Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review

被引:1
|
作者
Prisco, Giuseppe [1 ]
Pirozzi, Maria Agnese [2 ]
Santone, Antonella [1 ]
Esposito, Fabrizio [2 ]
Cesarelli, Mario [3 ]
Amato, Francesco [4 ]
Donisi, Leandro [2 ]
机构
[1] Univ Molise, Dept Med & Hlth Sci, I-86100 Campobasso, Italy
[2] Univ Campania Luigi Vanvitelli, Dept Adv Med & Surg Sci, I-80138 Naples, Italy
[3] Univ Sannio, Dept Engn, I-82100 Benevento, Italy
[4] Univ Naples Federico II, Dept Informat Technol & Elect Engn, I-80125 Naples, Italy
关键词
agreement; biomechanics; gait analysis; inertial measurement units; wearable sensors; VALIDATION; ACCELEROMETER; PARAMETERS; KINEMATICS; GYROSCOPE; EVENTS; MOTION;
D O I
10.3390/diagnostics15010036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis. Methods: This review examined English studies between 2012 and 2023, retrieved from the Scopus database, comparing wearable sensors to optical motion capture systems, focusing on IMU body placement, gait parameters, and validation metrics. Exclusion criteria for the search included conference papers, reviews, unavailable papers, studies without wearable inertial sensors for gait analysis, and those not involving agreement studies or optical motion capture systems. Results: From an initial pool of 479 articles, 32 were selected for full-text screening. Among them, the lower body resulted in the most common site for single IMU placement (in 22 studies), while the most frequently used multi-sensor configuration involved IMU positioning on the lower back, shanks, feet, and thighs (10 studies). Regarding gait parameters, 11 studies out of the 32 included studies focused on spatial-temporal parameters, 12 on joint kinematics, 2 on gait events, and the remainder on a combination of parameters. In terms of validation metrics, 24 studies employed correlation coefficients as the primary measure, while 7 studies used a combination of error metrics, correlation coefficients, and Bland-Altman analysis. Validation metrics revealed that IMUs exhibited good to moderate agreement with optical motion capture systems for kinematic measures. In contrast, spatiotemporal parameters demonstrated greater variability, with agreement ranging from moderate to poor. Conclusions: This review highlighted the transformative potential of wearable IMUs in advancing gait analysis beyond the constraints of traditional laboratory-based systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [41] A Systematic Review of Performance Analysis in Rowing Using Inertial Sensors
    Worsey, Matthew T. O.
    Espinosa, Hugo G.
    Shepherd, Jonathan B.
    Thiel, David, V
    ELECTRONICS, 2019, 8 (11)
  • [42] Wearable sensors used for human gait analysis
    Tarnita, Daniela
    ROMANIAN JOURNAL OF MORPHOLOGY AND EMBRYOLOGY, 2016, 57 (02): : 373 - 382
  • [43] A dataset for wearable sensors validation in gait analysis
    Pierleoni, Paola
    Pinti, Federica
    Belli, Alberto
    Palma, Lorenzo
    DATA IN BRIEF, 2020, 31
  • [44] VALIDITY OF WEARABLE SENSORS IN EVALUATING POST-STROKE GAIT QUALITY
    Hodgins, A.
    Manning, O.
    Wang, L. Ei
    Li, Q.
    DePaul, V.
    Brouwer, B.
    INTERNATIONAL JOURNAL OF STROKE, 2018, 13 : 206 - 206
  • [45] Gait asymmetrical evaluation of lower limb amputees using wearable inertial sensors
    Maqbool, Hafiz Farhan
    Mahmood, Imran
    Ali, Ahmad
    Iqbal, Nadeem
    Seong, Jin-Taek
    Dehghani-Sanij, Abbas Ali
    Alaziz, Sundas Naji
    Awad, Mohammed Ibrahim
    HELIYON, 2024, 10 (12)
  • [46] Wearable inertial sensors provide reliable biomarkers of disease severity in multiple sclerosis: A systematic review and meta-analysis
    Vienne-Jumeau, Alienor
    Quijoux, Flavien
    Vidal, Pierre-Paul
    Ricard, Damien
    ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2020, 63 (02) : 138 - 147
  • [47] The Use of Wearable Inertial Motion Sensors in Human Lower Limb Biomechanics Studies: A Systematic Review
    Fong, Daniel Tik-Pui
    Chan, Yue-Yan
    SENSORS, 2010, 10 (12) : 11556 - 11565
  • [48] Indirect Measurement of Ground Reaction Forces and Moments by Means of Wearable Inertial Sensors: A Systematic Review
    Ancillao, Andrea
    Tedesco, Salvatore
    Barton, John
    O'Flynn, Brendan
    SENSORS, 2018, 18 (08)
  • [49] Freezing of gait and fall detection in Parkinson’s disease using wearable sensors: a systematic review
    Ana Lígia Silva de Lima
    Luc J. W. Evers
    Tim Hahn
    Lauren Bataille
    Jamie L. Hamilton
    Max A. Little
    Yasuyuki Okuma
    Bastiaan R. Bloem
    Marjan J. Faber
    Journal of Neurology, 2017, 264 : 1642 - 1654
  • [50] The Contribution of Machine Learning in the Validation of Commercial Wearable Sensors for Gait Monitoring in Patients: A Systematic Review
    Jourdan, Theo
    Debs, Noelie
    Frindel, Carole
    SENSORS, 2021, 21 (14)