Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7 T

被引:0
|
作者
Ji, Yang [1 ,2 ]
Woods, Joseph G. [1 ]
Li, Hongwei [1 ,3 ]
Okell, Thomas W. [1 ]
机构
[1] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, FMRIB Div, Oxford, England
[2] Univ Sci & Technol China, Sch Informat Sci & Technol, Dept Elect Engn & Informat Sci, Hefei, Peoples R China
[3] Fudan Univ, Inst Sci & Technol Brain Inspired Intelligence, Shanghai, Peoples R China
基金
英国惠康基金; 中国国家自然科学基金;
关键词
7; T; B0; inhomogeneity; dynamic B0 field shimming; pseudo-continuous arterial spin labeling (PCASL); OFF-RESONANCE; PERFUSION; QUANTIFICATION; INVERSION; ROBUST;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeB0 field inhomogeneity within the brain-feeding arteries is a major issue for pseudo-continuous arterial spin labeling (PCASL) at 7 T because it reduces the labeling efficiency and leads to a loss of perfusion signal. This study aimed to develop a vessel-specific dynamic B0 field shimming method for 7 T PCASL to improve the labeling efficiency by correcting off-resonance within the arteries in the labeling region.MethodsWe implemented a PCASL sequence with dynamic B0 shimming at 7 T that compensates for B0 field offsets in the brain-feeding arteries by updating linear shimming terms and adding a phase increment to the PCASL RF pulses. Rapidly acquired vessel-specific B0 field maps were used to calculate dynamic B0 shimming parameters. We evaluated both 2D and 3D variants of our method, comparing their performance against the established global frequency offset and optimal encoding scheme-based corrections. Cerebral blood flow (CBF) maps were quantified before and after corrections, and CBF values from different methods were compared across the whole brain, white matter, and gray matter regions.ResultsAll off-resonance correction methods significantly recovered perfusion signals across the brain. The proposed vessel-specific dynamic B0 shimming method improved the labeling efficiency while maintaining optimal static shimming in the imaging region. Perfusion-weighted images demonstrated the superiority of the 3D dynamic B0 shimming method compared to global or 2D-based correction approaches. CBF analysis revealed that 3D dynamic B0 shimming significantly increased CBF values relative to the other methods.ConclusionOur proposed dynamic B0 shimming method offers a significant advancement in PCASL robustness and effectiveness, enabling full utilization of 7 T ASL high sensitivity and spatial resolution.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7T
    Ji, Yang
    Woods, Joseph G.
    Li, Hongwei
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (04) : 1674 - 1689
  • [2] Optimization of pseudo-continuous arterial spin labeling at 7T with parallel transmission B1 shimming
    Wang, Kai
    Ma, Samantha J.
    Shao, Xingfeng
    Zhao, Chenyang
    Shou, Qinyang
    Yan, Lirong
    Wang, Danny J. J.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 249 - 262
  • [3] Dynamic B0 shimming at 7 T
    Sengupta, Saikat
    Welch, E. Brian
    Zhao, Yansong
    Foxall, David
    Starewicz, Piotr
    Anderson, Adam W.
    Gore, John C.
    Avison, Malcolm J.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (04) : 483 - 496
  • [4] B0 field inhomogeneity considerations in pseudo-continuous arterial spin labeling (pCASL): effects on tagging efficiency and correction strategy
    Jahanian, Hesamoddin
    Noll, Douglas C.
    Hernandez-Garcia, Luis
    NMR IN BIOMEDICINE, 2011, 24 (10) : 1202 - 1209
  • [5] Hybrid B1+-shimming and gradient adaptions for improved pseudo-continuous arterial spin labeling at 7 Tesla
    Meixner, Christian R.
    Eisen, Christian K.
    Schmitter, Sebastian
    Muller, Max
    Herrler, Juergen
    Hensel, Bernhard
    Doerfler, Arnd
    Uder, Michael
    Nagel, Armin M.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 207 - 219
  • [6] Superselective pseudo-continuous arterial spin labeling angiography
    Jensen-Kondering, Ulf
    Lindner, Thomas
    van Osch, Matthias J. P.
    Rohr, Axel
    Jansen, Olav
    Helle, Michael
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (09) : 1758 - 1767
  • [7] Optimization of adiabatic pulses for pulsed arterial spin labeling at 7 tesla: Comparison with pseudo-continuous arterial spin labeling
    Wang, Kai
    Shao, Xingfeng
    Yan, Lirong
    Ma, Samantha J.
    Jin, Jin
    Wang, Danny J. J.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3227 - 3240
  • [8] AN EXPERIMENTAL INVESTIGATION OF LABELING EFFICIENCY FOR PSEUDO-CONTINUOUS ARTERIAL SPIN LABELING
    Chai, Yaqiong
    Bush, Adam
    Coloigner, Julie
    Qu, Xiaoping
    Chia, Jonathan
    Lepore, Natasha
    Wood, John
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 1101 - 1104
  • [9] In vivo B0 field shimming methods for MRI at 7 T
    Stockmann, Jason P.
    Wald, Lawrence L.
    NEUROIMAGE, 2018, 168 : 71 - 87
  • [10] Characterization of Pseudo-Continuous Arterial Spin Labeling: Simulations and Experimental Validation
    Lorenz, Kathrin
    Mildner, Toralf
    Schlumm, Torsten
    Moeller, Harald E.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (03) : 1638 - 1649