Preliminary development of a non-contact method for thermal characterization of building walls: Laboratory evaluation

被引:1
|
作者
Evangelisti, Luca [1 ]
De Cristo, Edoardo [1 ,2 ]
Guattari, Claudia [3 ]
Gori, Paola [1 ]
De Rubeis, Tullio [4 ]
Monteleone, Salvatore [2 ]
机构
[1] Roma Tre Univ, Dept Ind Elect & Mech Engn, Via Vito Volterra 62, I-00146 Rome, Italy
[2] Niccolo Cusano Univ, Dept Engn, Via Don Carlo Gnocchi 3, I-00166 Rome, Italy
[3] Roma Tre Univ, Dept Philosophy, Commun & Performing Arts, Via Ostiense 139, I-00154 Rome, Italy
[4] Univ Aquila, Dept Civil Construct Architectural & Environm Engn, Piazzale Ernesto Pontieri, I-67100 Laquila, Italy
关键词
Heat-flux estimation; Thermometric method; Non-destructive test; Data post-processing; Contactless approach; ACCURACY;
D O I
10.1016/j.csite.2025.106012
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work provides a preliminary experimental investigation with a laboratory setup for proposing a novel enhanced thermometric method, for the thermal characterization of building walls, utilizing a non-contact approach based on infrared thermometry. The goal is a non-invasive application in building diagnostics, particularly in heritage and architecturally sensitive contexts. This study aims to investigate two issues: (i) testing a procedure to automatically process data for determining suitable heat transfer coefficients when calculating heat fluxes when the thermometric method is applied; (ii) understanding the role of infrared thermometers in replacing contact temperature sensors in a proposed enhanced version of the thermometric method for heat flux calculation. Heat fluxes acquired through a commonly used sensor were compared with those computed through the proposed method based on convective and radiative heat transfer assessments. The findings validate the viability of the indirect procedure for calculating heat flux. However, discrepancies in surface temperature measurements were observed between contact and infrared sensors, with differences below 0.5 degrees C. This suggests that infrared thermometers may require careful consideration as they can underestimate surface temperatures, potentially necessitating corrections to obtain heat flux values comparable to those from conventional heat flux sensors.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Non-contact ultrasonic imaging for the quantitative and noninvasive evaluation of thermal injury
    Jones, JP
    Lee, D
    Iraniha, S
    Bhardwaj, M
    VanderKam, V
    Achauer, B
    ACOUSTICAL IMAGING, VOL 25, 2000, 25 : 389 - 394
  • [22] Estimating the Thermal Properties of Flat Products by a New Non-contact Method
    Michalak, Marina
    Wiecek, Boguslaw
    FIBRES & TEXTILES IN EASTERN EUROPE, 2008, 16 (04) : 72 - 77
  • [23] Estimating the thermal properties of flat products by a new non-contact method
    Department of Fibre Physics and Textile Metrology, Technical University of Lódź Poland, ul. Zeromskiego 115, 90-543 Lódź, Poland
    不详
    Fibres Text. East. Eur., 2008, 4 (72-77):
  • [24] Non-destructive and non-contact materials evaluation by means of the optodynamic method
    Hrovatin, R
    Mozina, J
    INSIGHT, 2000, 42 (12) : 801 - 804
  • [25] Non-destructive and non-contact materials evaluation by means of the optodynamic method
    Hrovatin, R.
    Mozina, J.
    Insight: Non-Destructive Testing and Condition Monitoring, 2000, 42 (12): : 801 - 808
  • [26] Non-contact characterization of MEMS dynamics
    Dräbenstedt, A
    Heimes, F
    Hettwer, D
    Rembe, C
    Steger, H
    Wörtge, M
    TM-TECHNISCHES MESSEN, 2005, 72 (11) : 601 - 608
  • [27] Non-contact microwave material characterization
    Glay, D
    Lasri, T
    Mamouni, A
    Leroy, Y
    SUBSURFACE AND SURFACE SENSING TECHNOLOGIES AND APPLICATIONS III, 2001, 4491 : 270 - 279
  • [28] Preliminary Experiment on Development of Non-Contact Measuring Method of Arc Potential -Simultaneous Measurement of Potential and Radius-
    Minami, S.
    Yokomizu, Y.
    Matsumura, T.
    Majima, A.
    Uchii, T.
    Suzuki, K.
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 795 - 798
  • [29] Non-contact electrochemical evaluation of biofilms
    Turick, Charles E.
    Colon-Mercado, Hector
    Bagwell, Christopher E.
    Greenway, Scott D.
    Amoroso, Jake W.
    SN APPLIED SCIENCES, 2020, 2 (03):
  • [30] Non-contact electrochemical evaluation of biofilms
    Charles E. Turick
    Hector Colon-Mercado
    Christopher E. Bagwell
    Scott D. Greenway
    Jake W. Amoroso
    SN Applied Sciences, 2020, 2