Excellent long-term device survival of inflatable penile prosthesis over 27 years

被引:0
|
作者
Moncada, Ignacio [1 ]
Krishnappa, Pramod [1 ,2 ]
Martinez-Salamanca, Juan Ignacio [3 ,4 ]
Palma-Hendges, Luiz Pedro [3 ]
Gonzalez-Garcia, Francisco Javier [3 ]
Hernandez-Fernandez, Carlos [5 ]
Lledo-Garcia, Enrique [5 ]
机构
[1] La Zarzuela Univ Hosp, Dept Urol & Robot Surg, Madrid 28023, Spain
[2] NU Hosp, Dept Urol & Robot Surg, Androl Div, AndroNeo,Orchidz Hlth, Bengaluru 560010, Karnataka, India
[3] Francisco Vitoria Univ, Lyx Inst Urol, Madrid 28006, Spain
[4] Puerta De Hierro Majadahonda Univ Hosp, Dept Urol, Madrid 28222, Spain
[5] Univ Complutense Madrid, Gregorio Maranon Univ Gen Hosp, Dept Urol, Madrid 28007, Spain
来源
关键词
device survival; erectile dysfunction; infection; mechanical failure; penile prosthesis; ERECTILE DYSFUNCTION; INFECTION; IMPLANTATION; OUTCOMES; INHIBITORS; EFFICACY; RISK; MEN; AUA;
D O I
10.4103/aja2024112
中图分类号
R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
摘要
The study aimed to assess the long-term device survival of a 3-piece inflatable penile prosthesis (PP) in patients with erectile dysfunction (ED). This retrospective observational longitudinal study involved patients with drug-refractory ED who underwent primary 3-piece inflatable PP implantation at a single center from 1992 to 2019. The outcomes included complications of various inflatable PP models, and Kaplan-Meier analysis was used to estimate the probability of PP survival. Of the total 426 patients, 140 (32.9%) were implanted in the period of 1992-2000, 128 (30.0%) in the period of 2001-2008, and 158 (37.1%) in the period of 2009-2019. The PP used in the study included AMS 700 CX (62.0%, n = 264), AMS 700 CXR (7.7%, n = 33), AMS Ultrex Plus (10.3%, n = 44), and Alpha I (20.0%, n = 85). The overall complication rate was 28.2% (120/426), and the majority happened after 6 months. The causes of device removal included mechanical failure (11.0%, n = 47), infection (3.9%, n = 17), cylinder extrusion (6.3%, n = 27), and unspecified (0.2%, n = 1). Of the total mechanical failures (n = 47), 18 (38.3%) occurred in the cylinders, 10 (21.3%) occurred in the pump, 7 (14.9%) occurred in the reservoir, 6 (12.8%) occurred in the connections, and 6 (12.8%) were nonspecific. Global average survival rates of the PP at 1 year, 5 years, 10 years, and 15 years were 96.2%, 86.7%, 77.5%, and 58.7%, respectively. The 3-piece inflatable PP has an excellent device survival rate at 5 years and 10 years.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Long-term mechanical reliability of multicomponent inflatable penile prosthesis: Comparison of device survival
    Dubocq, F
    Tefilli, MV
    Gheiler, EL
    Li, HK
    Dhabuwala, CB
    UROLOGY, 1998, 52 (02) : 277 - 281
  • [2] LONG-TERM EVALUATION OF THE INFLATABLE PENILE PROSTHESIS
    JOSEPH, DB
    BRUSKEWITZ, RC
    BENSON, RC
    JOURNAL OF UROLOGY, 1984, 131 (04): : 670 - 673
  • [3] Long-term survival and patient satisfaction with inflatable penile prosthesis for the treatment of erectile dysfunction
    Ji, Yoon Seob
    Ko, Young Hwii
    Song, Phil Hyun
    Moon, Ki Hak
    KOREAN JOURNAL OF UROLOGY, 2015, 56 (06) : 461 - 465
  • [4] LONG-TERM OUTCOMES OF INFLATABLE PENILE PROSTHESIS IN A VA PRACTICE
    Sax-Bolder, A.
    Van der Voort, G.
    Makedon, A.
    Shahinyan, G.
    Morrison, J.
    Lloyd, G.
    JOURNAL OF SEXUAL MEDICINE, 2023, 20
  • [5] LONG-TERM FOLLOW-UP IN PATIENTS WITH AN INFLATABLE PENILE PROSTHESIS
    FALLON, B
    ROSENBERG, S
    CULP, DA
    JOURNAL OF UROLOGY, 1984, 132 (02): : 270 - 271
  • [6] Survival and associated factors with long-term survival of penile prosthesis
    Bellaiche, J.
    Serrano, A. Gonzalez
    Larre, S.
    PROGRES EN UROLOGIE, 2021, 31 (06): : 374 - 380
  • [7] Long-term followup of treatment for Peyronie's disease: Modeling the penis over an inflatable penile prosthesis
    Wilson, SK
    Cleves, MA
    Delk, JR
    JOURNAL OF UROLOGY, 2001, 165 (03): : 825 - 829
  • [8] COMBINED PLACEMENT OF ARTIFICIAL URINARY SPHINCTER AND INFLATABLE PENILE PROSTHESIS DOES NOT INCREASE RISK OF PERIOPERATIVE COMPLICATIONS OR IMPACT LONG-TERM DEVICE SURVIVAL
    Boysen, William
    Cohen, Andrew
    Kuchta, Kristine
    Milose, Jaclyn
    JOURNAL OF UROLOGY, 2018, 199 (04): : E799 - E799
  • [9] Combined Placement of Artificial Urinary Sphincter and Inflatable Penile Prosthesis Does Not Increase Risk of Perioperative Complications or Impact Long-term Device Survival
    Boysen, William R.
    Cohen, Andrew J.
    Kuchta, Kristine
    Park, Sangtae
    Milose, Jaclyn
    UROLOGY, 2019, 124 : 264 - 270
  • [10] Long-term mechanical reliability of AMS 700 CX/CXM inflatable penile prosthesis
    Dhar, N
    Angermeier, KW
    Montague, D
    JOURNAL OF UROLOGY, 2006, 175 (04): : 423 - 423