction of clinical microsystems slightly increased average noise levels for high-acuity pods (A and B) but produced a much more substantial decrease for low-acuity pods (E), leading to an overall reduction in unit-wide noise levels. Conclusion: Our data show that noise levels are more driven by human behavior than by technical devices. Implementation of microsystems may help to reduce noise exposure in the lower acuity pods in a NICU.What is Known:center dot Excessive noise levels can lead to adverse effects on the health and development of premature infants and other critically ill newborns.center dot The reorganization of the neonatal intensive care unit following the clinical microsystems principles might improve quality of care but also affect noise exposure of staff and patients.What is New:center dot The transition from a mixed -acuity to cohorting model is associated with an overall reduction in noise levels, particularly in low-acuity pods requiring less nursing care.center dot Nevertheless, baseline noise levels in both models exceeded the standard permissible limits.
引用
收藏
页码:1245 / 1254
页数:10
相关论文
共 50 条
  • [21] Efficacy of a low cost protocol in reducing noise levels in the neonatal intensive care unit
    A. Ramesh
    P. N. Suman Rao
    G. Sandeep
    M. Nagapoornima
    V. Srilakshmi
    M. Dominic
    The Indian Journal of Pediatrics, 2009, 76 : 475 - 478
  • [22] Noise at the Neonatal Intensive Care Unit and inside the incubator
    Pinheiro, Eliana Moreira
    Guinsburg, Ruth
    de Araujo Nabuco, Marco Antonio
    Kakehashi, Tereza Yoshiko
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2011, 19 (05): : 1214 - 1221
  • [23] A two-pronged approach to reduce noise levels in the neonatal intensive care unit
    Casey, Lara
    Fucile, Sandra
    Flavin, Michael
    Dow, Kimberly
    EARLY HUMAN DEVELOPMENT, 2020, 146
  • [24] Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette
    Altuncu, E.
    Akman, I.
    Kulekci, S.
    Akdas, F.
    Bilgen, H.
    Ozek, E.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2009, 73 (07) : 951 - 953
  • [25] The Impact of Structural Changes on Sound Pressure Levels in a Neonatal Intensive Care Unit
    Carvalhais, Carlos
    Rodrigues, Celia
    Xavier, Ana
    V. Silva, Manuela
    Santos, Joana
    ARCHIVES OF ACOUSTICS, 2021, 46 (03) : 435 - 442
  • [26] The impact of a noise reduction quality improvement project upon sound levels in the open-unit-design neonatal intensive care unit
    Liu, W. F.
    JOURNAL OF PERINATOLOGY, 2010, 30 (07) : 489 - 496
  • [27] The impact of a noise reduction quality improvement project upon sound levels in the open-unit-design neonatal intensive care unit
    W F Liu
    Journal of Perinatology, 2010, 30 : 489 - 496
  • [28] Sound pressure levels in the Neonatal Intensive Care Unit
    Peixoto, Priscila Vendramini
    Nabuco de Araujo, Marco Antonio
    Kakehashi, Tereza Yoshiko
    Pinheiro, Eliana Moreira
    REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2011, 45 (06) : 1308 - 1313
  • [29] ECONOMIC IMPACT OF CLINICAL PHARMACIST INTERVENTIONS IN THE NEONATAL INTENSIVE CARE UNIT IN QATAR
    Abushanab, D.
    Al-Badriyeh, D.
    Rijims, M.
    Rouf, Abdul P.
    Al Hail, M.
    Elkassem, W.
    Abdelaal, M.
    VALUE IN HEALTH, 2023, 26 (06) : S132 - S133
  • [30] Introduction of microsystems in a level 3 neonatal intensive care unit-an interprofessional approach
    el Helou, Salhab
    Samiee-Zafarghandy, Samira
    Fusch, Gerhard
    Wahab, Muzafar Gani Abdul
    Aliberti, Lynda
    Bakry, Ahmad
    Barnard, Deborah
    Doucette, Joanne
    el Gouhary, Enas
    Marrin, Michael
    Meyer, Carrie-Lynn
    Mukerji, Amit
    Nwebube, Anne
    Pogorzelski, David
    Pugh, Edward
    Schattauer, Karen
    Shah, Jay
    Shivananda, Sandesh
    Thomas, Sumesh
    Twiss, Jennifer
    Williams, Connie
    Dutta, Sourabh
    Fusch, Christoph
    BMC HEALTH SERVICES RESEARCH, 2017, 17