Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems

被引:1
|
作者
Fusch, Gerhard [1 ]
Mohamed, Saber [2 ]
Bakry, Ahmad [1 ]
Li, Edward W. [1 ]
Dutta, Sourabh [1 ,3 ]
Helou, Salhab el [1 ]
Fusch, Christoph [1 ,4 ]
机构
[1] McMaster Univ, Dept Pediat, Div Neonatol, 1280 Main St West, Hamilton, ON L8S 4K1, Canada
[2] McMaster Univ, Dept Mech Engn, Hamilton, ON, Canada
[3] Postgrad Inst Med Educ & Res PGIMER, Dept Pediat, Neonatal Unit, Chandigarh, India
[4] Paracelsus Med Univ Nuremberg, Dept Pediat, Nurnberg, Germany
关键词
Sound pressure; Occupational noise; Environmental exposure; Disorders of environmental origin; SOUND LEVELS; WARD; ROOM;
D O I
10.1007/s00431-023-05335-z
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Reorganization of neonatal intensive care by introducing clinical microsystems may help to allocate nursing time more appropriately to the needs of patients. However, there is concern that cohorting infants according to acuity may enhance noise levels. This single-center study investigated the impact of reorganization of neonatal intensive care unit by implementing clinical microsystems in a Level III NICU on environmental noise. This prospective study measured 24-h noise levels over a period of 6 months during pre- and post-implementation of microsystems cohorting infants of similar acuity. Comparative analyses of the mixed acuity (i.e., before) and the cohorting (i.e., after) model were performed by creating daily profiles from continuous noise level measurements and calculating the length of exposure to predefined noise levels. Compared to baseline daytime measurements, noise levels were 3-6 dBA higher during physician handover. Noise levels were 2-3 dBA lower on weekends and 3-4 dBA lower at night, independent of the organizational model. The introduction of clinical microsystems slightly increased average noise levels for high-acuity pods (A and B) but produced a much more substantial decrease for low-acuity pods (E), leading to an overall reduction in unit-wide noise levels. Conclusion: Our data show that noise levels are more driven by human behavior than by technical devices. Implementation of microsystems may help to reduce noise exposure in the lower acuity pods in a NICU.What is Known:center dot Excessive noise levels can lead to adverse effects on the health and development of premature infants and other critically ill newborns.center dot The reorganization of the neonatal intensive care unit following the clinical microsystems principles might improve quality of care but also affect noise exposure of staff and patients.What is New:center dot The transition from a mixed -acuity to cohorting model is associated with an overall reduction in noise levels, particularly in low-acuity pods requiring less nursing care.center dot Nevertheless, baseline noise levels in both models exceeded the standard permissible limits.
引用
收藏
页码:1245 / 1254
页数:10
相关论文
共 50 条
  • [1] Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems
    Gerhard Fusch
    Saber Mohamed
    Ahmad Bakry
    Edward W. Li
    Sourabh Dutta
    Salhab el Helou
    Christoph Fusch
    European Journal of Pediatrics, 2024, 183 : 1245 - 1254
  • [2] Study of noise levels in a neonatal intensive care unit
    Audiol. Speech-Lang. Pathol. Prog., University of Ottawa, Stn. A, 545 King Edward, P.O. Box 450, Ottawa, Ont. K1N 6N5, Canada
    Can Acoust, 1 (11-19):
  • [3] Analysis of noise in a neonatal intensive care unit
    Guimaraes, H
    Oliveira, AM
    Spratley, J
    Mateus, M
    dOrey, C
    Coelho, JL
    Souto, A
    Santos, NT
    ARCHIVES DE PEDIATRIE, 1996, 3 (11): : 1065 - 1068
  • [4] Internal noise levels in neonatal intensive care unit incubators
    Peixoto, Priscila Vendramini
    Balbino, Flavia Simphronio
    Eliana Moreira Pinheiro, Veridiana Chimirri
    Kakehashi, Tereza Yoshiko
    ACTA PAULISTA DE ENFERMAGEM, 2011, 24 (03) : 359 - 364
  • [5] Noise levels in a neonatal intensive care unit in the Cape metropole
    Nathan, Lisa M.
    Tuomi, Seppo K.
    Muller, Alida M. U.
    Kirsten, Gert F.
    SOUTH AFRICAN JOURNAL OF CHILD HEALTH, 2008, 2 (02) : 50 - 54
  • [6] NOISE-LEVELS IN NEONATAL INTENSIVE-CARE UNIT
    VIDYASAGAR, D
    JOSEPH, ME
    HAMILTON, LR
    JOURNAL OF PEDIATRICS, 1976, 88 (01): : 115 - 115
  • [7] Spectral analysis of noise in the neonatal intensive care unit
    Livera, M. D.
    Priya, B.
    Ramesh, A.
    Rao, P. N. Suman
    Srilakshmi, V.
    Nagapoornima, M.
    Ramakrishnan, A. G.
    Dominic, M.
    Swarnarekha
    INDIAN JOURNAL OF PEDIATRICS, 2008, 75 (03): : 217 - 222
  • [8] Spectral analysis of noise in the neonatal intensive care unit
    M. D. Livera
    B. Priya
    A. Ramesh
    P. N. Suman Rao
    V. Srilakshmi
    M. Nagapoornima
    A. G. Ramakrishnan
    M. Dominic
    The Indian Journal of Pediatrics, 2008, 75
  • [9] The characterization of noise levels in a neonatal intensive care unit and the implications for noise management
    Juan Carlos Fortes-Garrido
    Andres Mauricio Velez-Pereira
    Manuel Gázquez
    Montserrat Hidalgo-Hidalgo
    Juan Pedro Bolívar
    Journal of Environmental Health Science and Engineering, 12
  • [10] The characterization of noise levels in a neonatal intensive care unit and the implications for noise management
    Carlos Fortes-Garrido, Juan
    Mauricio Velez-Pereira, Andres
    Gazquez, Manuel
    Hidalgo-Hidalgo, Montserrat
    Pedro Bolivar, Juan
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2014, 12