Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7 T

被引:0
|
作者
Ji, Yang [1 ,2 ]
Woods, Joseph G. [1 ]
Li, Hongwei [1 ,3 ]
Okell, Thomas W. [1 ]
机构
[1] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, FMRIB Div, Oxford, England
[2] Univ Sci & Technol China, Sch Informat Sci & Technol, Dept Elect Engn & Informat Sci, Hefei, Peoples R China
[3] Fudan Univ, Inst Sci & Technol Brain Inspired Intelligence, Shanghai, Peoples R China
基金
英国惠康基金; 中国国家自然科学基金;
关键词
7; T; B0; inhomogeneity; dynamic B0 field shimming; pseudo-continuous arterial spin labeling (PCASL); OFF-RESONANCE; PERFUSION; QUANTIFICATION; INVERSION; ROBUST;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeB0 field inhomogeneity within the brain-feeding arteries is a major issue for pseudo-continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel-specific dynamic B0 field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off-resonance within the arteries in the labeling region.MethodsWe implemented a PCASL sequence with dynamic B0 shimming at 7 T that compensates for B0 field offsets in the brain-feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses. Rapidly acquired vessel-specific B0 field maps were used to calculate dynamic B0 shimming parameters. We evaluated both 2D and 3D variants of our method, comparing their performance against the established global frequency offset and optimal encoding scheme-based corrections. Cerebral blood flow (CBF) maps were quantified before and after corrections, and CBF values from different methods were compared across the whole brain, white matter, and gray matter regions.ResultsAll off-resonance correction methods significantly recovered perfusion signals across the brain. The proposed vessel-specific dynamic B0 shimming method improved the labeling efficiency while maintaining optimal static shimming in the imaging region. Perfusion-weighted images demonstrated the superiority of the 3D dynamic B0 shimming method compared to global or 2D-based correction approaches. CBF analysis revealed that 3D dynamic B0 shimming significantly increased CBF values relative to the other methods.ConclusionOur proposed dynamic B0 shimming method offers a significant advancement in PCASL robustness and effectiveness, enabling full utilization of 7 T ASL high sensitivity and spatial resolution.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Time-encoded pseudo-continuous arterial spin labeling: Increasing SNR in ASL dynamic angiography
    Woods, Joseph G.
    Schauman, S. Sophie
    Chiew, Mark
    Chappell, Michael A.
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1323 - 1341
  • [22] Requirements for static and dynamic higher order B0 shimming of the human breast at 7 T
    Boer, Vincent O.
    Luttje, Mariska P.
    Luijten, Peter R.
    Klomp, Dennis W. J.
    NMR IN BIOMEDICINE, 2014, 27 (06) : 625 - 631
  • [23] Characterization of Skull Base Lesions Using Pseudo-Continuous Arterial Spin Labeling
    Geerts, B.
    Leclercq, D.
    du Montcel, S. Tezenas
    Law-ye, B.
    Gerber, S.
    Bernardeschi, D.
    Galanaud, D.
    Dormont, D.
    Pyatigorskaya, N.
    CLINICAL NEURORADIOLOGY, 2019, 29 (01) : 75 - 86
  • [24] Selective multivessel labeling approach for perfusion territory imaging in pseudo-continuous arterial spin labeling
    Helle, Michael
    Ruefer, Susanne
    van Osch, Matthias J. P.
    Jansen, Olav
    Norris, David G.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 214 - 219
  • [25] Investigation of control scans in pseudo-continuous arterial spin labeling (pCASL): Strategies for improving sensitivity and reliability of pCASL
    Han, Paul Kyu
    Choi, Seung Hong
    Park, Sung-Hong
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (03) : 917 - 929
  • [26] Measurement of brain perfusion in newborns: Pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL)
    Boudes, Elodie
    Gilbert, Guillaume
    Leppert, Ilana Ruth
    Tan, Xianming
    Pike, G. Bruce
    Saint-Martin, Christine
    Wintermark, Pia
    NEUROIMAGE-CLINICAL, 2014, 6 : 126 - 133
  • [27] Pseudo-continuous arterial spin labeling at 7 T for human brain: Estimation and correction for off-resonance effects using a Prescan
    Luh, Wen-Ming
    Talagala, S. Lalith
    Li, Tie-Qiang
    Bandettini, Peter A.
    MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (02) : 402 - 410
  • [28] Real-Time Functional MRI Using Pseudo-Continuous Arterial Spin Labeling
    Hernandez-Garcia, Luis
    Jahanian, Hesamoddin
    Greenwald, Mark K.
    Zubieta, Jon-Kar
    Peltier, Scott J.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1570 - 1577
  • [29] Optimisation of pulsed and pseudo-continuous arterial spin labeling MRI techniques: A phantom study
    Yusoff, Norain
    Zukhi, Jihan
    Rusli, Awatif
    Zainon, Rafidah
    10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [30] Whole-Cerebrum distortion-free three-dimensional pseudo-continuous arterial spin labeling at 7T
    Zhao, Chenyang
    Shao, Xingfeng
    Shou, Qinyang
    Ma, Samantha J.
    Gokyar, Sayim
    Graf, Christina
    Stollberger, Rudolf
    Wang, Danny J. J.
    NEUROIMAGE, 2023, 277