Automated hallucination detection for synthetic CT images used in MR-only radiotherapy workflows

被引:0
|
作者
Parchur, Abdul K. [1 ]
Zarenia, Mohammad [1 ]
Gage, Colette [1 ]
Paulson, Eric S. [1 ]
Ahunbay, Ergun [1 ]
机构
[1] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2025年 / 70卷 / 05期
关键词
hallucinations; synthetic CT-sCT; MR-only radiation therapy;
D O I
10.1088/1361-6560/adb5eb
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Artificial intelligence (AI)-generated synthetic CT (sCT) images have become commercially available to provide electron densities and reference anatomies in MR-only radiotherapy workflows. However, hallucinations (false regions of bone or air) introduced in AI-generated sCT images may affect the accuracy of dose calculation and patient setup verification. We developed a tool to detect bone hallucinations and/or inaccuracies in AI-generated pelvic sCT images used in MR-only workflows. Approach. A deep learning auto segmentation (DLAS) model was trained to auto-segment bone on MR images. The model was implemented with a 3D SegResNet network architecture using the MONAI framework with a training dataset of 86 Dixon MR image sets paired with their corresponding ground truth contours derived from planning CT images deformed to the MR images. The model performance was then assessed on an independent testing dataset (n = 10). Main results. The DLAS model-based hallucination screener identified hallucinations in bone structures using daily MR images and accurately flagged these regions on sCT images. The sensitivity of the screener is adjustable based on the distance of discrepancies between bone regions derived from sCT to bone contours generated by the DLAS. The average specificity of the DLAS model was 0.78, 0.93 and 0.98 for distance parameters of 0.8, 1.0 and 1.2 cm, respectively. The screener identified false high-density hallucination regions in the abdomen of AI-generated sCT images for all testing patients, highlighting potential issues with the training data used for the AI sCT model. Significance. A hallucination screener for AI-generated pelvic sCT images was developed and implemented for routine clinical use. The screener serves as an important quality assurance tool for MR-only radiotherapy workflows. By identifying potential AI-generated errors, the hallucination screener may improve the safety and accuracy of sCT images used for dose calculation and image guidance.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] The rationale for MR-only treatment planning for external radiotherapy
    Jonsson, Joakim
    Nyholm, Tufve
    Soderkvist, Karin
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2019, 18 : 60 - 65
  • [42] MR-only prostate radiotherapy - how transferable are CT based image matching skills?
    Brooks, R.
    McCallum, H. M.
    Pilling, K.
    Pearson, R. A.
    Wyatt, J. J.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S1077 - S1077
  • [43] MR-only Procedures for Improved Overall Precision in Radiotherapy
    Karlsson, M.
    Nyholm, T.
    Karlsson, M. G.
    Zackrisson, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S656 - S656
  • [44] Structurally-constrained optical-flow-guided adversarial generation of synthetic CT for MR-only radiotherapy treatment planning
    Vajpayee, Rajat
    Agrawal, Vismay
    Krishnamurthi, Ganapathy
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [45] Dose evaluation of fast synthetic-CT generation using a generative adversarial network for general pelvis MR-only radiotherapy
    Maspero, Matteo
    Savenije, Mark H. F.
    Dinkla, Anna M.
    Seevinck, Peter R.
    Intven, Martijn P. W.
    Jurgenliemk-Schulz, Ina M.
    Kerkmeijer, Linda G. W.
    van den Berg, Cornelis A. T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (18):
  • [46] Validation of a Commercial Continuous Hounsfield Unit (HU) Pelvis Synthetic CT Platform for MR-Only Prostate Radiotherapy Treatment Planning
    Yu, V.
    Hunt, M.
    Cervino, L.
    Damato, A.
    Tyagi, N.
    MEDICAL PHYSICS, 2020, 47 (06) : E669 - E669
  • [47] Structurally-constrained optical-flow-guided adversarial generation of synthetic CT for MR-only radiotherapy treatment planning
    Rajat Vajpayee
    Vismay Agrawal
    Ganapathy Krishnamurthi
    Scientific Reports, 12
  • [48] Automated MR-Only RT for H&N cancer: synthetic CTs, autocontouring and automated treatment planning
    Petit, S.
    Kaushik, S.
    Rusko, L.
    Cozzini, C.
    Deak-Karancsi, B.
    Czipczer, V.
    Kolozsvari, B.
    Hideghety, K.
    Fronto, A.
    Maros, B.
    Kleijnen, J.
    Wyatt, J.
    McCallum, H.
    Verduijn, G.
    Wiesinger, F.
    Hernandez-Tamames, J.
    Capala, M.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S258 - S259
  • [49] MRI only prostate radiotherapy using synthetic CT images
    Persson, E.
    Nordstrom, F.
    Siversson, C.
    Ceberg, C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S72 - S72
  • [50] Investigation of 3D-Printed Phantoms for Synthetic CT Benchmarking in An MR-Only Workflow
    Kim, J.
    Myers, E.
    Forbes, M.
    Chetty, I.
    Glide-Hurst, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657