Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research

被引:0
|
作者
Nang, Vo Sy Quyen [1 ,2 ,3 ]
Hieu, Pham Trung [3 ]
Nam, Vu Tu [3 ]
Dung, Tran Trung [2 ,3 ]
Toan, Duong Dinh [1 ]
机构
[1] Hanoi Med Univ, Hanoi, Vietnam
[2] Vinmec Healthcare Syst, Ctr Orthopaed & Sport Med, Hanoi, Vietnam
[3] VinUniversity, 3D Technol Med Ctr, Hanoi, Vietnam
关键词
3D printing; Total knee arthroplasty; TKA; In-hospital 3D printing; Patient-specific instrumentation; PSI; ROTATIONAL ALIGNMENT; TIBIAL COMPONENT; PAIN;
D O I
10.1016/j.jor.2024.10.032
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patient-specific instruments (PSIs) were reported to improve implant position and rotation accuracy in total knee arthroplasty (TKA), among other benefits. Most PSIs used in TKA were commercial products from implant manufacturers, which could be time-consuming and could potentially affect accuracy as they relied on engineer's decision. This study aimed to present the radiological outcomes of PSI produced by the 3D printing facility at our hospital, with direct involvement of the surgeon in its design. Methods: This prospective study enrolled 45 patients who underwent mechanically aligned TKA. Preoperative whole-limb 3D-CT scans were obtained to create the sizing plan. The surgeon identified the position of the cut plane and guide pin locations on software, which were then forwarded to engineers for further processing. Subsequently, the PSI was fabricated using in-hospital 3D resin printers. During surgery, after removing all remaining cartilage, the PSI was utilized on the bone surfaces to assist surgeons in drilling pinhole positions for the manufacturer's cutting instruments. Post-surgery, CT scans were acquired and overlaid onto the 3D model of the implant to compare to the plan. Results: On average, it took three days to prepare for the surgery using PSI. 100 % of patients had implant sizes that matched the preconception template. The mean postoperative hip-knee angle was 178.1 degrees f 1.34 degrees. The mean femoral component rotation angle relative to the surgical transepicondylar axis (sTEA) and the mean rotation mismatch between the femur and tibial component were 0.99 degrees f 0.84 degrees and 0.91 degrees f 1.61 degrees, respectively. Conclusions: Preliminary radiological results demonstrated that in-hospital PSI was a useful technique for improving the accuracy of implant positioning in TKA, especially in controlling the rotational alignment.
引用
收藏
页码:70 / 74
页数:5
相关论文
共 50 条
  • [21] Total Knee Arthroplasty: Validating The Benefits Of Patient-Specific Instrumentation
    Moore, S.
    Linton, K. N.
    Martin, P.
    Headon, R. J.
    Bennett, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S74 - S75
  • [22] The application of 3D printing patient specific instrumentation model in total knee arthroplasty
    Zhou, Fengxin
    Xue, Feng
    Zhang, Shuquan
    SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2020, 27 (05) : 1217 - 1221
  • [23] Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty
    Lustig, Sebastien
    Scholes, Corey J.
    Oussedik, Sam I.
    Kinzel, Vera
    Coolican, Myles R. J.
    Parker, David A.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (03): : 469 - 473
  • [24] Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis
    Kizaki, Kazuha
    Shanmugaraj, Ajaykumar
    Yamashita, Fumiharu
    Simunovic, Nicole
    Duong, Andrew
    Khanna, Vickas
    Ayeni, Olufemi R.
    BMC MUSCULOSKELETAL DISORDERS, 2019, 20 (01)
  • [25] Total knee arthroplasty using patient-specific instrumentation for osteoarthritis of the knee: a meta-analysis
    Kazuha Kizaki
    Ajaykumar Shanmugaraj
    Fumiharu Yamashita
    Nicole Simunovic
    Andrew Duong
    Vickas Khanna
    Olufemi R. Ayeni
    BMC Musculoskeletal Disorders, 20
  • [26] An investigation of innovative 3D modelling procedures for patient-specific total knee arthroplasty
    Ghidotti A.
    Vitali A.
    Regazzoni D.
    Rizzi C.
    Computer-Aided Design and Applications, 2022, 19 (02): : 306 - 319
  • [27] Assessing the accuracy of patient-specific guides for total knee arthroplasty
    Jong-Keun Seon
    Hyeong-Won Park
    Seung-Hyun Yoo
    Eun-Kyoo Song
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 3678 - 3683
  • [28] A METHOD TO GENERATE 3D PATIENT-SPECIFIC TOTAL KNEE ARTHROPLASTY TIBIA MODELS
    Gothard, Andrew T.
    Anton, Steven R.
    PROCEEDINGS OF ASME 2022 CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS, SMASIS2022, 2022,
  • [29] Assessing the accuracy of patient-specific guides for total knee arthroplasty
    Seon, Jong-Keun
    Park, Hyeong-Won
    Yoo, Seung-Hyun
    Song, Eun-Kyoo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2016, 24 (11) : 3678 - 3683
  • [30] Patient-specific instrumentation in total knee arthroplasty: a review of the current literature
    Schoenthaler, Wolfgang
    Dauwe, Jan
    Holzer, Lukas A.
    ACTA ORTHOPAEDICA BELGICA, 2023, 89 (02): : 299 - 306