Automated hallucination detection for synthetic CT images used in MR-only radiotherapy workflows

被引:0
|
作者
Parchur, Abdul K. [1 ]
Zarenia, Mohammad [1 ]
Gage, Colette [1 ]
Paulson, Eric S. [1 ]
Ahunbay, Ergun [1 ]
机构
[1] Med Coll Wisconsin, Dept Radiat Oncol, Milwaukee, WI 53226 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2025年 / 70卷 / 05期
关键词
hallucinations; synthetic CT-sCT; MR-only radiation therapy;
D O I
10.1088/1361-6560/adb5eb
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Artificial intelligence (AI)-generated synthetic CT (sCT) images have become commercially available to provide electron densities and reference anatomies in MR-only radiotherapy workflows. However, hallucinations (false regions of bone or air) introduced in AI-generated sCT images may affect the accuracy of dose calculation and patient setup verification. We developed a tool to detect bone hallucinations and/or inaccuracies in AI-generated pelvic sCT images used in MR-only workflows. Approach. A deep learning auto segmentation (DLAS) model was trained to auto-segment bone on MR images. The model was implemented with a 3D SegResNet network architecture using the MONAI framework with a training dataset of 86 Dixon MR image sets paired with their corresponding ground truth contours derived from planning CT images deformed to the MR images. The model performance was then assessed on an independent testing dataset (n = 10). Main results. The DLAS model-based hallucination screener identified hallucinations in bone structures using daily MR images and accurately flagged these regions on sCT images. The sensitivity of the screener is adjustable based on the distance of discrepancies between bone regions derived from sCT to bone contours generated by the DLAS. The average specificity of the DLAS model was 0.78, 0.93 and 0.98 for distance parameters of 0.8, 1.0 and 1.2 cm, respectively. The screener identified false high-density hallucination regions in the abdomen of AI-generated sCT images for all testing patients, highlighting potential issues with the training data used for the AI sCT model. Significance. A hallucination screener for AI-generated pelvic sCT images was developed and implemented for routine clinical use. The screener serves as an important quality assurance tool for MR-only radiotherapy workflows. By identifying potential AI-generated errors, the hallucination screener may improve the safety and accuracy of sCT images used for dose calculation and image guidance.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Dosimetric Evaluation of Magnetic Resonance-Generated Synthetic CT for MR-Only Rectal Cancer Radiotherapy
    Wang, H.
    Du, K.
    Qu, J.
    Chandarana, H.
    Das, I.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [22] Synthetic CT reconstruction using a deep spatial pyramid convolutional framework for MR-only breast radiotherapy
    Olberg, Sven
    Zhang, Hao
    Kennedy, William R.
    Chun, Jaehee
    Rodriguez, Vivian
    Zoberi, Imran
    Thomas, Maria A.
    Kim, Jin Sung
    Mutic, Sasa
    Green, Olga L.
    Park, Justin C.
    MEDICAL PHYSICS, 2019, 46 (09) : 4135 - 4147
  • [23] MR-Based Synthetic-CT Generation Using Generative Adversarial Network for Head and Neck MR-Only Radiotherapy
    Qi, M.
    Li, Y.
    Wu, A.
    Guo, F.
    Jia, Q.
    Zhou, L.
    Song, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E112 - E112
  • [24] CycleSeg: Simultaneous synthetic CT generation and unsupervised segmentation for MR-only radiotherapy treatment planning of prostate cancer
    Luu, Huan Minh
    Yoo, Gyu Sang
    Park, Won
    Park, Sung-Hong
    MEDICAL PHYSICS, 2024, 51 (06) : 4365 - 4379
  • [25] MR-guided multi-atlas based synthetic CT for MR-only radiotherapy of head and neck cancer patients
    Farjam, R.
    Tyagi, N.
    Veeraraghavan, H.
    Apte, A.
    Zakian, K.
    Hunt, M.
    Deasy, J.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S71 - S72
  • [26] Two-ways validation of the feasibility of AI-based synthetic CT for MR-only brain radiotherapy
    Masitho, S.
    Szkitsak, J.
    Grigo, J.
    Putz, F.
    Fietkau, R.
    Bert, C.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S283 - S283
  • [27] Deep learning-based synthetic CT generation for paediatric brain MR-only photon and proton radiotherapy
    Maspero, Matteo
    Bentvelzen, Laura G.
    Savenije, Mark H. F.
    Guerreiro, Filipa
    Seravalli, Enrica
    Janssens, Geert O.
    van den Berg, Cornelis A. T.
    Philippens, Marielle E. P.
    RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 197 - 204
  • [28] A deep learning model to generate synthetic CT for prostate MR-only radiotherapy dose planning: a multicenter study
    Tahri, Safaa
    Texier, Blanche
    Nunes, Jean-Claude
    Hemon, Cedric
    Lekieffre, Pauline
    Collot, Emma
    Chourak, Hilda
    Le Guevelou, Jennifer
    Greer, Peter
    Dowling, Jason
    Acosta, Oscar
    Bessieres, Igor
    Marage, Louis
    Boue-Rafle, Adrien
    De Crevoisier, Renaud
    Lafond, Caroline
    Barateau, Anais
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [29] Generation of synthetic CT with 3D deep convolutional neural networks for brain MR-only radiotherapy
    Aouadi, S.
    Hammoud, R.
    Torfeh, T.
    Paloor, S.
    Al-hammadi, N.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1377 - S1378
  • [30] Dosimetric evaluation of an atlas-based synthetic CT generation approach for MR-only radiotherapy of pelvis anatomy
    Farjam, Reza
    Tyag, Neelam
    Deasy, Joseph O.
    Hun, Margie A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 101 - 109