An anatomical artificial bone implant can improve three-dimensional correction accuracy in open-wedge high tibial osteotomy

被引:0
|
作者
Morita, Yugo [1 ,2 ]
Kuriyama, Shinichi [1 ]
Yamawaki, Yusuke [1 ]
Nakamura, Shinichiro [1 ]
Nishitani, Kohei [1 ]
Ito, Hiromu [3 ]
Matsuda, Shuichi [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Orthopaed Surg, 54 Kawahara Cho,Sakyo Ku, Kyoto 6068507, Japan
[2] Hayashi Hosp, Dept Orthopaed Surg, Fukui, Japan
[3] Kurashiki Cent Hosp, Dept Orthopaed Surg, Okayama, Japan
来源
KNEE | 2025年 / 52卷
关键词
Open-wedge high tibial osteotomy; Anatomical artificial bone implant; Synthetic bone substitute; Correction accuracy; Principal component analysis; Statistical shape modeling; PHOSPHATE GRANULES; KNEE ARTHROPLASTY; SLOPE; NAVIGATION; ROTATION; GEOMETRY; PLATEAU; SHAPE; SIZE; GAP;
D O I
10.1016/j.knee.2024.10.017
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: An anatomical artificial bone implant inserted into the osteotomy gap might be useful for accurate alignment correction during open-wedge high tibial osteotomy (OWHTO). The aims of this study were to evaluate morphological variation in the osteotomy surface, identify an anatomical implant's shape, and verify its usefulness for accurate three-dimensional (3D) correction. Methods: Virtual OWHTO was performed with preoperative 3D computed tomography data from 100 knees. The tibial contour in the osteotomy plane was analyzed using principal component analysis to determine implant shape. An anatomical artificial bone implant with a 10 degrees correction angle was made with a synthetic bone substitute. Coronal correction accuracy and changes in posterior tibial slope (PTS) and rotation were evaluated on eight cadaver knees that received the anatomical artificial bone implant and clinically on 85 in vivo knees that received conventional wedge-shaped spacers. Results: The single-shape anatomical artificial bone implant was designed to occupy a posteromedial 30 x 25 mm region and had high contour congruency (mean mismatch, 0.73 mm; mean contact area coverage, 97.5%). Gap opening angle with the anatomical artificial bone implant was precise, avoiding excessive PTS change (mean, 0.6 degrees) and rotational change (mean, 0.5 degrees). In contrast, both PTS and rotational change with conventional spacers increased by a mean of 2.9 degrees. Conclusions: An anatomical artificial bone implant derived from the mean shape of 100 knees had high and consistent contour congruency. The anatomical artificial bone implant inserted with 3D surgical guidance provided accurate gap opening, reducing PTS change to less than 1 degrees during OWHTO. (c) 2024 Elsevier B.V. All rights are reserved, including those for text and data mining, AI
引用
收藏
页码:78 / 89
页数:12
相关论文
共 50 条
  • [1] Evaluation of Accuracy of a Three-Dimensional Printed Model in Open-Wedge High Tibial Osteotomy
    Kim, Hee-June
    Park, Jaeyeong
    Park, Kyeong-Hyeon
    Park, Il-Hyung
    Jang, Jin-An
    Shin, Ji-Yeon
    Kyung, Hee-Soo
    JOURNAL OF KNEE SURGERY, 2019, 32 (09) : 841 - 846
  • [2] More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy
    Hee-June Kim
    Jaeyeong Park
    Ji-Yeon Shin
    Il-Hyung Park
    Kyeong-Hyeon Park
    Hee-Soo Kyung
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 3452 - 3458
  • [3] More accurate correction can be obtained using a three-dimensional printed model in open-wedge high tibial osteotomy
    Kim, Hee-June
    Park, Jaeyeong
    Shin, Ji-Yeon
    Park, Il-Hyung
    Park, Kyeong-Hyeon
    Kyung, Hee-Soo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (11) : 3452 - 3458
  • [4] Accuracy of frontal and sagittal plane correction in open-wedge high tibial osteotomy
    Marti, CB
    Gautier, E
    Wachtl, SW
    Jakob, RP
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2004, 20 (04): : 366 - 372
  • [5] Development of an educational three-dimensional anatomical structure replication tool and its application to medial open-wedge high tibial osteotomy
    Takatsume, Yoshifumi
    Nakase, Junsuke
    Oshima, Takeshi
    Kanayama, Tomoyuki
    Imanishi, Nobuaki
    Tsuchiya, Hiroyuki
    KNEE, 2023, 44 : 150 - 157
  • [6] Validation of Computer-assisted Open-wedge High Tibial Osteotomy Using Three-dimensional Navigation
    Yamamoto, Yuji
    Ishibashi, Yasuyuki
    Tsuida, Eiichi
    Tsukada, Harehiko
    Kimura, Yuka
    Toh, Satoshi
    ORTHOPEDICS, 2008, 31 (10) : 68 - 71
  • [7] Three-Dimensional Printed Customized Scaffolds Covered with Decellularized Bone Extracellular Matrix for Open-Wedge High-Tibial Osteotomy
    Ahn, Geunseon
    Kim, Jun-Young
    Shim, Jin-Hyung
    An, Sang-Hyun
    Kim, Junsik
    Kim, Changhwan
    Lee, In-Gyu
    Shin, Jung-Min
    Lee, Byunghoon
    BIOENGINEERING-BASEL, 2024, 11 (11):
  • [8] Validation of a Three-Dimensional Weight-Bearing Measurement Protocol for Medial Open-Wedge High Tibial Osteotomy
    Hodel, Sandro
    Hasler, Julian
    Roth, Tabitha Arn
    Flury, Andreas
    Sutter, Cyrill
    Fucentese, Sandro F.
    Fuernstahl, Philipp
    Vlachopoulos, Lazaros
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (05)
  • [9] Change in leg length after open-wedge high tibial osteotomy can be predicted from the opening width: A three-dimensional analysis
    Yamamuro, Yuki
    Kabata, Tamon
    Goshima, Kenichi
    Kajino, Yoshitomo
    Inoue, Daisuke
    Ohmori, Takaaki
    Ueno, Takuro
    Takagi, Tomoharu
    Yoshitani, Junya
    Ueoka, Ken
    Taninaka, Atsushi
    Tsuchiya, Hiroyuki
    KNEE, 2021, 30 : 185 - 194
  • [10] No correction angle loss with stable plates in open-wedge high tibial osteotomy
    Min Kyu Kim
    Jeong Ku Ha
    Dhong Won Lee
    Sang Wook Nam
    Jin Goo Kim
    Yong Seuk Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1999 - 2006