Cholesterol oxidase biosensor based on a glassy carbon electrode modified with Nafion and methyl viologen

被引:0
|
作者
JIN
机构
关键词
Biosensor; cholesterol oxidase; enzyme electrode;
D O I
暂无
中图分类号
O657.1 [电化学分析法];
学科分类号
摘要
Cholesterol oxidase biosensor has been constructed by using bovine serum albumin and glutaraldehyde as cross linker to immobilize cholesterol oxidase and cholesterol esterase on a glassy carbon electrode modified with Nafion and methyl viologen. The biosensor has been used to determine total cholesterol in blood. The linear range of the determination is 2.5×10to 1.0×10-4 mol/L. The detection limit is about 5.0×10mol/L. The response time is 12 s. This biosensor has the advantage of high selectivity, sensitivity and short response time.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 50 条
  • [41] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [42] A salivary glucose biosensor based on immobilization of glucose oxidase in Nafion-carbon nanotubes nanocomposites modified on screen printed electrode
    Liu, Chung-Tzu
    Liu, Ching-Hao
    Lai, Yi-Ting
    Lee, Chi-Young
    Gupta, Shivam
    Tai, Nyan-Hwa
    MICROCHEMICAL JOURNAL, 2023, 191
  • [43] Selective determination of dopamine with an amperometric biosensor using electrochemically pretreated and activated carbon/tyrosinase/Nafion®-modified glassy carbon electrode
    Siti Fauziyah Rahman
    Kyoungseon Min
    Seok-Hwan Park
    Jae-Hee Park
    Jin Cheol Yoo
    Don-Hee Park
    Biotechnology and Bioprocess Engineering, 2016, 21 : 627 - 633
  • [44] An enhanced direct electrochemistry of glucose oxidase at poly(taurine) modified glassy carbon electrode for glucose biosensor
    Madhu, Rajesh
    Devadas, Balamurugan
    Chen, Shen Ming
    Rajkumar, Muniyandi
    ANALYTICAL METHODS, 2014, 6 (22) : 9053 - 9058
  • [45] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015
  • [46] Development of a stable biosensor based on a SiO2 nanosheet-Nafion-modified glassy carbon electrode for sensitive detection of pesticides
    Yang, Long
    Wang, Guang-Can
    Liu, Yong-Jun
    An, Jing-Jing
    Wang, Min
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (08) : 2545 - 2552
  • [47] Nafion-modified glassy carbon electrode for trace determination of indium
    Xiang, CL
    Zou, YJ
    Xie, JJ
    Fei, XM
    Li, JH
    ANALYTICAL LETTERS, 2005, 38 (13) : 2045 - 2055
  • [48] Glucose biosensor based on multi-walled carbon nanotube modified glassy carbon electrode
    Dai, YQ
    Shiu, KK
    ELECTROANALYSIS, 2004, 16 (20) : 1697 - 1703
  • [49] Conductometric nitrate biosensor based on methyl viologen/Nafion®/nitrate reductase interdigitated electrodes
    Wang, XJ
    Dzyadevych, SV
    Chovelon, JM
    Renault, NJ
    Ling, C
    Xia, SQ
    Zhao, JF
    TALANTA, 2006, 69 (02) : 450 - 455
  • [50] An ECL biosensor for glucose based on carbon-nanotube/Nafion film modified glass carbon electrode
    Lin, Zhenyu
    Chen, Jinhua
    Chen, Guonan
    ELECTROCHIMICA ACTA, 2008, 53 (05) : 2396 - 2401