Preliminary development of a non-contact method for thermal characterization of building walls: Laboratory evaluation

被引:1
|
作者
Evangelisti, Luca [1 ]
De Cristo, Edoardo [1 ,2 ]
Guattari, Claudia [3 ]
Gori, Paola [1 ]
De Rubeis, Tullio [4 ]
Monteleone, Salvatore [2 ]
机构
[1] Roma Tre Univ, Dept Ind Elect & Mech Engn, Via Vito Volterra 62, I-00146 Rome, Italy
[2] Niccolo Cusano Univ, Dept Engn, Via Don Carlo Gnocchi 3, I-00166 Rome, Italy
[3] Roma Tre Univ, Dept Philosophy, Commun & Performing Arts, Via Ostiense 139, I-00154 Rome, Italy
[4] Univ Aquila, Dept Civil Construct Architectural & Environm Engn, Piazzale Ernesto Pontieri, I-67100 Laquila, Italy
关键词
Heat-flux estimation; Thermometric method; Non-destructive test; Data post-processing; Contactless approach; ACCURACY;
D O I
10.1016/j.csite.2025.106012
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work provides a preliminary experimental investigation with a laboratory setup for proposing a novel enhanced thermometric method, for the thermal characterization of building walls, utilizing a non-contact approach based on infrared thermometry. The goal is a non-invasive application in building diagnostics, particularly in heritage and architecturally sensitive contexts. This study aims to investigate two issues: (i) testing a procedure to automatically process data for determining suitable heat transfer coefficients when calculating heat fluxes when the thermometric method is applied; (ii) understanding the role of infrared thermometers in replacing contact temperature sensors in a proposed enhanced version of the thermometric method for heat flux calculation. Heat fluxes acquired through a commonly used sensor were compared with those computed through the proposed method based on convective and radiative heat transfer assessments. The findings validate the viability of the indirect procedure for calculating heat flux. However, discrepancies in surface temperature measurements were observed between contact and infrared sensors, with differences below 0.5 degrees C. This suggests that infrared thermometers may require careful consideration as they can underestimate surface temperatures, potentially necessitating corrections to obtain heat flux values comparable to those from conventional heat flux sensors.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Non-Contact, In-Line Thermal Characterization Capability with Time Domain Thermoreflectance
    Mair, Robin
    Antonelli, G. Andrew
    Mehendale, Manjusha
    Mukundhan, Priya
    May, Beth
    Terry, Karen
    Brandt, Nathaniel
    Huang, Xiaoyue Phillip
    Zhao, Tong
    2022 33RD ANNUAL SEMI ADVANCED SEMICONDUCTOR MANUFACTURING CONFERENCE (ASMC), 2022,
  • [42] Development of a non-contact method of measuring river depth from the air
    Okamoto, Y
    ENVIRONMENTAL HYDRAULICS, 1999, : 965 - 970
  • [43] Development for non-contact displacement test method and its application verification
    Chen, G. (gxc6307@163.com), 1600, Editorial Board of Journal of Basic Science and (21):
  • [44] Differential laser flash Raman spectroscopy method for non-contact characterization of thermal transport properties of individual nanowires
    Liu, Jinhui
    Liu, Hao
    Hu, Yudong
    Zhang, Xing
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 135 : 511 - 516
  • [45] Non-contact measurement of thermal diffusivity in tissue
    Telenkov, SA
    Youn, JI
    Goodman, DM
    Welch, AJ
    Milner, TE
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 551 - 558
  • [46] Non-contact methods for thermal properties measurement
    Abad, B.
    Borca-Tasciuc, D. -A.
    Martin-Gonzalez, M. S.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 76 : 1348 - 1370
  • [47] A non-contact mixing method for liquids in micro-space (development of a non-contact mixing device by creating a wave on a free surface)
    Katou, Hajime
    Miyake, Ryou
    Kambara, Katsuhiro
    Kawase, Kazumitsu
    Uchida, Hiroyasu
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2004, 70 (693): : 1208 - 1216
  • [48] A Novel Facial Thermal Feature Extraction Method for Non-Contact Healthcare System
    Wang, Zhi-Hao
    Horng, Gwo-Jiun
    Hsu, Tz-Heng
    Chen, Chao-Chun
    Jong, Gwo-Jia
    IEEE ACCESS, 2020, 8 : 86545 - 86553
  • [49] Preliminary results of non-contact THz imaging of cornea
    Sung, Shijun
    Garritano, James
    Bajwa, Neha
    Deng, Sophie
    Hubschman, Jean-Pierre
    Grundfest, Warren S.
    Taylor, Zachary D.
    TERAHERTZ, RF, MILLIMETER, AND SUBMILLIMETER-WAVE TECHNOLOGY AND APPLICATIONS VIII, 2015, 9362
  • [50] A new and reliable method for non-destructive and non-contact testing of thermal spray coatings
    Florin, C
    INSIGHT, 2000, 42 (09) : 606 - 607