Effect of 2% fluorescein on Scheimpflug central corneal thickness measurements

被引:0
|
作者
Stella Briggs [1 ]
Marwa Bin Moammar [2 ]
机构
[1] College of Applied Medical Sciences, King Saud University
[2] Ophthalmology Clinic, Security Forces Hospital
关键词
central corneal thickness; fluorescein; Scheimpflug device;
D O I
暂无
中图分类号
R770.4 [眼科诊断学];
学科分类号
100212 ;
摘要
AIM: To assess central corneal thickness(CCT)changes measured with Scheimpflug device following instillation of 2% fluorescein in normal subjects.·METHODS: This was a prospective randomized study of 60 hospital volunteers. After baseline CCT measurements of both eyes of 40 subjects were obtained using Scheimpflug system, a drop of preservative-free2% fluorescein, was instilled in one eye and in other eye,one drop of normal saline(control). Measurements were repeated after 1, 2, 5, 10, 20, 30, 40, 50 and 60min(continuous assessment group). Twenty subjects had baseline CCT taken, then fluorescein was instilled in one eye and measurements were taken at 1min. Ten eyes had saline rinse after 1min and 10 other eyes did not,measurements were repeated at 2min(eye rinse group).· RESULTS: The mean baseline CCT for continuous assessment group was 546.2±32.1 μm(range, 489.0-606.0),control eyes was 546.6±30.7 μm(range, 489.0-602.0). At1 min after fluorescein instillation, CCT significantly increased by 37.0 ±34.0 μm(P <0.001), then decreased gradually, reaching baseline at 60 min. CCT variations were not significant in control group(P >0.05). For eye rinse group, CCT mean differences between baseline and 2min were 18.2 μm(95 % CI:-54.7 to 18.3) with rinse and 26.5 μm(95% CI:-62.9 to 9.9) without rinse; paired sample tests were not significant(P >0.05).·CONCLUSION: The presence of fluorescein increased CCT value to a clinically relevant level of 6.8%. Eye rinse did not significantly reduce the effect at 2min post fluorescein timepoint.
引用
收藏
页码:239 / 242
页数:4
相关论文
共 50 条
  • [21] The effect of corneal thickness and corneal curvature on pneumatonometer measurements
    Morgan, AJ
    Harper, J
    Hosking, SL
    Gilmartin, B
    CURRENT EYE RESEARCH, 2002, 25 (02) : 107 - 112
  • [22] Central Corneal Thickness Measurements With Fourier-Domain Optical Coherence Tomography Versus Ultrasonic Pachymetry and Rotating Scheimpflug Camera
    Ishibazawa, Akihiro
    Igarashi, Sho
    Hanada, Kazuomi
    Nagaoka, Taiji
    Ishiko, Satoshi
    Ito, Haruna
    Yoshida, Akitoshi
    CORNEA, 2011, 30 (06) : 615 - 619
  • [23] Effect of Brimonidine on Central Corneal Thickness
    Grueb, M.
    Mielke, J.
    Schlote, T.
    Rohrbach, M.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2012, 229 (03) : 236 - 240
  • [24] The effect of latanoprost on central corneal thickness
    Booth, AP
    Pappas, G
    Achar, A
    Menon, JK
    Sanders, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [25] The Effect of Central Corneal Thickness on Tonometry
    Boehm, A. G.
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2011, 228 (02) : 114 - 117
  • [26] Effect of timolol on central corneal thickness
    Grueb, Matthias
    Rohrbach, Jens Martin
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (06) : 784 - 788
  • [27] Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT
    Kuerten, David
    Plange, Niklas
    Koch, Eva Charlotte
    Koutsonas, Antonis
    Walter, Peter
    Fuest, Matthias
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (07) : 1105 - 1109
  • [28] Central corneal thickness determination in corneal edema using ultrasound pachymetry, a Scheimpflug camera, and anterior segment OCT
    David Kuerten
    Niklas Plange
    Eva Charlotte Koch
    Antonis Koutsonas
    Peter Walter
    Matthias Fuest
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2015, 253 : 1105 - 1109
  • [29] Repeatability and agreement of 2 Scheimpflug analyzers in measuring the central corneal thickness and anterior chamber angle, volume, and depth
    Bedei, Andrea
    Appolloni, Ilaria
    Madesani, Antonio
    Pietrelli, Alessia
    Franceschi, Sara
    Barabesi, Lucio
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 : S29 - S32
  • [30] Evaluation of Central Corneal Thickness Using Corneal Dynamic Scheimpflug Analyzer Corvis ST and Comparison with Pentacam Rotating Scheimpflug System and Ultrasound Pachymetry in Normal Eyes
    Yu, Ayong
    Zhao, Weiqi
    Savini, Giacomo
    Huang, Zixu
    Bao, Fangjun
    Lu, Weicong
    Wang, Qinmei
    Huang, Jinhai
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015