Preliminary development of a non-contact method for thermal characterization of building walls: Laboratory evaluation

被引:1
|
作者
Evangelisti, Luca [1 ]
De Cristo, Edoardo [1 ,2 ]
Guattari, Claudia [3 ]
Gori, Paola [1 ]
De Rubeis, Tullio [4 ]
Monteleone, Salvatore [2 ]
机构
[1] Roma Tre Univ, Dept Ind Elect & Mech Engn, Via Vito Volterra 62, I-00146 Rome, Italy
[2] Niccolo Cusano Univ, Dept Engn, Via Don Carlo Gnocchi 3, I-00166 Rome, Italy
[3] Roma Tre Univ, Dept Philosophy, Commun & Performing Arts, Via Ostiense 139, I-00154 Rome, Italy
[4] Univ Aquila, Dept Civil Construct Architectural & Environm Engn, Piazzale Ernesto Pontieri, I-67100 Laquila, Italy
关键词
Heat-flux estimation; Thermometric method; Non-destructive test; Data post-processing; Contactless approach; ACCURACY;
D O I
10.1016/j.csite.2025.106012
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work provides a preliminary experimental investigation with a laboratory setup for proposing a novel enhanced thermometric method, for the thermal characterization of building walls, utilizing a non-contact approach based on infrared thermometry. The goal is a non-invasive application in building diagnostics, particularly in heritage and architecturally sensitive contexts. This study aims to investigate two issues: (i) testing a procedure to automatically process data for determining suitable heat transfer coefficients when calculating heat fluxes when the thermometric method is applied; (ii) understanding the role of infrared thermometers in replacing contact temperature sensors in a proposed enhanced version of the thermometric method for heat flux calculation. Heat fluxes acquired through a commonly used sensor were compared with those computed through the proposed method based on convective and radiative heat transfer assessments. The findings validate the viability of the indirect procedure for calculating heat flux. However, discrepancies in surface temperature measurements were observed between contact and infrared sensors, with differences below 0.5 degrees C. This suggests that infrared thermometers may require careful consideration as they can underestimate surface temperatures, potentially necessitating corrections to obtain heat flux values comparable to those from conventional heat flux sensors.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] CLINICAL EVALUATION OF NON-CONTACT TONOMETER
    WITTENBERG, S
    JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 1977, 48 (02) : 196 - 207
  • [32] EVALUATION OF AO NON-CONTACT TONOMETER
    POLSE, KA
    JAUREGUI, MJ
    MCCLENDON, J
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1972, 49 (10): : 881 - +
  • [33] Development of a Prototype for Non-contact Keyboard
    Kambayashi, Yasushi
    Ueda, Keita
    Kasahara, Masanari
    Kusano, Tatsumi
    Takimoto, Munehiro
    HUMAN SYSTEMS ENGINEERING AND DESIGN, IHSED2018, 2019, 876 : 299 - 304
  • [34] Development of a Non-Contact Angular Transducer
    Farcas, C.
    Cosma, A.
    Palaghita, N.
    Grama, A.
    Gabor, M. S.
    Tiusan, C.
    2014 IEEE 20TH INTERNATIONAL SYMPOSIUM FOR DESIGN AND TECHNOLOGY IN ELECTRONIC PACKAGING (SIITME), 2014, : 187 - 191
  • [35] Method for the evaluation of 3D non-contact, measurement systems
    Harding, Kevin
    DIMENSIONAL OPTICAL METROLOGY AND INSPECTION FOR PRACTICAL APPLICATIONS, 2011, 8133
  • [36] Non-contact method for directing electrotaxis
    Ahirwar, Dinesh K.
    Nasser, Mohd W.
    Jones, Travis H.
    Sequin, Emily K.
    West, Joseph D.
    Henthorne, Timothy L.
    Javor, Joshua
    Kaushik, Aniruddha M.
    Ganju, Ramesh K.
    Subramaniam, Vish V.
    SCIENTIFIC REPORTS, 2015, 5
  • [37] Non-contact method for directing electrotaxis
    Dinesh K. Ahirwar
    Mohd W. Nasser
    Travis H. Jones
    Emily K. Sequin
    Joseph D. West
    Timothy L. Henthorne
    Joshua Javor
    Aniruddha M. Kaushik
    Ramesh K. Ganju
    Vish V. Subramaniam
    Scientific Reports, 5
  • [38] DEVELOPMENT OF THE PNEUMATIC NON-CONTACT HOLDER
    Tsukiji, T.
    Kondo, R.
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 7, 2019,
  • [39] Development of non-contact laser vibrometer
    Kononov, I.
    Velichko, E.
    Aksenov, E.
    2ND INTERNATIONAL SCHOOL AND CONFERENCE SAINT-PETERSBURG OPEN ON OPTOELECTRONICS, PHOTONICS, ENGINEERING AND NANOSTRUCTURES (SPBOPEN2015), 2015, 643
  • [40] Development of a skin temperature measuring system for non-contact stress evaluation
    Kataoka, H
    Kano, H
    Yoshida, H
    Saijo, A
    Yasuda, M
    Osumi, M
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 940 - 943