Cholesterol oxidase biosensor based on a glassy carbon electrode modified with Nafion and methyl viologen

被引:0
|
作者
JIN
机构
关键词
Biosensor; cholesterol oxidase; enzyme electrode;
D O I
暂无
中图分类号
O657.1 [电化学分析法];
学科分类号
摘要
Cholesterol oxidase biosensor has been constructed by using bovine serum albumin and glutaraldehyde as cross linker to immobilize cholesterol oxidase and cholesterol esterase on a glassy carbon electrode modified with Nafion and methyl viologen. The biosensor has been used to determine total cholesterol in blood. The linear range of the determination is 2.5×10to 1.0×10-4 mol/L. The detection limit is about 5.0×10mol/L. The response time is 12 s. This biosensor has the advantage of high selectivity, sensitivity and short response time.
引用
收藏
页码:343 / 347
页数:5
相关论文
共 50 条
  • [31] Development of a conductometric nitrate biosensor based on Methyl viologen/Nafion® composite film
    Wang, XJ
    Dzyadevych, SV
    Chovelon, JM
    Renault, NJ
    Chen, L
    Xia, SQ
    Zhao, JF
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (02) : 201 - 205
  • [32] Xanthine oxidase modified glassy carbon paste electrode
    Anik, U
    Timur, S
    Wang, J
    Telefoncu, A
    ELECTROCHEMISTRY COMMUNICATIONS, 2004, 6 (09) : 913 - 916
  • [33] A novel electrochemiluminescence glucose biosensor based on platinum nanoflowers/graphene oxide/glucose oxidase modified glassy carbon electrode
    Xiaotian Tian
    Sai Lian
    Limin Zhao
    Xiaomei Chen
    Zhiyong Huang
    Xi Chen
    Journal of Solid State Electrochemistry, 2014, 18 : 2375 - 2382
  • [34] Unadulterated glucose biosensor based on direct electron transfer of glucose oxidase encapsulated chitosan modified glassy carbon electrode
    Zhao, Changzhi
    Meng, Yi
    Shao, Changli
    Wan, Li
    Jiao, Kui
    ELECTROANALYSIS, 2008, 20 (05) : 520 - 526
  • [35] A novel electrochemiluminescence glucose biosensor based on platinum nanoflowers/graphene oxide/glucose oxidase modified glassy carbon electrode
    Tian, Xiaotian
    Lian, Sai
    Zhao, Limin
    Chen, Xiaomei
    Huang, Zhiyong
    Chen, Xi
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2014, 18 (09) : 2375 - 2382
  • [36] Amperometric glucose biosensor based on immobilization of glucose oxidase on a magnetic glassy carbon electrode modified with a novel magnetic nanocomposite
    Baghayeri, Mehdi
    Veisi, Hojat
    Ghanei-Motlagh, Masoud
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 249 : 321 - 330
  • [37] Hydrogen peroxide biosensor based on horseradish peroxidase–Au nanoparticles at a viologen grafted glassy carbon electrode
    Jianbo Jia
    Microchimica Acta, 2008, 163 : 237 - 241
  • [38] Glucose Biosensor Based on Glucose Oxidase Immobilized on BSA Cross-Linked Nanocomposite Modified Glassy Carbon Electrode
    Li, Yang-Yang
    Ma, Xin-Xin
    Song, Xin-Yan
    Ma, Lin-Lin
    Li, Yu-Ying
    Meng, Xin
    Chen, Yu-Jie
    Xu, Ke-Xin
    Moosavi-Movahedi, Ali Akbar
    Xiao, Bao-Lin
    Hong, Jun
    SENSORS, 2023, 23 (06)
  • [39] Electrochemical Sensor for Caffeine Based on a Glassy Carbon Electrode Modified with an Attapulgite/Nafion Film
    Tajeu, Kevin Yemele
    Ymele, Ervice
    Jiokeng, Sherman Lesly Zambou
    Tonle, Ignas Kenfack
    ELECTROANALYSIS, 2019, 31 (02) : 350 - 356
  • [40] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390