Cylindrically bent Laue analyzer in an X-ray Raman/emission spectrometer: performance tests and a comparison with spherically bent Bragg analyzers

被引:1
|
作者
Hiraoka, Nozomu [1 ]
机构
[1] Natl Synchrotron Radiat Res Ctr, Hsinchu 30076, Taiwan
关键词
X-ray Raman scattering; X-ray emission spectroscopy; Laue analyzers; spherically bent Bragg analyzers; cylindrically bent Laue analyzers; INELASTIC-SCATTERING EXPERIMENTS; RAMAN-SCATTERING; SPECTROSCOPY; DESIGN; EXAFS; ID20;
D O I
10.1107/S1600577524010634
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The performances of a spherically bent Bragg analyzer and a cylindrically bent Laue analyzer in an X-ray Raman/emission spectrometer are compared. The reflectivity and energy resolution are evaluated from the intensity of the elastic scattering and the width of the energy distribution on a SiO2 glass sample. Widely used, Bragg analyzers display excellent performance at the photon energy E <= 10 keV. However, at higher E, the reflectivity and the resolution gradually deteriorate as E increases, showing poor performance above 20 keV. On the other hand, the reflectivity of the Laue analyzer gradually increases at E > 10 keV, displaying excellent reflectivity and good resolution around 20 keV. The Laue analyzer is suitable for X-ray absorption spectroscopy in high-energy-resolution fluorescence-detection mode or X-ray emission spectroscopy on 4d transition metal compounds. Furthermore, the X-ray Raman features of the lithium K-edge in LiF and the oxygen K-edge feature in H2O, measured by nine Bragg analyzers (2 m radius) at E similar or equal to 9.9 keV and by five Laue analyzers (1.4 m radius) at E similar or equal to 19.5 keV, have been compared. Similar count rates and resolutions are observed.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 50 条
  • [41] X-ray diffraction efficiency of bent GaAs mosaic crystals for the Laue project
    Ferrari, Claudio
    Buffagni, Elisa
    Bonnini, Elisa
    Zappettini, Andrea
    OPTICAL ENGINEERING, 2014, 53 (04)
  • [42] Bent perfect crystals as X-ray focusing polychromators in symmetric Laue geometry
    Guigay, J. -P.
    Ferrero, C.
    Bhattacharyya, D.
    Mathon, O.
    Pascarelli, S.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2013, 69 : 91 - 97
  • [43] APPLICATION OF A BENT-CRYSTAL X-RAY SPECTROMETER TO ANALYSIS OF EMISSION OUTSIDE ROWLAND CIRCLE
    TRAPEZNI.VA
    SAPOZHNI.VP
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (03): : 897 - &
  • [44] Research of asymmetric Bragg X-ray diffraction in an elastically bent crystal
    Molodkin, VB
    Shevchenko, MB
    Pobydajlo, OV
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 2002, 24 (05): : 639 - 652
  • [45] Bent Bragg-Fresnel lenses for x-ray imaging diagnostics
    Aglitskiy, Y
    Obenschain, S
    Yunkin, V
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 2228 - 2231
  • [46] Laboratory characterization of bent monocrystal wafers for Bragg X-ray spectroscopy
    Stefan Płocieniak
    Żaneta Szaforz
    Experimental Astronomy, 2018, 45 : 255 - 268
  • [47] DESIGN OF A BENT CRYSTAL X-RAY SPECTROMETER FOR MEASUREMENT OF X-RAY CHEMICAL-SHIFTS
    JOSEPHSO.WD
    ROBERTS, LD
    KNOBLE, DW
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1972, 17 (02): : 194 - &
  • [48] A bent silicon crystal in the Laue geometry to resolve actinide x-ray fluorescence for x-ray absorption spectroscopy
    Kropf, A. J.
    Fortner, J. A.
    Finch, R. J.
    Cunnane, J. C.
    Karanfil, C.
    PHYSICA SCRIPTA, 2005, T115 : 998 - 1000
  • [49] Laboratory characterization of bent monocrystal wafers for Bragg X-ray spectroscopy
    Plocieniak, Stefan
    Szaforz, Zaneta
    EXPERIMENTAL ASTRONOMY, 2018, 45 (02) : 255 - 268
  • [50] Calculation of the Johann error for spherically bent x-ray imaging crystal spectrometers
    Wang, E.
    Beiersdorfer, P.
    Gu, M.
    Bitter, M.
    Delgado-Aparicio, L.
    Hill, K. W.
    Reinke, M.
    Rice, J. E.
    Podpaly, Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):