IN—SITU MEASUREMENTS OF RADON EXHALATION RATE FROM BUILDING SURFACE IN HONG KONG

被引:0
|
作者
余君岳
关祖杰
杨健明
M.J.Stokes
机构
[1] City Polytechnic of Hong Kong
[2] Zhongshan University Guangzhou 510275
关键词
Charcoal canisters Radon exhalation rate Building surfaces Building materials;
D O I
暂无
中图分类号
学科分类号
摘要
EPA-standardized activated charcoal canisters were used to collect radon exhaled from building surfaces and analyzed using γ-spectroscopy to obtain the radon exhalation rates. More than 120 samples were analyzed in more than 10 buildings situated in different areas of Hong Kong. Variations were identified in the exhalation rates at different levels in a building, for different covering materials and for the presence of cracks in walls. The radon exhalation rate from the most common concrete walls and covering materials was found to be approximately 13 mBq·m·s. This may be the cause of a relatively high indoor radon concentration in Hong Kong.
引用
收藏
页码:176 / 180
页数:5
相关论文
共 50 条
  • [21] EU-Concerted Action for a survey on radon exhalation rate measurements for building materials and soils
    Roelofs, L
    Wiegers, R
    Puch, KH
    Keller, G
    Natural Radiation Environment VII, 2005, 7 : 512 - 519
  • [22] Simultaneous measurement of radon and thoron exhalation rate from soil and building materials
    Cosma, C
    Cozar, O
    Jurcut, T
    Baciu, C
    Pop, I
    NATURAL RADIATION ENVIRONMENT VII, 2005, 7 : 699 - 705
  • [23] Estimation of the radon dose in buildings by measuring the exhalation rate from building materials
    Steiner, V
    Kovler, K
    Perevalov, A
    Kelm, H
    HIGH LEVELS OF NATURAL RADIATION AND RADON AREAS: RADIATION DOSE AND HEALTH EFFECTS, 2005, 1276 : 397 - 398
  • [24] Modeling of indoor radon concentration from radon exhalation rates of building materials and validation through measurements
    Kumar, Amit
    Chauhan, R. P.
    Joshi, Manish
    Sahoo, B. K.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2014, 127 : 50 - 55
  • [25] Complementary system for long term measurements of radon exhalation rate from soil
    Mazur, J.
    Kozak, K.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (02):
  • [26] Influence of humidity on building material's radon exhalation rate
    Ji, Dong
    Xu, Zhongyang
    Zhang, Yuntao
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING II, PTS 1-3, 2013, 433-435 : 2085 - +
  • [27] Exhalation rate study of radon/thoron in some building materials
    Sharma, N
    Virk, HS
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 467 - 469
  • [28] Radon Exhalation Rate of Some Building Materials Used in Egypt
    A.F. Maged
    F.A. Ashraf
    Environmental Geochemistry and Health, 2005, 27 : 485 - 489
  • [29] Radon exhalation rate of some building materials used in Egypt
    Maged, AF
    Ashraf, FA
    ENVIRONMENTAL GEOCHEMISTRY AND HEALTH, 2005, 27 (5-6) : 485 - 489
  • [30] QUANTIFICATION OF BACK DIFFUSION IN RADON AND THORON EXHALATION RATE MEASUREMENTS
    Chitra, N.
    Sundar, S. Bala
    Subramanian, V
    Jose, M. T.
    Baskaran, R.
    Venkatraman, B.
    RADIATION PROTECTION DOSIMETRY, 2020, 189 (02) : 182 - 189