An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy

被引:0
|
作者
Morita, Yugo [1 ,2 ]
Kuriyama, Shinichi [1 ]
Yamawaki, Yusuke [1 ]
Nakamura, Shinichiro [1 ]
Nishitani, Kohei [1 ]
Ito, Hiromu [3 ]
Matsuda, Shuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, 54 Kawahara Cho,Sakyo Ku, Kyoto 6068507, Japan
[2] Hayashi Hosp, Dept Orthopaed Surg, Fukui, Japan
[3] Kurashiki Cent Hosp, Dept Orthopaed Surg, Okayama, Japan
来源
KNEE | 2025年 / 52卷
关键词
Open-wedge high tibial osteotomy; Anatomical artificial bone implant; Synthetic bone substitute; Correction accuracy; Principal component analysis; Statistical shape modeling; PHOSPHATE GRANULES; KNEE ARTHROPLASTY; SLOPE; NAVIGATION; ROTATION; GEOMETRY; PLATEAU; SHAPE; SIZE; GAP;
D O I
10.1016/j.knee.2024.10.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: An anatomical artificial bone implant inserted into the osteotomy gap might be useful for accurate alignment correction during open-wedge high tibial osteotomy (OWHTO). The aims of this study were to evaluate morphological variation in the osteotomy surface, identify an anatomical implant's shape, and verify its usefulness for accurate three-dimensional (3D) correction. Methods: Virtual OWHTO was performed with preoperative 3D computed tomography data from 100 knees. The tibial contour in the osteotomy plane was analyzed using principal component analysis to determine implant shape. An anatomical artificial bone implant with a 10 degrees correction angle was made with a synthetic bone substitute. Coronal correction accuracy and changes in posterior tibial slope (PTS) and rotation were evaluated on eight cadaver knees that received the anatomical artificial bone implant and clinically on 85 in vivo knees that received conventional wedge-shaped spacers. Results: The single-shape anatomical artificial bone implant was designed to occupy a posteromedial 30 x 25 mm region and had high contour congruency (mean mismatch, 0.73 mm; mean contact area coverage, 97.5%). Gap opening angle with the anatomical artificial bone implant was precise, avoiding excessive PTS change (mean, 0.6 degrees) and rotational change (mean, 0.5 degrees). In contrast, both PTS and rotational change with conventional spacers increased by a mean of 2.9 degrees. Conclusions: An anatomical artificial bone implant derived from the mean shape of 100 knees had high and consistent contour congruency. The anatomical artificial bone implant inserted with 3D surgical guidance provided accurate gap opening, reducing PTS change to less than 1 degrees during OWHTO. (c) 2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI
引用
收藏
页码:78 / 89
页数:12
相关论文
共 50 条
  • [41] PRECISION OF NAVIGATED AND CONVENTIONAL OPEN-WEDGE HIGH TIBIAL OSTEOTOMY IN A CADAVER STUDY
    Luetzner, J.
    Gross, A. F.
    Guenther, K. P.
    Kirschner, S.
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2010, 15 (03) : 117 - 120
  • [42] The best position of bone grafts in the medial open-wedge high tibial osteotomy: A finite element analysis
    Pan, Chen-shuai
    Wang, Xiao
    Ding, Ling-zhi
    Zhu, Xian-ping
    Xu, Wei-fang
    Huang, Li-xin
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 228
  • [43] Tranexamic acid is effective for blood management in open-wedge high tibial osteotomy
    Kim, Kang-Il
    Kim, Hwan Jin
    Kim, Gi Beom
    Bae, Seong Hae
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (07) : 1003 - 1007
  • [44] Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy
    Lee, Yong Seuk
    Kim, Min Gyu
    Byun, Hae Won
    Kim, Sang Bum
    Kim, Jin Goo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 846 - 851
  • [45] Tranexamic Acid Is Beneficial to Patients Undergoing Open-Wedge High Tibial Osteotomy
    Chen, De-Sheng
    Zhu, Jia-Wang
    Wang, Tong-Fu
    Zhu, Bo
    Feng, Cai-Hong
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [46] Biomechanical study of three-dimensional printed filler block design in open wedge high tibial osteotomy
    Zhang, Jing
    Zhang, Jianing
    Guo, Lei
    Chen, Shibin
    Jin, Zhongmin
    Chen, Zhenxian
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2024, 41 (04): : 758 - 765
  • [47] Early full weight bearing is safe in open-wedge high tibial osteotomy
    Brinkman, Justus-Martijn
    Luites, Joan W. H.
    Wymenga, Ate B.
    van Heerwaarden, Ronald J.
    ACTA ORTHOPAEDICA, 2010, 81 (02) : 193 - 198
  • [48] Total knee arthroplasty conversion after open-wedge high tibial osteotomy: A report of three cases
    Kim, Hee-June
    Kim, Young-Gun
    Min, Seung-Gi
    Kyung, Hee-Soo
    KNEE, 2016, 23 (06): : 1164 - 1167
  • [49] Open-Wedge High Tibial Osteotomy Using a Protective Cutting System: Technical Advancement for the Accuracy of the Osteotomy and Avoiding Intraoperative Complications
    Lee, Yong Seuk
    Lee, Myung Chul
    Kang, Seo Goo
    Elazab, Ashraf
    Oh, Won Seok
    ARTHROSCOPY TECHNIQUES, 2016, 5 (01): : E7 - E10
  • [50] Control of Posterior Tibial Slope and Patellar Height in Open-Wedge Valgus High Tibial Osteotomy
    Hinterwimmer, Stefan
    Beitzel, Knut
    Paul, Jochen
    Kirchhoff, Chlodwig
    Sauerschnig, Martin
    von Eisenhart-Rothe, Ruediger
    Imhoff, Andreas B.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (04): : 851 - 856