An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy

被引:0
|
作者
Morita, Yugo [1 ,2 ]
Kuriyama, Shinichi [1 ]
Yamawaki, Yusuke [1 ]
Nakamura, Shinichiro [1 ]
Nishitani, Kohei [1 ]
Ito, Hiromu [3 ]
Matsuda, Shuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, 54 Kawahara Cho,Sakyo Ku, Kyoto 6068507, Japan
[2] Hayashi Hosp, Dept Orthopaed Surg, Fukui, Japan
[3] Kurashiki Cent Hosp, Dept Orthopaed Surg, Okayama, Japan
来源
KNEE | 2025年 / 52卷
关键词
Open-wedge high tibial osteotomy; Anatomical artificial bone implant; Synthetic bone substitute; Correction accuracy; Principal component analysis; Statistical shape modeling; PHOSPHATE GRANULES; KNEE ARTHROPLASTY; SLOPE; NAVIGATION; ROTATION; GEOMETRY; PLATEAU; SHAPE; SIZE; GAP;
D O I
10.1016/j.knee.2024.10.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: An anatomical artificial bone implant inserted into the osteotomy gap might be useful for accurate alignment correction during open-wedge high tibial osteotomy (OWHTO). The aims of this study were to evaluate morphological variation in the osteotomy surface, identify an anatomical implant's shape, and verify its usefulness for accurate three-dimensional (3D) correction. Methods: Virtual OWHTO was performed with preoperative 3D computed tomography data from 100 knees. The tibial contour in the osteotomy plane was analyzed using principal component analysis to determine implant shape. An anatomical artificial bone implant with a 10 degrees correction angle was made with a synthetic bone substitute. Coronal correction accuracy and changes in posterior tibial slope (PTS) and rotation were evaluated on eight cadaver knees that received the anatomical artificial bone implant and clinically on 85 in vivo knees that received conventional wedge-shaped spacers. Results: The single-shape anatomical artificial bone implant was designed to occupy a posteromedial 30 x 25 mm region and had high contour congruency (mean mismatch, 0.73 mm; mean contact area coverage, 97.5%). Gap opening angle with the anatomical artificial bone implant was precise, avoiding excessive PTS change (mean, 0.6 degrees) and rotational change (mean, 0.5 degrees). In contrast, both PTS and rotational change with conventional spacers increased by a mean of 2.9 degrees. Conclusions: An anatomical artificial bone implant derived from the mean shape of 100 knees had high and consistent contour congruency. The anatomical artificial bone implant inserted with 3D surgical guidance provided accurate gap opening, reducing PTS change to less than 1 degrees during OWHTO. (c) 2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI
引用
收藏
页码:78 / 89
页数:12
相关论文
共 50 条
  • [31] Comparison of Anatomical Conformity between TomoFix Anatomical Plate and TomoFix Conventional Plate in Open-Wedge High Tibial Osteotomy
    Lee, Sung-Sahn
    Park, Jaesung
    Lee, Dae-Hee
    MEDICINA-LITHUANIA, 2022, 58 (08):
  • [32] Osteotomy configuration of the proximal wedge and analysis of the affecting factors in the medial open-wedge high tibial osteotomy
    Yong Seuk Lee
    Jong Yeal Kang
    Myung Chul Lee
    Ashraf Elazab
    Uk Hyun Choi
    Seo Goo Kang
    Kyoung Jae Lee
    Sahnghoon Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 793 - 799
  • [33] Open wedge high tibial osteotomy using three-dimensional printed models: Experimental analysis using porcine bone
    Kwun, Jun-Dae
    Kim, Hee-June
    Park, Jaeyoung
    Park, Il-Hyung
    Kyung, Hee-Soo
    KNEE, 2017, 24 (01): : 16 - 22
  • [34] Analysis of changes in tibial torsion angle on open-wedge high tibial osteotomy depending on the osteotomy level
    In-Soo Song
    Junhan Kwon
    Knee Surgery & Related Research, 34
  • [35] Analysis of changes in tibial torsion angle on open-wedge high tibial osteotomy depending on the osteotomy level
    Song, In-Soo
    Kwon, Junhan
    KNEE SURGERY & RELATED RESEARCH, 2022, 34 (01)
  • [36] Open-wedge high tibial osteotomy in patients with discoid lateral meniscus
    Kim, Hee-June
    Shin, Ji-Yeon
    Lee, Hyun-Joo
    Jung, Chul-Hee
    Park, Kyeong-Hyeon
    Oh, Chang-Wug
    Kyung, Hee-Soo
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (02)
  • [37] Osteotomy configuration of the proximal wedge and analysis of the affecting factors in the medial open-wedge high tibial osteotomy
    Lee, Yong Seuk
    Kang, Jong Yeal
    Lee, Myung Chul
    Elazab, Ashraf
    Choi, Uk Hyun
    Kang, Seo Goo
    Lee, Kyoung Jae
    Lee, Sahnghoon
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (03) : 793 - 799
  • [38] Posteromedial Open-Wedge High Tibial Osteotomy to Avoid Posterior Tibial Slope Increase
    Kaya, Huseyin
    Dastan, Ali Engin
    Bicer, Elcil Kaya
    Taskiran, Emin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (10): : 2710 - 2717
  • [39] Effect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis
    Han, Seung-Beom
    Kim, Hyun Jung
    Lee, Dae-Hee
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [40] Difference of preoperative varus–valgus stress radiograph is effective for the correction accuracy in the preoperative planning during open-wedge high tibial osteotomy
    Ji Eui Kim
    Dong Hyun Kim
    Jae Ik Lee
    Han Gyeol Choi
    You Sun Jung
    Sang Hoon Lee
    Yong Seuk Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2021, 29 : 1035 - 1044