Non-contrast free-breathing liver perfusion imaging using velocity selective ASL combined with prospective motion compensation

被引:0
|
作者
Zhang, Ke [1 ,2 ,3 ,4 ]
Triphan, Simon M. F. [1 ,2 ,3 ]
Wielpuetz, Mark O. [1 ,2 ,3 ]
Ziener, Christian H. [4 ]
Ladd, Mark E. [5 ,6 ,7 ]
Schlemmer, Heinz-Peter [4 ]
Kauczor, Hans-Ulrich [1 ,2 ,3 ]
Sedlaczek, Oliver [1 ,3 ,4 ]
Kurz, Felix T. [4 ,8 ]
机构
[1] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol, Heidelberg, Germany
[2] German Ctr Lung Res DZL, Translat Lung Res Ctr TLRC, Heidelberg, Germany
[3] Heidelberg Univ Hosp, Dept Diagnost & Intervent Radiol Nucl Med, Thoraxklin, Heidelberg, Germany
[4] German Canc Res Ctr, Div Radiol, D-69120 Heidelberg, Germany
[5] German Canc Res Ctr, Div Med Phys Radiol, Heidelberg, Germany
[6] Heidelberg Univ, Fac Phys & Astron, Heidelberg, Germany
[7] Heidelberg Univ, Fac Med, Heidelberg, Germany
[8] Geneva Univ Hosp, Div Neuroradiol, Geneva, Switzerland
来源
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK | 2025年 / 35卷 / 01期
关键词
Velocity selective arterial spin labeling; Liver perfusion; Prospective motion compensation; Navigator-based slice tracking; BLOOD-FLOW; ARTERIAL; QUANTIFICATION;
D O I
10.1016/j.zemedi.2024.06.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To apply velocity selective arterial spin labeling (VSASL) combined with a navigator-based (NAV) prospective motion compensation method for a free-breathing liver perfusion measurement without contrast agent. Methods: Sinc-modulated Velocity Selective Inversion (sinc-VSI) pulses were applied as labeling and control pulses. In order to account for respiratory motion, a navigator was employed in the form of a single gradient-echo projection readout, located at the diaphragm along the inferior-superior direction. Prior to each transverse imaging slice of the spin-echo EPI based readouts, navigator and fat suppression were incorporated. Motion data was obtained from the navigator and transmitted back to the sequence, allowing real-time adjustments to slice positioning. The sinc-VSI without velocity-selective gradients during the control condition but with velocity-selective gradients along all three directions during labeling was chosen for the VSASL. The VSASL was compared with pseudo-continuous ASL (pCASL) methods, which selectively tagged the moving spins using a tagging plane placed at the portal vein and hepatic artery. Results: The motion caused by respiratory activity was effectively computed using the navigator signal. The coefficients of variation (CoV) of average liver voxel in NAV were significantly decreased when compared to breath-hold (BH), with an average reduction of 29.4 +/- 18.44% for control images, and 29.89 +/- 20.83% for label images (p < 0.001). The resulting maps of normalized ASL signal (normalized to M-0) showed significantly higher perfusion weightings in the NAV-compensated VSASL, when compared to the NAV-compensated pCASL techniques. Conclusions: This study demonstrates the feasibility of using a navigator-based prospective motion compensation technique in conjunction with VSASL for the measurement of liver perfusion without the use of contrast agents while allowing for free-breathing.
引用
收藏
页码:87 / 97
页数:11
相关论文
共 50 条
  • [31] Motion corrected free-breathing Delayed-enhancement imaging of myocardial infarction using nonrigid registration
    Ledesma-Carbayo, Maria J.
    Kellman, Peter
    Arai, Andrew E.
    McVeigh, Elliot R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (01) : 184 - 190
  • [32] Improved Workflow for Quantification of Right Ventricular Volumes Using Free-Breathing Motion Corrected Cine Imaging
    Anthony Merlocco
    Laura Olivieri
    Peter Kellman
    Hui Xue
    Russell Cross
    Pediatric Cardiology, 2019, 40 : 79 - 88
  • [33] Feasibility of free-breathing quantitative myocardial perfusion using multi-echo Dixon magnetic resonance imaging
    Scannell, Cian M.
    Correia, Teresa
    Villa, Adriana D. M.
    Schneider, Torben
    Lee, Jack
    Breeuwer, Marcel
    Chiribiri, Amedeo
    Henningsson, Markus
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [34] Feasibility of free-breathing quantitative myocardial perfusion using multi-echo Dixon magnetic resonance imaging
    Cian M. Scannell
    Teresa Correia
    Adriana D. M. Villa
    Torben Schneider
    Jack Lee
    Marcel Breeuwer
    Amedeo Chiribiri
    Markus Henningsson
    Scientific Reports, 10
  • [35] Free-breathing motion-informed locally low-rank quantitative 3D myocardial perfusion imaging
    Hoh, Tobias
    Vishnevskiy, Valery
    Polacin, Malgorzata
    Manka, Robert
    Fuetterer, Maximilian
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (04) : 1575 - 1591
  • [36] Motion Compensation for Free-Breathing Diffusion-Weighted Imaging (MoCo DWI) in Whole Body Integrated PET-MRI
    David, Christian
    Vahle, Thomas
    Grimm, Robert
    Kiefer, Berthold
    Bachert, Peter
    Kachelriess, Marc
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [37] Free-breathing multi-parametric SASHA (mSASHA) mapping provides reliable non-contrast myocardial characterization in a pediatric and adult congenital population
    Christopher, Adam B.
    Gurijala, Nyshidha
    Cross, Russell R.
    Olivieri, Laura J.
    Chow, Kelvin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2025, 41 (03): : 549 - 557
  • [38] Automatic motion compensation of free breathing acquired myocardial perfusion data by using independent component analysis
    Wollny, Gert
    Kellman, Peter
    Santos, Andres
    Ledesma-Carbayo, Maria J.
    MEDICAL IMAGE ANALYSIS, 2012, 16 (05) : 1015 - 1028
  • [39] Comprehensive Neonatal Cardiac, Feed and Wrap, Non-contrast, Non-sedated, Free-breathing Compressed Sensing 4D Flow MRI Assessment
    Panayiotou, Hannah R.
    Mills, Lily K.
    Broadbent, David A.
    Shelley, David
    Scheffczik, Jutta
    Olaru, Alexandra M.
    Jin, Ning
    Greenwood, John P.
    Michael, Helen
    Plein, Sven
    Bissell, Malenka M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2023, 57 (03) : 789 - 799
  • [40] Assessment of Pulmonary Perfusion With Breath-Hold and Free-Breathing Dynamic Contrast-Enhanced Magnetic Resonance Imaging Quantification and Reproducibility
    Ingrisch, Michael
    Maxien, Daniel
    Schwab, Felix
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    Dietrich, Olaf
    INVESTIGATIVE RADIOLOGY, 2014, 49 (06) : 382 - 389