Does Root Canal Shaping Effect the Accuracy of Electronic Apex Locators in Curved and Straight Root Canals?

被引:0
|
作者
Tekinarslan, Dide [1 ]
Erkal, Damla [1 ]
Ercan, Esen [1 ]
Koc, Simay [1 ]
Er, Kursat [1 ]
机构
[1] Akdeniz Univ, Fac Dent, Dept Endodont, Antalya, Turkiye
来源
关键词
Working length; root canal preparation; curvature; straight canal; WORKING LENGTH; ABILITY; INSTRUMENTATION; FREQUENCY;
D O I
10.33808/clinexphealthsci.1354100
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objective: To assess the influence of root canal preparation (RCP) on the precision of electronic apex locators (EALs) in both straight and curved root canals. Methods: The experimental setup included forty-two extracted human mandibular molars featuring both straight distal canals (0-10 degrees) and curved mesial root canals (30-50 degrees). Initial working length (AWL1) measurements were conducted under a stereomicroscope at X15 magnification prior to root canal preparation (RCP). Subsequently, electronic working length (EWL1) was determined using two different electronic apex locators (EALs) - Propex-Pixi and EndoRadar. RCP was carried out with ProTaper Ultimate F1, F2 files in mesial canals, and F1, F2, F3 files in distal straight root canals. The RCP procedure involved the implementation of a standard irrigation protocol along with the use of a sonic device for activation. Following RCP, measurements were repeated under a stereomicroscope and documented as AWL2. EWL measurements were also repeated and recorded as EWL2 after the preparation. The variation was calculated by subtracting AWL from EWL for each tooth (EWL1-AWL1 and EWL2-AWL2). Statistical analysis employed Paired Sample t-test and Wilcoxon tests. Results: There was no statistically significant difference observed in the accuracy of Propex-Pixi and EndoRadar Pro before and after root canal preparation for both straight and curved canals. Conclusion: Root canal preparation did not alter the accuracy of the electronic apex locators (EALs) used in this study, whether applied to curved or straight root canals.
引用
收藏
页码:727 / 732
页数:6
相关论文
共 50 条
  • [1] Effects of different irrigation solutions on the accuracy of electronic apex locators in curved and straight root canals
    Tekinarslan, Dide
    Erkal, Damla
    Pehlivan, Burcu
    Unal, Elif
    Kayar, Goknur
    Koc, Simay
    Er, Kursat
    GIORNALE ITALIANO DI ENDODONZIA, 2023, 37 (01): : 54 - 61
  • [2] COMPARISON OF CANAL PREPARATIONS IN STRAIGHT AND CURVED ROOT CANALS
    SCHNEIDER, SW
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1971, 32 (02): : 271 - +
  • [3] Modern electronic apex locators are reliable for determining root canal working length: How accurate are electronic apex locators in the determination of root canal length?
    Balto K.A.
    Evidence-Based Dentistry, 2006, 7 (2) : 31 - 32
  • [4] Coronal preflaring's influence on the accuracy of root canal length determination by electronic apex locators
    Batista, Larissa C. Novaes
    Janini, Ana Cristina Padilha
    Marciano, Marina A.
    Guimaraes, Tatiany G. F. Araujo
    Guimaraes, Bruno Martini
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2024, 65 (03): : 115 - 120
  • [5] The effect of various canal contents on the accuracy of two electronic apex locators in detecting different size of root perforations
    Cankaya, Tulin Dogan
    Aydin, Zeliha Ugur
    Altunbas, Demet
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2021, 11 (02): : 258 - 262
  • [6] In vitro evaluation of the accuracy of Root ZX series electronic apex locators
    Duh, Bor-Ren
    JOURNAL OF DENTAL SCIENCES, 2009, 4 (02) : 75 - 80
  • [7] Accuracy of electronic apex locators to detect root canal perforations with inserted metallic posts: an ex vivo study
    Marroquin, Benjamin Briseno
    Fernandez, Claudia Cortazar
    Schmidtmann, Irene
    Willershausen, Brita
    Goldberg, Fernando
    HEAD & FACE MEDICINE, 2014, 10 : 57
  • [8] Accuracy of electronic apex locators to detect root canal perforations with inserted metallic posts: an ex vivo study
    Benjamín Briseño Marroquín
    Claudia Cortazar Fernández
    Irene Schmidtmann
    Brita Willershausen
    Fernando Goldberg
    Head & Face Medicine, 10
  • [9] Accuracy of different electronic apex locators in determination of minimum Root perforation diameter
    Koc, Simay
    Kustarci, Alper
    Er, Kursat
    AUSTRALIAN ENDODONTIC JOURNAL, 2023, 49 : 179 - 186
  • [10] Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An In Vitro Comparative Study
    Yahya, Eman M.
    Alchalabi, Ashraf S.
    Alkhalidi, Emad Farhan
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2024, 14 (03): : 211 - 217