Effect of a prototype 2-dimensional antiscatter grid on image quality obtained with a dental cone-beam computed tomography scanner

被引:0
|
作者
Li, Boyuan [1 ,2 ]
Somerkivi, Villeseveri [3 ,4 ,5 ]
Bayat, Farhang [6 ]
Huynh, Carolyn [7 ]
Altunbas, Cem [6 ]
机构
[1] M2 Technol, Denver, CO USA
[2] Stanford Univ, Dept Radiol, Stanford, CA USA
[3] Planmeca, Helsinki, Finland
[4] Tech Univ Munich, Sch Nat Sci, Dept Phys, Garching, Germany
[5] Tech Univ Munich, Munich Inst Biomed Engn, Garching, Germany
[6] Univ Colorado, Dept Radiat Oncol, Sch Med, 1665 Aurora Court Suite 1032, Aurora, CO 80045 USA
[7] UTHealth Houston, Dept Diagnost & Biomed Sci, Sch Dent, Houston, TX USA
关键词
Cone-Beam Computed Tomography; X-rays; Diagnostic Imaging; Image quality enhancement; SCATTER CORRECTION METHODS; GENERAL FRAMEWORK; CT;
D O I
10.5624/isd.20240182
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: X-ray scattering adversely affects cone-beam computed tomography (CBCT) image quality, generating image artifacts, causing inaccurate tissue density representation, and reducing contrast. This study evaluated the performance of a 2-dimensional antiscatter grid (2D grid) prototype in a dental CBCT system. Materials and Methods: A focused 2D grid prototype was fabricated from tungsten and integrated with the detector of a dental CBCT system. Residual scatter transmitted through the 2D grid was corrected using a measurement-based scatter correction method. Phantom imaging experiments were performed in anatomical regions relevant to dental and head imaging with and without this grid. Following image reconstruction via filtered back projection, attenuation coefficients were converted to Hounsfield units (HU). Subsequently, scatter suppression performance, HU consistency, image artifacts, and contrast resolution were evaluated. Results: The 2D grid reduced scatter intensity by a factor of 10-20 in CBCT projections. Consequently, the grid substantially increased contrast, reduced image artifacts, and improved HU consistency. The contrast increased by 27% and 48% in bone- and soft tissue-equivalent regions, respectively. HU value deviations among teeth decreased from 510 to 146 HU. These results indicate improved visualization and tissue density representation fidelity in CBCT images acquired with the 2D grid. Conclusion: Use of a 2D grid could substantially improve the accuracy of tissue density representation and the contrast of dental and head anatomy in 3-dimensional images obtained with dental CBCT. Such improvements may translate to better quantitative evaluation of bone quality, enhanced tissue visualization, and more accurate model generation for surgical planning and guidance. (Imaging Sci Dent 20240182)
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Measurement of the MTF of a Cone-Beam Breast Computed Tomography Laboratory Scanner
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Lauria, Adele
    Russo, Paolo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3958 - 3964
  • [22] Measurement of the MTF of a Cone-Beam Breast Computed Tomography Laboratory Scanner
    Mettivier, Giovanni
    Russo, Paolo
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (03) : 703 - 713
  • [23] Correlation analysis between radiation exposure and the image quality of cone-beam computed tomography in the dental clinical environment
    Song, Chang-Ho
    Yeom, Han-Gyeol
    Kim, Jo-Eun
    Huh, Kyung-Hoe
    Yi, Won-Jin
    Heo, Min-Suk
    Lee, Sam-Sun
    IMAGING SCIENCE IN DENTISTRY, 2022, : 283 - 288
  • [24] Clinical applications of cone-beam computed tomography in dental practice
    Scarfe, William C.
    Farman, Allan G.
    Sukovic, Predag
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2006, 72 (01): : 75 - 80
  • [25] Reliability and accuracy of cone-beam computed tomography dental measurements
    Baumgaertel, Sebastian
    Palomo, J. Martin
    Palomo, Leena
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 19 - 25
  • [26] Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions
    Jiang, Tingting
    Lee, Sang-Mi
    Hou, Yanan
    Chang, Xin
    Hwang, Hyeon-Shik
    KOREAN JOURNAL OF ORTHODONTICS, 2016, 46 (03) : 129 - 136
  • [27] A NEWLY DEVELOPED PHANTOM FOR PHYSICAL QUALITY ASSURANCE OF DENTAL CONE-BEAM COMPUTED TOMOGRAPHY
    Bamba, Junko
    Ishida, Hideki
    Araki, Kazuyuki
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (03) : 303 - 311
  • [28] An audit of image quality of three dental cone beam computed tomography units
    Greenall, C. J.
    Thomas, B.
    Drage, N. A.
    Brown, J.
    RADIOGRAPHY, 2016, 22 (01) : 56 - 59
  • [29] Dose and Image Quality of Cone-Beam Computed Tomography as Compared With Conventional Multislice Computed Tomography in Abdominal Imaging
    Schegerer, Alexander A.
    Lechel, Ursula
    Ritter, Manuel
    Weisser, Gerald
    Fink, Christian
    Brix, Gunnar
    INVESTIGATIVE RADIOLOGY, 2014, 49 (10) : 675 - 684
  • [30] Effect of diagnostic cone-beam computed tomography protocols on image quality, patient dose, and lesion detection
    Paul, Jijo
    Chacko, Annamma
    Saccomandi, Paola
    Vogl, Thomas J.
    Nour-Eldin, Nour-Eldin A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (12): : 1575 - 1583