Does Root Canal Shaping Effect the Accuracy of Electronic Apex Locators in Curved and Straight Root Canals?

被引:0
|
作者
Tekinarslan, Dide [1 ]
Erkal, Damla [1 ]
Ercan, Esen [1 ]
Koc, Simay [1 ]
Er, Kursat [1 ]
机构
[1] Akdeniz Univ, Fac Dent, Dept Endodont, Antalya, Turkiye
来源
关键词
Working length; root canal preparation; curvature; straight canal; WORKING LENGTH; ABILITY; INSTRUMENTATION; FREQUENCY;
D O I
10.33808/clinexphealthsci.1354100
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To assess the influence of root canal preparation (RCP) on the precision of electronic apex locators (EALs) in both straight and curved root canals. Methods: The experimental setup included forty-two extracted human mandibular molars featuring both straight distal canals (0-10 degrees) and curved mesial root canals (30-50 degrees). Initial working length (AWL1) measurements were conducted under a stereomicroscope at X15 magnification prior to root canal preparation (RCP). Subsequently, electronic working length (EWL1) was determined using two different electronic apex locators (EALs) - Propex-Pixi and EndoRadar. RCP was carried out with ProTaper Ultimate F1, F2 files in mesial canals, and F1, F2, F3 files in distal straight root canals. The RCP procedure involved the implementation of a standard irrigation protocol along with the use of a sonic device for activation. Following RCP, measurements were repeated under a stereomicroscope and documented as AWL2. EWL measurements were also repeated and recorded as EWL2 after the preparation. The variation was calculated by subtracting AWL from EWL for each tooth (EWL1-AWL1 and EWL2-AWL2). Statistical analysis employed Paired Sample t-test and Wilcoxon tests. Results: There was no statistically significant difference observed in the accuracy of Propex-Pixi and EndoRadar Pro before and after root canal preparation for both straight and curved canals. Conclusion: Root canal preparation did not alter the accuracy of the electronic apex locators (EALs) used in this study, whether applied to curved or straight root canals.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 50 条
  • [11] Canal shaping of different single-file systems in curved root canals
    D'Amario, Maurizio
    De Angelis, Francesco
    Mancino, Maddalena
    Frascaria, Massimo
    Capogreco, Mario
    D'Arcangelo, Camillo
    JOURNAL OF DENTAL SCIENCES, 2017, 12 (04) : 328 - 332
  • [12] Ex vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth
    Leonardo, M. R.
    Silva, L. A. B.
    Nelson-Filho, P.
    Silva, R. A. B.
    Raffaini, M. S. G. G.
    INTERNATIONAL ENDODONTIC JOURNAL, 2008, 41 (04) : 317 - 321
  • [13] Determination of location of root perforations by electronic apex locators
    Fuss, Z
    Assooline, LS
    Kaufman, AY
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 82 (03): : 324 - 329
  • [14] Effect of preflaring on Root ZX apex locators
    Ibarrola, JL
    Chapman, BL
    Howard, JH
    Knowles, KI
    Ludlow, MO
    JOURNAL OF ENDODONTICS, 1999, 25 (09) : 625 - 626
  • [15] The Effect of Different Irrigation Solutions on the Accuracy of Two Electronic Apex Locators in Locating Artificial Root Perforations
    Aydin, Zeliha Ugur
    Altunbas, Demet
    Meseci, Busra
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2020, 21 (02): : 134 - 139
  • [16] Accuracy and Repeatability of 3 Apex Locators in Locating Root Canal Perforations: An Ex Vivo Study
    Cunha D'Assuncao, Fabio Luiz
    Nascimento Sousa, Julio Cezar
    Amaro Felinto, Kayo Cesar
    de Medeiros, Thiago Clistines
    Leite, Diego Tavares
    de Lucena, Raissa Bezerra
    Lima, Joab de Oliveira
    JOURNAL OF ENDODONTICS, 2014, 40 (08) : 1241 - 1244
  • [17] A Micro-computed Tomographic Evaluation of the Accuracy of 3 Electronic Apex Locators in Curved Canals of Mandibular Molars
    Piasecki, Lucila
    dos Reis, Paulo Jose
    Jussiani, Eduardo Inocente
    Andrello, Avacir Casanova
    JOURNAL OF ENDODONTICS, 2018, 44 (12) : 1872 - 1877
  • [18] The Influence of Various Irrigants on the Accuracy of 2 Electronic Apex Locators in Locating Simulated Root Perforations
    Altunbas, Demet
    Kustarci, Alper
    Toyoglu, Mustafa
    JOURNAL OF ENDODONTICS, 2017, 43 (03) : 439 - 442
  • [19] Ex Vivo Evaluation of the Accuracy of Electronic Foramen Locators in Root Canals with an Obstructed Apical Foramen
    de Vasconcelos, Bruno Carvalho
    Verissimo Chaves, Rebeca Dibe
    Vivacqua-Gomes, Nilton
    de Miranda Candeiro, George Taccio
    Bernardes, Ricardo Affonso
    Vivan, Rodrigi Ricci
    Hungaro Duarte, Marco Antonio
    JOURNAL OF ENDODONTICS, 2015, 41 (09) : 1551 - 1554
  • [20] Transportation and shaping ability of 3 canal anatomy-friendly systems in curved root canals
    Ozad, Merve Babacan
    Cikman, Ahter Sanal
    Koese, Taha Emre
    Aricioglu, Banu
    ANNALS OF CLINICAL AND ANALYTICAL MEDICINE, 2023, 14 (07): : 595 - 599