Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7 T

被引:0
|
作者
Ji, Yang [1 ,2 ]
Woods, Joseph G. [1 ]
Li, Hongwei [1 ,3 ]
Okell, Thomas W. [1 ]
机构
[1] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, FMRIB Div, Oxford, England
[2] Univ Sci & Technol China, Sch Informat Sci & Technol, Dept Elect Engn & Informat Sci, Hefei, Peoples R China
[3] Fudan Univ, Inst Sci & Technol Brain Inspired Intelligence, Shanghai, Peoples R China
基金
英国惠康基金; 中国国家自然科学基金;
关键词
7; T; B0; inhomogeneity; dynamic B0 field shimming; pseudo-continuous arterial spin labeling (PCASL); OFF-RESONANCE; PERFUSION; QUANTIFICATION; INVERSION; ROBUST;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeB0 field inhomogeneity within the brain-feeding arteries is a major issue for pseudo-continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel-specific dynamic B0 field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off-resonance within the arteries in the labeling region.MethodsWe implemented a PCASL sequence with dynamic B0 shimming at 7 T that compensates for B0 field offsets in the brain-feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses. Rapidly acquired vessel-specific B0 field maps were used to calculate dynamic B0 shimming parameters. We evaluated both 2D and 3D variants of our method, comparing their performance against the established global frequency offset and optimal encoding scheme-based corrections. Cerebral blood flow (CBF) maps were quantified before and after corrections, and CBF values from different methods were compared across the whole brain, white matter, and gray matter regions.ResultsAll off-resonance correction methods significantly recovered perfusion signals across the brain. The proposed vessel-specific dynamic B0 shimming method improved the labeling efficiency while maintaining optimal static shimming in the imaging region. Perfusion-weighted images demonstrated the superiority of the 3D dynamic B0 shimming method compared to global or 2D-based correction approaches. CBF analysis revealed that 3D dynamic B0 shimming significantly increased CBF values relative to the other methods.ConclusionOur proposed dynamic B0 shimming method offers a significant advancement in PCASL robustness and effectiveness, enabling full utilization of 7 T ASL high sensitivity and spatial resolution.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Cerebral perfusion alterations in patients with trigeminal neuralgia as measured by pseudo-continuous arterial spin labeling
    Zhou, Qianling
    Li, Meng
    Fan, Qisen
    Chen, Feng
    Jiang, Guihua
    Wang, Tianyue
    He, Qinmeng
    Fu, Shishun
    Yin, Yi
    Lin, Jinzhi
    Yan, Jianhao
    FRONTIERS IN NEUROSCIENCE, 2022, 16
  • [42] High-Resolution Mouse Kidney Perfusion Imaging by Pseudo-Continuous Arterial Spin Labeling at 11.75T
    Duhamel, Guillaume
    Prevost, Valentin
    Girard, Olivier M.
    Callot, Virginie
    Cozzone, Patrick J.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (03) : 1186 - 1196
  • [43] Pseudo-continuous arterial spin labeling MRI study of patients with obsessive-compulsive disorder
    Ota, Miho
    Kanie, Ayako
    Kobayashi, Yuki
    Nakajima, Aiichiro
    Sato, Noriko
    Horikoshi, Masaru
    PSYCHIATRY RESEARCH-NEUROIMAGING, 2020, 303
  • [44] HEART VESSELS - Pseudo-continuous arterial Spin Labeling detects Splenic Switch-Off
    Krome, Susanne
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2024, 196 (04): : 339 - 340
  • [45] Feasibility of Using Pseudo-Continuous Arterial Spin Labeling Perfusion in a Geriatric Population at 1.5 Tesla
    Sigurdsson, Sigurdur
    Forsberg, Lars
    Aspelund, Thor
    van der Geest, Rob J.
    van Buchem, Mark A.
    Launer, Lenore J.
    Gudnason, Vilmundur
    van Osch, Matthias J.
    PLOS ONE, 2015, 10 (12):
  • [46] Model-based super-resolution reconstruction for pseudo-continuous Arterial Spin Labeling
    Beirinckx, Quinten
    Bladt, Piet
    van der Plas, Merlijn C. E.
    van Osch, Matthias J. P.
    Jeurissen, Ben
    den Dekker, Arnold J.
    Sijbers, Jan
    NEUROIMAGE, 2024, 286
  • [47] Effect of background suppression and motion correction on pseudo-continuous arterial spin labeling CBF measurement
    Ibaraki, M.
    Nakamura, K.
    Toyoshima, H.
    Takahashi, K.
    Matsubara, K.
    Pfeuffer, J.
    Kuribayashi, H.
    Kinoshita, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 : 359 - 360
  • [48] Pseudo-continuous arterial spin labeling technique for measuring CBF dynamics with high temporal resolution
    Silva, AC
    Kim, SG
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (03) : 425 - 429
  • [49] Neural plasticity secondary to carpal tunnel syndrome: a pseudo-continuous arterial spin labeling study
    Xue Deng
    Phoebe Lai-Heung Chau
    Suk-Yee Chiu
    Kwok-Pui Leung
    Yong Hu
    Wing-Yuk Ip
    NeuralRegenerationResearch, 2021, 16 (01) : 158 - 165
  • [50] Localized B0 shimming based on 23Na MRI at 7 T
    Gast, Lena, V
    Henning, Anke
    Hensel, Bernhard
    Uder, Michael
    Nagel, Armin M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (04) : 1339 - 1347