Effect of a prototype 2-dimensional antiscatter grid on image quality obtained with a dental cone-beam computed tomography scanner

被引:0
|
作者
Li, Boyuan [1 ,2 ]
Somerkivi, Villeseveri [3 ,4 ,5 ]
Bayat, Farhang [6 ]
Huynh, Carolyn [7 ]
Altunbas, Cem [6 ]
机构
[1] M2 Technol, Denver, CO USA
[2] Stanford Univ, Dept Radiol, Stanford, CA USA
[3] Planmeca, Helsinki, Finland
[4] Tech Univ Munich, Sch Nat Sci, Dept Phys, Garching, Germany
[5] Tech Univ Munich, Munich Inst Biomed Engn, Garching, Germany
[6] Univ Colorado, Dept Radiat Oncol, Sch Med, 1665 Aurora Court Suite 1032, Aurora, CO 80045 USA
[7] UTHealth Houston, Dept Diagnost & Biomed Sci, Sch Dent, Houston, TX USA
关键词
Cone-Beam Computed Tomography; X-rays; Diagnostic Imaging; Image quality enhancement; SCATTER CORRECTION METHODS; GENERAL FRAMEWORK; CT;
D O I
10.5624/isd.20240182
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: X-ray scattering adversely affects cone-beam computed tomography (CBCT) image quality, generating image artifacts, causing inaccurate tissue density representation, and reducing contrast. This study evaluated the performance of a 2-dimensional antiscatter grid (2D grid) prototype in a dental CBCT system. Materials and Methods: A focused 2D grid prototype was fabricated from tungsten and integrated with the detector of a dental CBCT system. Residual scatter transmitted through the 2D grid was corrected using a measurement-based scatter correction method. Phantom imaging experiments were performed in anatomical regions relevant to dental and head imaging with and without this grid. Following image reconstruction via filtered back projection, attenuation coefficients were converted to Hounsfield units (HU). Subsequently, scatter suppression performance, HU consistency, image artifacts, and contrast resolution were evaluated. Results: The 2D grid reduced scatter intensity by a factor of 10-20 in CBCT projections. Consequently, the grid substantially increased contrast, reduced image artifacts, and improved HU consistency. The contrast increased by 27% and 48% in bone- and soft tissue-equivalent regions, respectively. HU value deviations among teeth decreased from 510 to 146 HU. These results indicate improved visualization and tissue density representation fidelity in CBCT images acquired with the 2D grid. Conclusion: Use of a 2D grid could substantially improve the accuracy of tissue density representation and the contrast of dental and head anatomy in 3-dimensional images obtained with dental CBCT. Such improvements may translate to better quantitative evaluation of bone quality, enhanced tissue visualization, and more accurate model generation for surgical planning and guidance. (Imaging Sci Dent 20240182)
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Antiscatter grids in mobile C-arm cone-beam CT: Effect on image quality and dose
    Schafer, S.
    Stayman, J. W.
    Zbijewski, W.
    Schmidgunst, C.
    Kleinszig, G.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2012, 39 (01) : 153 - 159
  • [32] Image analysis and superimposition of 3-dimensional cone-beam computed tomography models
    Cevidanes, Lucia H. S.
    Styner, Martin A.
    Proffit, William R.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 129 (05) : 611 - 618
  • [33] Feasibility of a Pre-Object-Grid to Reduce Scatter and Improve Image Quality in Cone-Beam Computed Tomography (CBCT)
    Jin, J.
    Liu, Q.
    Kim, J.
    Wen, N.
    Movsas, B.
    Chetty, I.
    MEDICAL PHYSICS, 2009, 36 (06) : 2475 - +
  • [34] Tilting the jaw to improve the image quality or to reduce the dose in cone-beam computed tomography
    Luckow, Marlen
    Deyhle, Hans
    Beckmann, Felix
    Dagassan-Berndt, Dorothea
    Mueller, Bert
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E389 - E393
  • [35] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    De Cock, Jens
    Zanca, Federica
    Canning, John
    Pauwels, Ruben
    Hermans, Robert
    EUROPEAN RADIOLOGY, 2015, 25 (07) : 1891 - 1900
  • [36] A comparative study for image quality and radiation dose of a cone beam computed tomography scanner and a multislice computed tomography scanner for paranasal sinus imaging
    Jens De Cock
    Federica Zanca
    John Canning
    Ruben Pauwels
    Robert Hermans
    European Radiology, 2015, 25 : 1891 - 1900
  • [37] Detection of dental root fractures by using cone-beam computed tomography
    Wang, P.
    Yan, X. B.
    Lui, D. G.
    Zhang, W. L.
    Zhang, Y.
    Ma, X. C.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (05) : 290 - 298
  • [38] Evaluation of Dental Root Fracture Using Cone-beam Computed Tomography
    Wang, Pei
    Yan, Xue Bing
    Liu, Deng Gao
    Zhang, Wan Lin
    Zhang, Zu Yan
    Ma, Xu Chen
    CHINESE JOURNAL OF DENTAL RESEARCH, 2010, 13 (01): : 31 - 35
  • [39] Cone-beam computed tomography and its applications in dental and maxillofacial radiology
    Schulze, R. K. W.
    Drage, N. A.
    CLINICAL RADIOLOGY, 2020, 75 (09) : 647 - 657
  • [40] Dental Cone-Beam Computed Tomography: Are the Eye Lens and Thyroid at Risk?
    Albahiti, Sarah K.
    Jadu, Fatima M.
    Badr, Fatma
    Khalifa, Hanadi
    Khan, Emad
    Khafaji, Mawya
    INTERNATIONAL JOURNAL OF BIOMEDICINE, 2024, 14 (01) : 77 - 82