An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy

被引:0
|
作者
Morita, Yugo [1 ,2 ]
Kuriyama, Shinichi [1 ]
Yamawaki, Yusuke [1 ]
Nakamura, Shinichiro [1 ]
Nishitani, Kohei [1 ]
Ito, Hiromu [3 ]
Matsuda, Shuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, 54 Kawahara Cho,Sakyo Ku, Kyoto 6068507, Japan
[2] Hayashi Hosp, Dept Orthopaed Surg, Fukui, Japan
[3] Kurashiki Cent Hosp, Dept Orthopaed Surg, Okayama, Japan
来源
KNEE | 2025年 / 52卷
关键词
Open-wedge high tibial osteotomy; Anatomical artificial bone implant; Synthetic bone substitute; Correction accuracy; Principal component analysis; Statistical shape modeling; PHOSPHATE GRANULES; KNEE ARTHROPLASTY; SLOPE; NAVIGATION; ROTATION; GEOMETRY; PLATEAU; SHAPE; SIZE; GAP;
D O I
10.1016/j.knee.2024.10.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: An anatomical artificial bone implant inserted into the osteotomy gap might be useful for accurate alignment correction during open-wedge high tibial osteotomy (OWHTO). The aims of this study were to evaluate morphological variation in the osteotomy surface, identify an anatomical implant's shape, and verify its usefulness for accurate three-dimensional (3D) correction. Methods: Virtual OWHTO was performed with preoperative 3D computed tomography data from 100 knees. The tibial contour in the osteotomy plane was analyzed using principal component analysis to determine implant shape. An anatomical artificial bone implant with a 10 degrees correction angle was made with a synthetic bone substitute. Coronal correction accuracy and changes in posterior tibial slope (PTS) and rotation were evaluated on eight cadaver knees that received the anatomical artificial bone implant and clinically on 85 in vivo knees that received conventional wedge-shaped spacers. Results: The single-shape anatomical artificial bone implant was designed to occupy a posteromedial 30 x 25 mm region and had high contour congruency (mean mismatch, 0.73 mm; mean contact area coverage, 97.5%). Gap opening angle with the anatomical artificial bone implant was precise, avoiding excessive PTS change (mean, 0.6 degrees) and rotational change (mean, 0.5 degrees). In contrast, both PTS and rotational change with conventional spacers increased by a mean of 2.9 degrees. Conclusions: An anatomical artificial bone implant derived from the mean shape of 100 knees had high and consistent contour congruency. The anatomical artificial bone implant inserted with 3D surgical guidance provided accurate gap opening, reducing PTS change to less than 1 degrees during OWHTO. (c) 2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI
引用
收藏
页码:78 / 89
页数:12
相关论文
共 50 条
  • [21] Applicability of a modified angular correction measurement method for open-wedge high tibial osteotomy
    James Moore
    Lydia Mychaltchouk
    Frédéric Lavoie
    Knee Surgery, Sports Traumatology, Arthroscopy, 2017, 25 : 846 - 852
  • [22] The degree of correction in open-wedge high tibial osteotomy compromises bone healing: A consecutive review of 101 cases
    Dornacher, Daniel
    Leitz, Franziska
    Kappe, Thomas
    Reichel, Heiko
    Faschingbauer, Martin
    KNEE, 2021, 29 : 478 - 485
  • [23] Effect of the amount of correction on posterior tibial slope and patellar height in open-wedge high tibial osteotomy
    Wu, Keliang
    Zeng, Jianchun
    Han, Linjing
    Feng, Wenjun
    Lin, Xiaosheng
    Zeng, Yirong
    JOURNAL OF ORTHOPAEDIC SURGERY, 2021, 29 (03)
  • [24] The Evaluation of Knee Bone Mineral Density Following Open-Wedge High Tibial Osteotomy
    Kosior, Piotr
    Czuraszkiewicz, Lukasz
    Tarczynska, Marta
    Mazurkiewicz, Tomasz
    Gaweda, Krzysztof
    JOURNAL OF APPLIED BIOMECHANICS, 2012, 28 (04) : 359 - 365
  • [25] Autologous Osteophyte Grafting for Open-Wedge High Tibial Osteotomy
    Akiyama, Takenori
    Okazaki, Ken
    Mawatari, Taro
    Ikemura, Satoshi
    Nakamura, Shunsuke
    ARTHROSCOPY TECHNIQUES, 2016, 5 (05): : E989 - E995
  • [26] Three-dimensional analysis of lateral cortical hinge in medial open-wedge high tibial osteotomy: A computational simulation study of adult cadavers
    Jung, Gu-Hee
    Lee, Kyung-Ho
    Wang, Lih
    JOURNAL OF ORTHOPAEDIC SURGERY, 2020, 28 (03)
  • [27] Precise, computed-assisted leg angle correction with open-wedge high tibial osteotomy
    Hart, R.
    Stipcak, V.
    Kucera, B.
    Filan, P.
    deCordeiro, J.
    ORTHOPADE, 2007, 36 (06): : 577 - 581
  • [28] Kirschner Wire Reference Technique in Open-Wedge High Tibial Osteotomy
    Kwanyuang, Atichart
    Boonriong, Tanarat
    Parinyakhup, Wachiraphan
    Chuaychoosakoon, Chaiwat
    ARTHROSCOPY TECHNIQUES, 2021, 10 (06): : E1543 - E1546
  • [29] Effect of the Osteotomy Inclination Angle in the Sagittal Plane on the Posterior Tibial Slope of the Tibiofemoral Joint in Medial Open-Wedge High Tibial Osteotomy: Three-Dimensional Computed Tomography Analysis
    Chung, Jai Hyun
    Choi, Chong Hyuk
    Kim, Sung-Hwan
    Kim, Sung-Jae
    Lee, Seung-Kyu
    Jung, Min
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (18)
  • [30] Open-wedge high tibial osteotomy with special medial plate fixator
    Lobenhoffer, P
    Agneskirchner, J
    Zoch, W
    ORTHOPADE, 2004, 33 (02): : 153 - +