IN—SITU MEASUREMENTS OF RADON EXHALATION RATE FROM BUILDING SURFACE IN HONG KONG

被引:0
|
作者
余君岳
关祖杰
杨健明
M.J.Stokes
机构
[1] City Polytechnic of Hong Kong
[2] Zhongshan University Guangzhou 510275
关键词
Charcoal canisters Radon exhalation rate Building surfaces Building materials;
D O I
暂无
中图分类号
学科分类号
摘要
EPA-standardized activated charcoal canisters were used to collect radon exhaled from building surfaces and analyzed using γ-spectroscopy to obtain the radon exhalation rates. More than 120 samples were analyzed in more than 10 buildings situated in different areas of Hong Kong. Variations were identified in the exhalation rates at different levels in a building, for different covering materials and for the presence of cracks in walls. The radon exhalation rate from the most common concrete walls and covering materials was found to be approximately 13 mBq·m·s. This may be the cause of a relatively high indoor radon concentration in Hong Kong.
引用
收藏
页码:176 / 180
页数:5
相关论文
共 50 条
  • [31] Radon and thoron exhalation rate from building materials: experimental evaluations and theoretical models
    Magnoni, Mauro
    Chiaberto, Enrico
    Serena, Elena
    EUROPEAN PHYSICAL JOURNAL PLUS, 2024, 139 (01):
  • [32] Measurement of radon exhalation rate from building materials: The case of Highland Region of Ecuador
    Tene, Talia
    Vacacela Gomez, Cristian
    Tubon Usca, Gabriela
    Suquillo, Betzabeth
    Bellucci, Stefano
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 293
  • [33] Radon and thoron exhalation rate from building materials: experimental evaluations and theoretical models
    Mauro Magnoni
    Enrico Chiaberto
    Elena Serena
    The European Physical Journal Plus, 139
  • [34] In situ measurements of radon levels in water and soil and exhalation rate in areas of Malwa belt of Punjab (India)
    Kumar, Sanjeev
    Singh, Surinder
    Bajwa, Bikramjit S.
    Sabharwal, Arvind D.
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2011, 47 (04) : 446 - 455
  • [35] A simple model for automatically measuring radon exhalation rate from medium surface
    Tan, Yanliang
    Xiao, Detao
    RADIATION MEASUREMENTS, 2014, 64 : 44 - 47
  • [36] Setup and procedure for routine measurements of radon exhalation rates of building materials
    Al-Azmi, D.
    Okeyode, I. C.
    Alatise, O. O.
    Mustapha, A. O.
    RADIATION MEASUREMENTS, 2018, 112 : 6 - 10
  • [37] RADON EXHALATION FROM BUILDING MATERIALS USED IN YEMEN
    Al Mugahed, Murad
    Bentayeb, Farida
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (04) : 405 - 412
  • [38] Radon exhalation from building materials for decorative use
    Chen, Jing
    Rahman, Naureen M.
    Abu Atiya, Ibrahim
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2010, 101 (04) : 317 - 322
  • [39] Radon exhalation rate in south-east Sicily building materials
    D. Morelli
    R. Catalano
    R. Filincieri
    G. Immé
    G. Mangano
    The European Physical Journal Special Topics, 2015, 224 : 605 - 610
  • [40] Radon exhalation rate in building materials using plastic track detectors
    D. Amrani
    D. E. Cherouati
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 269 - 271