Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research

被引:0
|
作者
Nang, Vo Sy Quyen [1 ,2 ,3 ]
Hieu, Pham Trung [3 ]
Nam, Vu Tu [3 ]
Dung, Tran Trung [2 ,3 ]
Toan, Duong Dinh [1 ]
机构
[1] Hanoi Med Univ, Hanoi, Vietnam
[2] Vinmec Healthcare Syst, Ctr Orthopaed & Sport Med, Hanoi, Vietnam
[3] VinUniversity, 3D Technol Med Ctr, Hanoi, Vietnam
关键词
3D printing; Total knee arthroplasty; TKA; In-hospital 3D printing; Patient-specific instrumentation; PSI; ROTATIONAL ALIGNMENT; TIBIAL COMPONENT; PAIN;
D O I
10.1016/j.jor.2024.10.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient-specific instruments (PSIs) were reported to improve implant position and rotation accuracy in total knee arthroplasty (TKA), among other benefits. Most PSIs used in TKA were commercial products from implant manufacturers, which could be time-consuming and could potentially affect accuracy as they relied on engineer's decision. This study aimed to present the radiological outcomes of PSI produced by the 3D printing facility at our hospital, with direct involvement of the surgeon in its design. Methods: This prospective study enrolled 45 patients who underwent mechanically aligned TKA. Preoperative whole-limb 3D-CT scans were obtained to create the sizing plan. The surgeon identified the position of the cut plane and guide pin locations on software, which were then forwarded to engineers for further processing. Subsequently, the PSI was fabricated using in-hospital 3D resin printers. During surgery, after removing all remaining cartilage, the PSI was utilized on the bone surfaces to assist surgeons in drilling pinhole positions for the manufacturer's cutting instruments. Post-surgery, CT scans were acquired and overlaid onto the 3D model of the implant to compare to the plan. Results: On average, it took three days to prepare for the surgery using PSI. 100 % of patients had implant sizes that matched the preconception template. The mean postoperative hip-knee angle was 178.1 degrees f 1.34 degrees. The mean femoral component rotation angle relative to the surgical transepicondylar axis (sTEA) and the mean rotation mismatch between the femur and tibial component were 0.99 degrees f 0.84 degrees and 0.91 degrees f 1.61 degrees, respectively. Conclusions: Preliminary radiological results demonstrated that in-hospital PSI was a useful technique for improving the accuracy of implant positioning in TKA, especially in controlling the rotational alignment.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [41] Patient-Specific Instrumentation Accuracy Evaluated with 3D Virtual Models
    Leon-Munoz, Vicente J.
    Parrinello, Andrea
    Manca, Silvio
    Galloni, Gianluca
    Lopez-Lopez, Mirian
    Martinez-Martinez, Francisco
    Santonja-Medina, Fernando
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (07)
  • [42] Functional Outcomes and Accuracy of Patient-Specific Instruments for Total Knee Arthroplasty
    Stone, Andrea H.
    Sibia, Udai S.
    MacDonald, James H.
    SURGICAL INNOVATION, 2018, 25 (05) : 470 - 475
  • [43] The Accuracy of Acetabular Cup Positioning Using Patient-Specific 3D Orientation Guidance in Total Hip Arthroplasty
    McMahon, Stephen J.
    Christmas, Maxim U. S., I
    McMahon, Jack
    Pierrepont, Jim
    McMahon, Ryan
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 36
  • [44] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Chen, Jerry Yongqiang
    Yeo, Seng Jin
    Yew, Andy Khye Soon
    Tay, Darren Keng Jin
    Chia, Shi-Lu
    Lo, Ngai Nung
    Chin, Pak Lin
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) : 630 - 635
  • [45] Patient-Specific Instrumentation in Total Knee Arthroplasty Provides No Improvement in Component Alignment
    Stronach, Benjamin M.
    Pelt, Christopher E.
    Erickson, Jill A.
    Peters, Christopher L.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09): : 1705 - 1708
  • [46] The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty
    Jerry Yongqiang Chen
    Seng Jin Yeo
    Andy Khye Soon Yew
    Darren Keng Jin Tay
    Shi-Lu Chia
    Ngai Nung Lo
    Pak Lin Chin
    Knee Surgery, Sports Traumatology, Arthroscopy, 2014, 22 : 630 - 635
  • [47] Reducing Blood Loss in Bilateral Total Knee Arthroplasty with Patient-Specific Instrumentation
    Rathod, Parthiv A.
    Deshmukh, Ajit J.
    Cushner, Fred D.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2015, 46 (03) : 343 - +
  • [48] Preoperative corrections are required for planning of patient-specific instrumentation in total knee arthroplasty
    Okada, Yohei
    Teramoto, Atsushi
    Suzuki, Tomoyuki
    Kii, Yuichiro
    Watanabe, Kota
    Yamashita, Toshihiko
    KNEE, 2017, 24 (06): : 1492 - 1497
  • [49] Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation
    Sébastien Parratte
    Guillaume Blanc
    Thomas Boussemart
    Matthieu Ollivier
    Thomas Le Corroller
    Jean-Noël Argenson
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2213 - 2219
  • [50] Patient-Specific Instrumentation Affects Perioperative Blood Loss in Total Knee Arthroplasty
    Cucchi, Davide
    Menon, Alessandra
    Zanini, Beatrice
    Compagnoni, Riccardo
    Ferrua, Paolo
    Randelli, Pietro
    JOURNAL OF KNEE SURGERY, 2019, 32 (06) : 483 - 489