Effect of 2% fluorescein on Scheimpflug central corneal thickness measurements

被引:0
|
作者
Stella Briggs [1 ]
Marwa Bin Moammar [2 ]
机构
[1] College of Applied Medical Sciences, King Saud University
[2] Ophthalmology Clinic, Security Forces Hospital
关键词
central corneal thickness; fluorescein; Scheimpflug device;
D O I
暂无
中图分类号
R770.4 [眼科诊断学];
学科分类号
100212 ;
摘要
AIM: To assess central corneal thickness(CCT)changes measured with Scheimpflug device following instillation of 2% fluorescein in normal subjects.·METHODS: This was a prospective randomized study of 60 hospital volunteers. After baseline CCT measurements of both eyes of 40 subjects were obtained using Scheimpflug system, a drop of preservative-free2% fluorescein, was instilled in one eye and in other eye,one drop of normal saline(control). Measurements were repeated after 1, 2, 5, 10, 20, 30, 40, 50 and 60min(continuous assessment group). Twenty subjects had baseline CCT taken, then fluorescein was instilled in one eye and measurements were taken at 1min. Ten eyes had saline rinse after 1min and 10 other eyes did not,measurements were repeated at 2min(eye rinse group).· RESULTS: The mean baseline CCT for continuous assessment group was 546.2±32.1 μm(range, 489.0-606.0),control eyes was 546.6±30.7 μm(range, 489.0-602.0). At1 min after fluorescein instillation, CCT significantly increased by 37.0 ±34.0 μm(P <0.001), then decreased gradually, reaching baseline at 60 min. CCT variations were not significant in control group(P >0.05). For eye rinse group, CCT mean differences between baseline and 2min were 18.2 μm(95 % CI:-54.7 to 18.3) with rinse and 26.5 μm(95% CI:-62.9 to 9.9) without rinse; paired sample tests were not significant(P >0.05).·CONCLUSION: The presence of fluorescein increased CCT value to a clinically relevant level of 6.8%. Eye rinse did not significantly reduce the effect at 2min post fluorescein timepoint.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [31] Central corneal thickness measurements after myopic photorefractive keratectomy using Scheimpflug imaging, scanning-slit topography, and ultrasonic pachymetry
    Faramarzi, Amir
    Karimian, Farid
    Jafarinasab, Mohammad Reza
    Bonyadi, Mohammad Hossein Jabbarpoor
    Yaseri, Mehdi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (09): : 1543 - 1549
  • [32] Comparison of In Vivo Confocal Microscopy, Ultrasonic Pachymetry, and Scheimpflug Topography for Measuring Central Corneal Thickness
    MeenakshiSundaram, Soundaram
    Sufi, Aalia Rasool
    Prajna, N. Venkatesh
    Keenan, Jeremy D.
    JAMA OPHTHALMOLOGY, 2016, 134 (09) : 1057 - 1059
  • [33] The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging
    Yune Zhao
    Ding Chen
    Giacomo Savini
    Qing Wang
    Hongfang Zhang
    Yili Jin
    Benhao Song
    Rui Ning
    Jinhai Huang
    Chenyang Mei
    Eye and Vision, 7
  • [34] Repeatability of Central Corneal Thickness Measurement Using Rotating Scheimpflug Camera in Dry and Normal Eyes
    Lee, Jong-Hyuck
    Kim, Jae Hyuk
    Kim, Sun Woong
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S29 - S32
  • [35] Sirius Scheimpflug–Placido versus ultrasound pachymetry for central corneal thickness: meta-analysis
    Yili Jin
    Colm McAlinden
    Yong Sun
    Daizong Wen
    Yiran Wang
    Jinjin Yu
    Ke Feng
    Benhao Song
    Qinmei Wang
    Shihao Chen
    Jinhai Huang
    Eye and Vision, 8
  • [36] Preliminary topographic analysis of the corneal thickness with scheimpflug camera
    Inohara, H
    Maeda, N
    Kiritoshi, A
    Watanabe, H
    Shimomura, Y
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 2574 - 2574
  • [37] Central corneal thickness and anterior chamber depth measurement by Sirius (R) Scheimpflug tomography and ultrasound
    Jorge, J.
    Rosado, J. L.
    Diaz-Rey, J. A.
    Gonzalez-Meijome, J. M.
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 417 - 422
  • [38] Reproducibility, Repeatability, and Correlation of Central Corneal Thickness Measurement with the Pentacam Scheimpflug System and Ultrasound Pachymetry
    Macias-Rodriguez, Yolanda
    Ramos-Davila, Eugenia M.
    Ruiz-Lozano, Raul E.
    Reyes-Arena, Jose, V
    Jocelyn Rivera-Alvarado, I
    Hernandez-Camarena, Julio C.
    Rodriguez-Garcia, Alejandro
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2024, 241 (11) : 1238 - 1244
  • [39] The precision and agreement of corneal thickness and keratometry measurements with SS-OCT versus Scheimpflug imaging
    Zhao, Yune
    Chen, Ding
    Savini, Giacomo
    Wang, Qing
    Zhang, Hongfang
    Jin, Yili
    Song, Benhao
    Ning, Rui
    Huang, Jinhai
    Mei, Chenyang
    EYE AND VISION, 2020, 7 (01)
  • [40] Corneal anthropology: Ethnicity-based central corneal thickness measurements in managing corneal disorders
    Sharma, Rajan
    Sharma, Ashok
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (05) : 1338 - 1338