Excellent long-term device survival of inflatable penile prosthesis over 27 years

被引:0
|
作者
Moncada, Ignacio [1 ]
Krishnappa, Pramod [1 ,2 ]
Martinez-Salamanca, Juan Ignacio [3 ,4 ]
Palma-Hendges, Luiz Pedro [3 ]
Gonzalez-Garcia, Francisco Javier [3 ]
Hernandez-Fernandez, Carlos [5 ]
Lledo-Garcia, Enrique [5 ]
机构
[1] La Zarzuela Univ Hosp, Dept Urol & Robot Surg, Madrid 28023, Spain
[2] NU Hosp, Dept Urol & Robot Surg, Androl Div, AndroNeo,Orchidz Hlth, Bengaluru 560010, Karnataka, India
[3] Francisco Vitoria Univ, Lyx Inst Urol, Madrid 28006, Spain
[4] Puerta De Hierro Majadahonda Univ Hosp, Dept Urol, Madrid 28222, Spain
[5] Univ Complutense Madrid, Gregorio Maranon Univ Gen Hosp, Dept Urol, Madrid 28007, Spain
来源
关键词
device survival; erectile dysfunction; infection; mechanical failure; penile prosthesis; ERECTILE DYSFUNCTION; INFECTION; IMPLANTATION; OUTCOMES; INHIBITORS; EFFICACY; RISK; MEN; AUA;
D O I
10.4103/aja2024112
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
The study aimed to assess the long-term device survival of a 3-piece inflatable penile prosthesis (PP) in patients with erectile dysfunction (ED). This retrospective observational longitudinal study involved patients with drug-refractory ED who underwent primary 3-piece inflatable PP implantation at a single center from 1992 to 2019. The outcomes included complications of various inflatable PP models, and Kaplan-Meier analysis was used to estimate the probability of PP survival. Of the total 426 patients, 140 (32.9%) were implanted in the period of 1992-2000, 128 (30.0%) in the period of 2001-2008, and 158 (37.1%) in the period of 2009-2019. The PP used in the study included AMS 700 CX (62.0%, n = 264), AMS 700 CXR (7.7%, n = 33), AMS Ultrex Plus (10.3%, n = 44), and Alpha I (20.0%, n = 85). The overall complication rate was 28.2% (120/426), and the majority happened after 6 months. The causes of device removal included mechanical failure (11.0%, n = 47), infection (3.9%, n = 17), cylinder extrusion (6.3%, n = 27), and unspecified (0.2%, n = 1). Of the total mechanical failures (n = 47), 18 (38.3%) occurred in the cylinders, 10 (21.3%) occurred in the pump, 7 (14.9%) occurred in the reservoir, 6 (12.8%) occurred in the connections, and 6 (12.8%) were nonspecific. Global average survival rates of the PP at 1 year, 5 years, 10 years, and 15 years were 96.2%, 86.7%, 77.5%, and 58.7%, respectively. The 3-piece inflatable PP has an excellent device survival rate at 5 years and 10 years.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Long-term experience with AMS-700 CXR inflatable penile prosthesis in high-risk patients with corporal fibrosis
    Johnson, Blake E.
    Langford, Brian T.
    VanDyke, Maia E.
    Matz, Ethan L.
    Cook, Grayden S.
    Franzen, Bryce P.
    Morey, Allen F.
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2025, 37 (01) : 66 - 71
  • [42] Re: Long-Term Sequelae of Inflatable Penile Prosthesis: Clinical Characteristics of Patients Who Develop Distal Cylinder Tip Extrusion
    Seftel, Allen D.
    JOURNAL OF UROLOGY, 2021, 205 (03): : 913 - 914
  • [43] Excellent Long-Term Survival After Weaning from Durable Ventricular Assist Device
    Ono, M.
    Kinoshita, O.
    Ando, M.
    Gyoten, T.
    Ishida, J.
    Amiya, E.
    Hatano, M.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2022, 41 (04): : S189 - S190
  • [44] CLINICAL EXPERIENCE AND RESULTS OF 27 YEARS IN PENILE PROSTHESIS
    Ibis, A.
    Yaman, O.
    Gokce, I
    JOURNAL OF SEXUAL MEDICINE, 2019, 16 (04): : S99 - S99
  • [45] Long term patient satisfaction and quality of life with AMS700CX inflatable penile prosthesis
    Vitarelli, Antonio
    Divenuto, Lucia
    Fortunato, Francesca
    Falco, Antonio
    Pagliarulo, Vincenzo
    Antonini, Gabriele
    Gentile, Vincenzo
    Sciarra, Alessandro
    Salciccia, Stefano
    Sansalone, Salvatore
    Di Placido, Maria Rosaria
    Garaffa, Giulio
    Pagliarulo, Arcangelo
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2013, 85 (03) : 133 - 137
  • [46] INFLATABLE PENILE PROSTHESIS - NEW DEVICE DESIGN AND PATIENT-PARTNER SATISFACTION
    FURLOW, WL
    BARRETT, DM
    UROLOGY, 1984, 24 (06) : 559 - 563
  • [47] Long-term results with hydroflex and dynaflex penile prostheses: Device survival comparison to multicomponent inflatables
    Wilson, SK
    Cleves, M
    Delk, JR
    JOURNAL OF UROLOGY, 1996, 155 (05): : 1621 - 1623
  • [48] AMS 700CX/CXM Inflatable Penile Prosthesis Has High Mechanical Reliability at Long-Term Follow-Up
    Kim, Dong Suk
    Yang, Kwang Mo
    Chung, Hyun Jin
    Choi, Hyun Min
    Choi, Young Deuk
    Choi, Hyung Ki
    JOURNAL OF SEXUAL MEDICINE, 2010, 7 (07): : 2602 - 2607
  • [49] Efficacy, safety and patient satisfaction outcomes of the AMS 700CX inflatable penile prosthesis: Results of a long-term multicenter study
    Carson, CC
    Mulcahy, JJ
    Govier, FE
    JOURNAL OF UROLOGY, 2000, 164 (02): : 376 - 380
  • [50] Commentary on: Long-term experience with AMS-700 CXR inflatable penile prosthesis in high-risk patients with corporal fibrosis
    Rowaiee, Rashed
    Almidani, Omar
    Raheem, Omer A.
    INTERNATIONAL JOURNAL OF IMPOTENCE RESEARCH, 2024,