Effect of a prototype 2-dimensional antiscatter grid on image quality obtained with a dental cone-beam computed tomography scanner

被引:0
|
作者
Li, Boyuan [1 ,2 ]
Somerkivi, Villeseveri [3 ,4 ,5 ]
Bayat, Farhang [6 ]
Huynh, Carolyn [7 ]
Altunbas, Cem [6 ]
机构
[1] M2 Technol, Denver, CO USA
[2] Stanford Univ, Dept Radiol, Stanford, CA USA
[3] Planmeca, Helsinki, Finland
[4] Tech Univ Munich, Sch Nat Sci, Dept Phys, Garching, Germany
[5] Tech Univ Munich, Munich Inst Biomed Engn, Garching, Germany
[6] Univ Colorado, Dept Radiat Oncol, Sch Med, 1665 Aurora Court Suite 1032, Aurora, CO 80045 USA
[7] UTHealth Houston, Dept Diagnost & Biomed Sci, Sch Dent, Houston, TX USA
关键词
Cone-Beam Computed Tomography; X-rays; Diagnostic Imaging; Image quality enhancement; SCATTER CORRECTION METHODS; GENERAL FRAMEWORK; CT;
D O I
10.5624/isd.20240182
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: X-ray scattering adversely affects cone-beam computed tomography (CBCT) image quality, generating image artifacts, causing inaccurate tissue density representation, and reducing contrast. This study evaluated the performance of a 2-dimensional antiscatter grid (2D grid) prototype in a dental CBCT system. Materials and Methods: A focused 2D grid prototype was fabricated from tungsten and integrated with the detector of a dental CBCT system. Residual scatter transmitted through the 2D grid was corrected using a measurement-based scatter correction method. Phantom imaging experiments were performed in anatomical regions relevant to dental and head imaging with and without this grid. Following image reconstruction via filtered back projection, attenuation coefficients were converted to Hounsfield units (HU). Subsequently, scatter suppression performance, HU consistency, image artifacts, and contrast resolution were evaluated. Results: The 2D grid reduced scatter intensity by a factor of 10-20 in CBCT projections. Consequently, the grid substantially increased contrast, reduced image artifacts, and improved HU consistency. The contrast increased by 27% and 48% in bone- and soft tissue-equivalent regions, respectively. HU value deviations among teeth decreased from 510 to 146 HU. These results indicate improved visualization and tissue density representation fidelity in CBCT images acquired with the 2D grid. Conclusion: Use of a 2D grid could substantially improve the accuracy of tissue density representation and the contrast of dental and head anatomy in 3-dimensional images obtained with dental CBCT. Such improvements may translate to better quantitative evaluation of bone quality, enhanced tissue visualization, and more accurate model generation for surgical planning and guidance. (Imaging Sci Dent 20240182)
引用
收藏
页数:11
相关论文
共 50 条
  • [42] Cone-Beam Computed Tomography: A useful tool for dental age estimation?
    Maret, D.
    Peters, O. A.
    Dedouit, F.
    Telmon, N.
    Sixou, M.
    MEDICAL HYPOTHESES, 2011, 76 (05) : 700 - 702
  • [43] Clinical utility of dental cone-beam computed tomography: current perspectives
    Jaju, Prashant P.
    Jaju, Sushma P.
    CLINICAL COSMETIC AND INVESTIGATIONAL DENTISTRY, 2014, 6 : 29 - 43
  • [44] Is Cone-Beam Computed Tomography Always Necessary for Dental Implant Placement?
    Deeb, George
    Antonos, Ludmils
    Tack, Samuel
    Carrico, Caroline
    Laskin, Daniel
    Deeb, Janina Golob
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 75 (02) : 285 - 289
  • [45] MONTE CARLO DOSE ASSESSMENT IN DENTAL CONE-BEAM COMPUTED TOMOGRAPHY
    Kim, Jinwoo
    Jeon, Hosang
    Kim, Ho Kyung
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 190 - 199
  • [46] Analysis of the effect of cone-beam geometry and test object configuration on the measurement accuracy of a computed tomography scanner used for dimensional measurement
    Kumar, Jagadeesha
    Attridge, Alex
    Wood, P. K. C.
    Williams, Mark A.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (03)
  • [47] A Prototype of Cone-Beam Breast Computed Tomography System and its Performance Evaluation
    Xiao, Dayu
    Xu, Lisheng
    Qi, Shouliang
    Yao, Yupeng
    Kang, Yan
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 66 - 69
  • [48] A phantom for simplified image quality control of dental cone beam computed tomography units
    Torgersen, Gerald R.
    Hol, Caroline
    Moystad, Anne
    Hellen-Halme, Kristina
    Nilsson, Mats
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2014, 118 (05): : 603 - 611
  • [49] Effect of a Motion Artifact Correction System on Cone-Beam Computed Tomography Image Characteristics
    Pahadia, Mayank
    Katkar, Rujuta
    Geha, Hassem
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [50] Image quality and dose for a multisource cone-beam CT extremity scanner
    Gang, Grace J.
    Zbijewski, Wojciech
    Mahesh, Mahadevappa
    Thawait, Gaurav
    Packard, Nathan
    Yorkston, John
    Demehri, Shadpour
    Siewerdsen, Jeffrey H.
    MEDICAL PHYSICS, 2018, 45 (01) : 144 - 155