Excellent long-term device survival of inflatable penile prosthesis over 27 years

被引:0
|
作者
Moncada, Ignacio [1 ]
Krishnappa, Pramod [1 ,2 ]
Martinez-Salamanca, Juan Ignacio [3 ,4 ]
Palma-Hendges, Luiz Pedro [3 ]
Gonzalez-Garcia, Francisco Javier [3 ]
Hernandez-Fernandez, Carlos [5 ]
Lledo-Garcia, Enrique [5 ]
机构
[1] La Zarzuela Univ Hosp, Dept Urol & Robot Surg, Madrid 28023, Spain
[2] NU Hosp, Dept Urol & Robot Surg, Androl Div, AndroNeo,Orchidz Hlth, Bengaluru 560010, Karnataka, India
[3] Francisco Vitoria Univ, Lyx Inst Urol, Madrid 28006, Spain
[4] Puerta De Hierro Majadahonda Univ Hosp, Dept Urol, Madrid 28222, Spain
[5] Univ Complutense Madrid, Gregorio Maranon Univ Gen Hosp, Dept Urol, Madrid 28007, Spain
来源
关键词
device survival; erectile dysfunction; infection; mechanical failure; penile prosthesis; ERECTILE DYSFUNCTION; INFECTION; IMPLANTATION; OUTCOMES; INHIBITORS; EFFICACY; RISK; MEN; AUA;
D O I
10.4103/aja2024112
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
The study aimed to assess the long-term device survival of a 3-piece inflatable penile prosthesis (PP) in patients with erectile dysfunction (ED). This retrospective observational longitudinal study involved patients with drug-refractory ED who underwent primary 3-piece inflatable PP implantation at a single center from 1992 to 2019. The outcomes included complications of various inflatable PP models, and Kaplan-Meier analysis was used to estimate the probability of PP survival. Of the total 426 patients, 140 (32.9%) were implanted in the period of 1992-2000, 128 (30.0%) in the period of 2001-2008, and 158 (37.1%) in the period of 2009-2019. The PP used in the study included AMS 700 CX (62.0%, n = 264), AMS 700 CXR (7.7%, n = 33), AMS Ultrex Plus (10.3%, n = 44), and Alpha I (20.0%, n = 85). The overall complication rate was 28.2% (120/426), and the majority happened after 6 months. The causes of device removal included mechanical failure (11.0%, n = 47), infection (3.9%, n = 17), cylinder extrusion (6.3%, n = 27), and unspecified (0.2%, n = 1). Of the total mechanical failures (n = 47), 18 (38.3%) occurred in the cylinders, 10 (21.3%) occurred in the pump, 7 (14.9%) occurred in the reservoir, 6 (12.8%) occurred in the connections, and 6 (12.8%) were nonspecific. Global average survival rates of the PP at 1 year, 5 years, 10 years, and 15 years were 96.2%, 86.7%, 77.5%, and 58.7%, respectively. The 3-piece inflatable PP has an excellent device survival rate at 5 years and 10 years.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Long-term followup of and patient satisfaction with the dynaflex self-contained inflatable penile prosthesis - Editorial Comment
    Mulcahy, JJ
    JOURNAL OF UROLOGY, 1997, 158 (02): : 459 - 459
  • [32] REVISED SURGICAL TECHNIQUE TO IMPROVE SURVIVAL OF PENILE CYLINDERS FOR THE INFLATABLE PENILE PROSTHESIS
    MALLOY, TR
    WEIN, AJ
    CARPINIELLO, VL
    JOURNAL OF UROLOGY, 1983, 130 (06): : 1105 - 1106
  • [33] LONG-TERM RESULTS WITH THE JONAS MALLEABLE PENILE PROSTHESIS
    BENSON, RC
    PATTERSON, DE
    BARRETT, DM
    JOURNAL OF UROLOGY, 1985, 134 (05): : 899 - 901
  • [34] COMPARATIVE ANALYSIS OF LONG-TERM OUTCOMES OF TWO-PIECE VERSUS THREE-PIECE INFLATABLE PENILE PROSTHESIS
    Kim, J.
    Greenberg, J.
    Dick, B.
    Soubra, A.
    Hellstrom, W.
    Raheem, O.
    JOURNAL OF SEXUAL MEDICINE, 2021, 18 (03): : S82 - S82
  • [35] Long-term sequelae of inflatable penile prosthesis: clinical characteristics of patients who develop distal cylinder tip extrusion
    Fuentes, Jorge L.
    Yi, Yooni A.
    Davenport, Michael T.
    Bergeson, Rachel L.
    Ward, Ellen E.
    Morey, Allen F.
    TRANSLATIONAL ANDROLOGY AND UROLOGY, 2020, 9 (01) : 38 - 42
  • [36] Tubing Erosion of an Inflatable Penile Prosthesis Long after Implantation
    Morales, Alvaro
    SEXUAL MEDICINE, 2014, 2 (02): : 103 - 106
  • [37] THE INFLATABLE PENILE PROSTHESIS - THE CASE FOR THE MEDICAL DEVICE DATA-BASE
    FURLOW, WL
    JOURNAL OF UROLOGY, 1985, 133 (01): : 72 - 72
  • [38] LONG-TERM COMPLICATIONS FREE SURVIVAL AND RISK FACTORS FOR REINTERVENTION AFTER PENILE PROSTHESIS IMPLANTATION
    Zouari, Skander
    Mendel, Lionel
    Barthe, Flora
    Morrone, Arnoult
    Gonima, Paula Lorena Charry
    Haider, Romain
    Ahallal, Younes
    Durand, Matthieu
    Chevallier, Daniel
    Bentellis, Imad
    JOURNAL OF UROLOGY, 2024, 211 (05): : E976 - E976
  • [39] Technological Improvements in Three-Piece Inflatable Penile Prosthesis Design over the Past 40 Years
    Pastuszak, Alexander W.
    Lentz, Aaron C.
    Farooq, Ahmer
    Jones, Leroy
    Bella, Anthony J.
    JOURNAL OF SEXUAL MEDICINE, 2015, 12 : 415 - 421
  • [40] PENILE MODELING MAY IMPACT DEVICE FAILURE IN PATIENTS UNDERGOING INFLATABLE PENILE PROSTHESIS PLACEMENT
    Warner, Jonathan
    Tyson, Mark
    Chen, Catherine
    Woler, Christopher
    JOURNAL OF SEXUAL MEDICINE, 2012, 9 : 61 - 61