Excellent long-term device survival of inflatable penile prosthesis over 27 years

被引:0
|
作者
Moncada, Ignacio [1 ]
Krishnappa, Pramod [1 ,2 ]
Martinez-Salamanca, Juan Ignacio [3 ,4 ]
Palma-Hendges, Luiz Pedro [3 ]
Gonzalez-Garcia, Francisco Javier [3 ]
Hernandez-Fernandez, Carlos [5 ]
Lledo-Garcia, Enrique [5 ]
机构
[1] La Zarzuela Univ Hosp, Dept Urol & Robot Surg, Madrid 28023, Spain
[2] NU Hosp, Dept Urol & Robot Surg, Androl Div, AndroNeo,Orchidz Hlth, Bengaluru 560010, Karnataka, India
[3] Francisco Vitoria Univ, Lyx Inst Urol, Madrid 28006, Spain
[4] Puerta De Hierro Majadahonda Univ Hosp, Dept Urol, Madrid 28222, Spain
[5] Univ Complutense Madrid, Gregorio Maranon Univ Gen Hosp, Dept Urol, Madrid 28007, Spain
来源
关键词
device survival; erectile dysfunction; infection; mechanical failure; penile prosthesis; ERECTILE DYSFUNCTION; INFECTION; IMPLANTATION; OUTCOMES; INHIBITORS; EFFICACY; RISK; MEN; AUA;
D O I
10.4103/aja2024112
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
The study aimed to assess the long-term device survival of a 3-piece inflatable penile prosthesis (PP) in patients with erectile dysfunction (ED). This retrospective observational longitudinal study involved patients with drug-refractory ED who underwent primary 3-piece inflatable PP implantation at a single center from 1992 to 2019. The outcomes included complications of various inflatable PP models, and Kaplan-Meier analysis was used to estimate the probability of PP survival. Of the total 426 patients, 140 (32.9%) were implanted in the period of 1992-2000, 128 (30.0%) in the period of 2001-2008, and 158 (37.1%) in the period of 2009-2019. The PP used in the study included AMS 700 CX (62.0%, n = 264), AMS 700 CXR (7.7%, n = 33), AMS Ultrex Plus (10.3%, n = 44), and Alpha I (20.0%, n = 85). The overall complication rate was 28.2% (120/426), and the majority happened after 6 months. The causes of device removal included mechanical failure (11.0%, n = 47), infection (3.9%, n = 17), cylinder extrusion (6.3%, n = 27), and unspecified (0.2%, n = 1). Of the total mechanical failures (n = 47), 18 (38.3%) occurred in the cylinders, 10 (21.3%) occurred in the pump, 7 (14.9%) occurred in the reservoir, 6 (12.8%) occurred in the connections, and 6 (12.8%) were nonspecific. Global average survival rates of the PP at 1 year, 5 years, 10 years, and 15 years were 96.2%, 86.7%, 77.5%, and 58.7%, respectively. The 3-piece inflatable PP has an excellent device survival rate at 5 years and 10 years.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] LONG-TERM INFECTION OUTCOMES AFTER HYDROPHILIC COATED INFLATABLE PENILE PROSTHESIS IMPLANTS: 11 YEARS OF FOLLOW-UP
    Serefoglu, Ege Can
    Mandava, Sree Harsha
    Gokce, Ahmet
    Hellstrom, Wayne J. G.
    JOURNAL OF UROLOGY, 2012, 187 (04): : E560 - E561
  • [22] MENTOR INFLATABLE PENILE PROSTHESIS - A RELIABLE MECHANICAL DEVICE
    HACKLER, RH
    UROLOGY, 1986, 28 (06) : 489 - 491
  • [23] LONG TERM FOLLOW-UP OF INFLATABLE PENILE PROSTHESIS BY SINGLE SURGEON
    Choi, H. K.
    Choi, H. M.
    Kim, D. S.
    JOURNAL OF SEXUAL MEDICINE, 2010, 7 : 190 - 191
  • [24] Long-term mechanical reliability of AMS 700CX™/CXM inflatable penile prosthesis -: Comment
    Kabalin, John N.
    JOURNAL OF UROLOGY, 2006, 176 (06): : 2601 - 2601
  • [25] Re: Long-Term Infection Outcomes After Original Antibiotic Impregnated Inflatable Penile Prosthesis Implants: Up to 7.7 Years of Followup
    Serefoglu, Ege Can
    Mandava, Sree Harsha
    Hellstrom, Wayne J. G.
    JOURNAL OF UROLOGY, 2012, 187 (05): : 1936 - 1937
  • [26] INFLATABLE PENILE PROSTHESIS IMPLANTATION IN MEN UNDER 30: LONG-TERM OUTCOMES REGARDING PATIENT SATISFACTION
    Gross, M.
    Munarriz, R.
    JOURNAL OF SEXUAL MEDICINE, 2015, 12 : 138 - 138
  • [27] Penile prosthesis: Long-term follow up
    Mansi, MK
    SAUDI MEDICAL JOURNAL, 1996, 17 (03) : 365 - 369
  • [28] Long-Term Survival Rates of Inflatable Penile Prostheses: Systematic Review and Meta-Analysis
    Miller, Larry E.
    Khera, Mohit
    Bhattacharyya, Samir
    Patel, Mital
    Nitschelm, Krista
    Burnett, Arthur L.
    UROLOGY, 2022, 166 : 6 - 10
  • [29] INFLATABLE PENILE PROSTHESIS - EFFECT OF DEVICE MODIFICATION ON FUNCTIONAL LONGEVITY
    WOODWORTH, BE
    CARSON, CC
    WEBSTER, GD
    UROLOGY, 1991, 38 (06) : 533 - 536
  • [30] INFLATABLE PENILE PROSTHESIS - EFFECT OF DEVICE MODIFICATION ON FUNCTIONAL LONGEVITY
    WOODWORTH, BE
    CARSON, CC
    WEBSTER, GD
    JOURNAL OF UROLOGY, 1987, 137 (04): : A232 - A232