Does Root Canal Shaping Effect the Accuracy of Electronic Apex Locators in Curved and Straight Root Canals?

被引:0
|
作者
Tekinarslan, Dide [1 ]
Erkal, Damla [1 ]
Ercan, Esen [1 ]
Koc, Simay [1 ]
Er, Kursat [1 ]
机构
[1] Akdeniz Univ, Fac Dent, Dept Endodont, Antalya, Turkiye
来源
关键词
Working length; root canal preparation; curvature; straight canal; WORKING LENGTH; ABILITY; INSTRUMENTATION; FREQUENCY;
D O I
10.33808/clinexphealthsci.1354100
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To assess the influence of root canal preparation (RCP) on the precision of electronic apex locators (EALs) in both straight and curved root canals. Methods: The experimental setup included forty-two extracted human mandibular molars featuring both straight distal canals (0-10 degrees) and curved mesial root canals (30-50 degrees). Initial working length (AWL1) measurements were conducted under a stereomicroscope at X15 magnification prior to root canal preparation (RCP). Subsequently, electronic working length (EWL1) was determined using two different electronic apex locators (EALs) - Propex-Pixi and EndoRadar. RCP was carried out with ProTaper Ultimate F1, F2 files in mesial canals, and F1, F2, F3 files in distal straight root canals. The RCP procedure involved the implementation of a standard irrigation protocol along with the use of a sonic device for activation. Following RCP, measurements were repeated under a stereomicroscope and documented as AWL2. EWL measurements were also repeated and recorded as EWL2 after the preparation. The variation was calculated by subtracting AWL from EWL for each tooth (EWL1-AWL1 and EWL2-AWL2). Statistical analysis employed Paired Sample t-test and Wilcoxon tests. Results: There was no statistically significant difference observed in the accuracy of Propex-Pixi and EndoRadar Pro before and after root canal preparation for both straight and curved canals. Conclusion: Root canal preparation did not alter the accuracy of the electronic apex locators (EALs) used in this study, whether applied to curved or straight root canals.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 50 条
  • [31] In vitro evaluation of the accuracy of electronic apex locators and cone-beam CT in the detection of oblique root fractures
    Koc, Simay
    Harorli, Hatice
    Kustarci, Alper
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (07) : 509 - 514
  • [32] THE EFFECT OF ROOT-CANAL PREPARATION ON THE SHAPE OF THE CURVED ROOT-CANAL
    LIM, KC
    WEBBER, J
    INTERNATIONAL ENDODONTIC JOURNAL, 1985, 18 (04) : 233 - 239
  • [33] An ex vivo comparison of root canal length determination by three electronic apex locators at positions short of the apical foramen
    de Vasconcelos, Bruno Carvalho
    do Vale, Taina Macedo
    Teixeira de Menezes, Antonio Sergio
    Pinheiro-Junior, Elilton Cavalcante
    Vivacqua-Gomes, Nilton
    Bernardes, Ricardo Affonso
    Hungaro Duarte, Marco Antonio
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (02): : E57 - E61
  • [34] In Vivo Evaluation of 3 Electronic Apex Locators: Root ZX Mini, Apex ID, and Propex Pixi
    Serna-Pena, Gabriela
    Gomes-Azevedo, Susana
    Flores-Trevino, Jorge
    Madla-Cruz, Elizabeth
    Rodriguez-Delgado, Idalia
    Martinez-Gonzalez, Gustavo
    JOURNAL OF ENDODONTICS, 2020, 46 (02) : 158 - 161
  • [35] Comparative evaluation of the accuracy of electronic apex locators and cone-beam computed tomography in detection of root canal perforation and working length during endodontic retreatment
    Koc, Simay
    Harorli, Hatice
    Kustarci, Alper
    BMC ORAL HEALTH, 2024, 24 (01):
  • [36] Comparative evaluation of the preparation efficacies of HERO Shaper and Nitiflex root canal instruments in curved root canals
    Kaptan, F
    Sert, S
    Kayahan, B
    Haznedaroglu, F
    Tanalp, J
    Bayirli, G
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2005, 100 (05): : 636 - 642
  • [37] THE EFFECT OF ENDOSONIC INSTRUMENTATION IN SIMULATED CURVED ROOT CANALS
    KIELT, LW
    MONTGOMERY, S
    JOURNAL OF ENDODONTICS, 1987, 13 (05) : 215 - 219
  • [38] The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures
    Goldberg, Fernando
    Frajlich, Santiago
    Kuttler, Sergio
    Manzur, Emilio
    Briseno-Marroquin, Benjamin
    JOURNAL OF ENDODONTICS, 2008, 34 (12) : 1497 - 1499
  • [39] The effect of different needle-insertion depths on the accuracy of the Root ZX II and Root ZX mini apex locators in the presence of various irrigants
    Raoof, Maryam
    Rad, Maryam
    Mansoori, Mohammad Rasoul
    Askarifard, Sara
    Nourzadeh, Mahdieh
    Shokouhinejad, Noushin
    Samani-Poor, Siamak
    JOURNAL OF ORAL HEALTH AND ORAL EPIDEMIOLOGY, 2013, 2 (02): : 81 - 88
  • [40] In vivo evaluation of the iPex and Root ZX electronic apex locators using various irrigants
    Duran-Sindreu, F.
    Gomes, S.
    Stoeber, E.
    Mercade, M.
    Jane, L.
    Roig, M.
    INTERNATIONAL ENDODONTIC JOURNAL, 2013, 46 (08) : 769 - 774