Validity of Wearable Inertial Sensors for Gait Analysis: A Systematic Review

被引:1
|
作者
Prisco, Giuseppe [1 ]
Pirozzi, Maria Agnese [2 ]
Santone, Antonella [1 ]
Esposito, Fabrizio [2 ]
Cesarelli, Mario [3 ]
Amato, Francesco [4 ]
Donisi, Leandro [2 ]
机构
[1] Univ Molise, Dept Med & Hlth Sci, I-86100 Campobasso, Italy
[2] Univ Campania Luigi Vanvitelli, Dept Adv Med & Surg Sci, I-80138 Naples, Italy
[3] Univ Sannio, Dept Engn, I-82100 Benevento, Italy
[4] Univ Naples Federico II, Dept Informat Technol & Elect Engn, I-80125 Naples, Italy
关键词
agreement; biomechanics; gait analysis; inertial measurement units; wearable sensors; VALIDATION; ACCELEROMETER; PARAMETERS; KINEMATICS; GYROSCOPE; EVENTS; MOTION;
D O I
10.3390/diagnostics15010036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: Gait analysis, traditionally performed with lab-based optical motion capture systems, offers high accuracy but is costly and impractical for real-world use. Wearable technologies, especially inertial measurement units (IMUs), enable portable and accessible assessments outside the lab, though challenges with sensor placement, signal selection, and algorithm design can affect accuracy. This systematic review aims to bridge the benchmarking gap between IMU-based and traditional systems, validating the use of wearable inertial systems for gait analysis. Methods: This review examined English studies between 2012 and 2023, retrieved from the Scopus database, comparing wearable sensors to optical motion capture systems, focusing on IMU body placement, gait parameters, and validation metrics. Exclusion criteria for the search included conference papers, reviews, unavailable papers, studies without wearable inertial sensors for gait analysis, and those not involving agreement studies or optical motion capture systems. Results: From an initial pool of 479 articles, 32 were selected for full-text screening. Among them, the lower body resulted in the most common site for single IMU placement (in 22 studies), while the most frequently used multi-sensor configuration involved IMU positioning on the lower back, shanks, feet, and thighs (10 studies). Regarding gait parameters, 11 studies out of the 32 included studies focused on spatial-temporal parameters, 12 on joint kinematics, 2 on gait events, and the remainder on a combination of parameters. In terms of validation metrics, 24 studies employed correlation coefficients as the primary measure, while 7 studies used a combination of error metrics, correlation coefficients, and Bland-Altman analysis. Validation metrics revealed that IMUs exhibited good to moderate agreement with optical motion capture systems for kinematic measures. In contrast, spatiotemporal parameters demonstrated greater variability, with agreement ranging from moderate to poor. Conclusions: This review highlighted the transformative potential of wearable IMUs in advancing gait analysis beyond the constraints of traditional laboratory-based systems.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] WEARABLE INERTIAL SENSORS FOR GAIT ANALYSIS IN ADULTS WITH OSTEOARTHRITIS - A SCOPING REVIEW
    Kobsar, D.
    Masood, Z.
    Khan, H.
    Khalil, N.
    Kiwan, M.
    Ridd, S.
    Tobis, M.
    OSTEOARTHRITIS AND CARTILAGE, 2021, 29 : S182 - S183
  • [2] Wearable inertial sensors in swimming motion analysis: a systematic review
    de Magalhaes, Fabricio Anicio
    Vannozzi, Giuseppe
    Gatta, Giorgio
    Fantozzi, Silvia
    JOURNAL OF SPORTS SCIENCES, 2015, 33 (07) : 732 - 745
  • [3] Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
    Chen, Shanshan
    Lach, John
    Lo, Benny
    Yang, Guang-Zhong
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (06) : 1521 - 1537
  • [4] Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis
    Dylan Kobsar
    Jesse M. Charlton
    Calvin T.F. Tse
    Jean-Francois Esculier
    Angelo Graffos
    Natasha M. Krowchuk
    Daniel Thatcher
    Michael A. Hunt
    Journal of NeuroEngineering and Rehabilitation, 17
  • [5] Validity and reliability of wearable inertial sensors in healthy adult walking: a systematic review and meta-analysis
    Kobsar, Dylan
    Charlton, Jesse M.
    Tse, Calvin T. F.
    Esculier, Jean-Francois
    Graffos, Angelo
    Krowchuk, Natasha M.
    Thatcher, Daniel
    Hunt, Michael A.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2020, 17 (01)
  • [6] Wearable Inertial Sensors for Gait Analysis in Adults with Osteoarthritis-A Scoping Review
    Kobsar, Dylan
    Masood, Zaryan
    Khan, Heba
    Khalil, Noha
    Kiwan, Marium Yossri
    Ridd, Sarah
    Tobis, Matthew
    SENSORS, 2020, 20 (24) : 1 - 24
  • [7] Multimodal Gait Analysis based on Wearable Inertial and Microphone Sensors
    Wang, Cheng
    Wang, Xiangdong
    Long, Zhou
    Yuan, Jing
    Qian, Yueling
    Li, Jintao
    2017 IEEE SMARTWORLD, UBIQUITOUS INTELLIGENCE & COMPUTING, ADVANCED & TRUSTED COMPUTED, SCALABLE COMPUTING & COMMUNICATIONS, CLOUD & BIG DATA COMPUTING, INTERNET OF PEOPLE AND SMART CITY INNOVATION (SMARTWORLD/SCALCOM/UIC/ATC/CBDCOM/IOP/SCI), 2017,
  • [8] Evaluation of gait recovery after total knee arthroplasty using wearable inertial sensors: A systematic review
    Gianzina, Elina
    Kalinterakis, Georgios
    Delis, Spilios
    Vlastos, Iakovos
    Sachinis, Nikolaos Platon
    Yiannakopoulos, Christos K.
    KNEE, 2023, 41 : 190 - 203
  • [9] Wearable Inertial Sensors to Assess Gait during the 6-Minute Walk Test: A Systematic Review
    Storm, Fabio Alexander
    Cesareo, Ambra
    Reni, Gianluigi
    Biffi, Emilia
    SENSORS, 2020, 20 (09)
  • [10] A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms
    Caldas, Rafael
    Mundt, Marion
    Potthast, Wolfgang
    de Lima Neto, Fernando Buarque
    Markert, Bernd
    GAIT & POSTURE, 2017, 57 : 204 - 210